Corneal hysteresis and corneal resistance factor in keratoectasia: Findings using the Reichert Ocular Response Analyzer

被引:69
|
作者
Kirwan, Caitriona [1 ,3 ]
O'Malley, Donal [3 ]
O'Keefe, Michael [1 ,2 ,3 ]
机构
[1] Mater Private Hosp, Dublin 7, Ireland
[2] Univ Coll Dublin, Dublin 2, Ireland
[3] Childrens Univ Hosp, Dublin, Ireland
关键词
hysteresis; corneal resistance factor; ocular aberrations;
D O I
10.1159/000145333
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To examine corneal hysteresis (CH) and corneal resistance factor (CRF) in normal and ectatic corneas. Methods: CH and CRF were measured using the Reichert Ocular Response Analyzer in patients with clinically diagnosed keratoconus ( KC), forme fruste KC (FFKC) and normal eyes. Results: 21 eyes ( 13 patients) with clinically diagnosed KC and 30 eyes ( 18 patients) with FFKC were included in the study. Mean CH and CRF in FFKC did not differ from that in pachymetry-matched normal eyes. KC eyes had significantly lower CH and CRF than normal and FFKC eyes. Conclusion: A significant overlap in CH and CRF values among the 3 groups was evident. Our findings do not indicate a role for CH and CRF measurement as a single test to aid in the detection of early ectasia. It may be of use when used in conjunction with other parameters such as aberrometry. CH and CRF values may prove to be useful in monitoring ectasia progression. Copyright (C) 2008 S. Karger AG, Basel.
引用
收藏
页码:334 / 337
页数:4
相关论文
共 50 条
  • [1] Corneal Hysteresis, Corneal Resistance Factor, and Intraocular Pressure Measurement in Patients with Scleroderma Using the Reichert Ocular Response Analyzer
    Emre, Sinan
    Kayikcioglu, Oezcan
    Ates, Halil
    Cinar, Esat
    Inceoglu, Nehir
    Yargucu, Figen
    Pirildar, Timur
    Oksel, Fahrettin
    [J]. CORNEA, 2010, 29 (06) : 628 - 631
  • [2] Corneal hysteresis and intraocular pressure measurement in children using the Reichert Ocular Response Analyzer
    Kirwan, Caitriona
    O'Keefe, Michael
    Lanigan, Bernadette
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (06) : 990 - 992
  • [3] Assessing Corneal Hysteresis Using the Ocular Response Analyzer
    McMonnies, Charles W.
    [J]. OPTOMETRY AND VISION SCIENCE, 2012, 89 (03) : E343 - E349
  • [4] Contact lens effect on corneal hysteresis, IOP and EOP as measured by the Reichert ocular response analyzer
    Luce, D
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U576 - U576
  • [5] Evaluation of corneal biomechanical properties with the Reichert Ocular Response Analyzer
    Detry-Morel, Michele
    Jamart, Jacques
    Pourjavan, Saveh
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (02) : 138 - 148
  • [6] Corneal hysteresis using the Reichert ocular response analyser: findings pre- and post-LASIK and LASEK
    Kirwan, Caitriona
    O'Keefe, Michael
    [J]. ACTA OPHTHALMOLOGICA, 2008, 86 (02) : 215 - 218
  • [7] Corneal hysteresis and intraocular pressure measurement in children using the Reichert ocular response analyzer (vol 142, pg 990, 2006)
    Kirwan, C.
    O'Keefe, M.
    Lanigan, B.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (04) : 642 - 642
  • [8] Relationship between Ocular Rigidity, Corneal Hysteresis, and Corneal Resistance Factor
    Lin, Shuai-Chun
    Kazemi, Arash
    McLaren, Jay W.
    Moroi, Sayoko Eileen
    Toris, Carol B.
    Sit, Arthur J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [9] Relationship Between Corneal Hysteresis and Corneal Resistance Factor with Other Ocular Parameters
    Rosa, Nicola
    Lanza, Michele
    De Bernardo, Maddalena
    Signoriello, Giuseppe
    Chiodini, Paolo
    [J]. SEMINARS IN OPHTHALMOLOGY, 2015, 30 (5-6) : 335 - 339
  • [10] Corneal hysteresis measured with the Ocular Response Analyzer® in normal and glaucomatous eyes
    Abitbol, Olivia
    Bouden, Jihene
    Doan, Serge
    Hoang-Xuan, Thanh
    Gatinel, Damien
    [J]. ACTA OPHTHALMOLOGICA, 2010, 88 (01) : 116 - 119