Measurement of electron density with the phase-resolved cut-off probe method

被引:9
|
作者
Kwon, J. H. [1 ]
You, S. J. [2 ]
Kim, D. W. [1 ]
Na, B. K. [1 ]
Kim, J. H. [2 ]
Shin, Y. H. [2 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Phys, Taejon 305701, South Korea
[2] Korea Res Inst Stand & Sci, Ctr Vacuum Technol, Taejon 305306, South Korea
关键词
PLASMA OSCILLATION METHOD; ENERGY DISTRIBUTION; ABSORPTION PROBE;
D O I
10.1063/1.3586561
中图分类号
O59 [应用物理学];
学科分类号
摘要
The phase resolved cut-off probe method, a precise measurement method for the electron density, was recently proposed [J. H. Kwon et al., Appl. Phys. Lett. 96, 081502 (2010)]. This paper presents the measurements of electron density using the method under various experimental conditions (different pressures, powers, chamber volumes, and discharge sources). The result shows that the method is not only in good agreement with the previous method using wave transmittance under various experimental conditions but it is also able to find the cut-off point clearly even under difficult conditions such as high pressure (similar to 1 Torr), high discharge power, and small plasma volume. The details of the experimental setup, the operating mechanism of the probe method, and the data processing procedure (algorithm) are also addressed. Furthermore, the reliability of the measurement method is investigated by using an electromagnetic field simulation with cold plasma model (CST-Drude model, Computer Simulation Technology). (C) 2011 American Institute of Physics. [doi:10.1063/1.3586561]
引用
收藏
页数:9
相关论文
共 50 条
  • [32] Ultrafast phase-resolved pump-probe measurements on a quantum cascade laser
    Kuehn, W.
    Parz, W.
    Gaal, P.
    Reimann, K.
    Woerner, M.
    Elsaesser, T.
    Mueller, T.
    Darmo, J.
    Unterrainer, K.
    Austerer, M.
    Strasser, G.
    Wilson, L. R.
    Cockburn, J. W.
    Krysa, A. B.
    Roberts, J. S.
    APPLIED PHYSICS LETTERS, 2008, 93 (15)
  • [33] Polyvinylpyrrolidone Quantification in Paracetamol Using Phase-Resolved Photoacoustic Method
    Somer, A.
    Camilotti, J. G.
    Goncalves, A.
    Bonardi, C.
    Cruz, G. K.
    Beltrame, F. L.
    Sato, F.
    Astrath, N. G. C.
    Novatski, A.
    SPECTROSCOPY LETTERS, 2015, 48 (06) : 427 - 430
  • [34] Photoacoustic viscoelasticity detection of biological tissues with phase-resolved method
    Zhao, Yue
    Yang, Sihua
    TENTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE (PIBM 2011), 2012, 8329
  • [35] Phase-resolved optical emission spectroscopy for an electron cyclotron resonance etcher
    Milosavljevic, Vladimir
    MacGearailt, Niall
    Cullen, P. J.
    Daniels, Stephen
    Turner, Miles M.
    JOURNAL OF APPLIED PHYSICS, 2013, 113 (16)
  • [36] A mixed method for determination of cut-off dates in liner shipping
    Caliskan, Aylin
    Ozkan-Ozen, Yesim Deniz
    Chase, Nazlican
    MARITIME POLICY & MANAGEMENT, 2024, 51 (05) : 848 - 866
  • [37] Nuclear Level Density and Spin Cut-off Parameters of Light Nuclei
    Z.Kargar
    A.N.Behkami
    中国核科技报告, 1997, (S2) : 21 - 35
  • [38] Optical density cut-off values for Clostridium difficile enzyme immunoassays
    Goldenberg, S. D.
    Simpson, E.
    French, G. L.
    JOURNAL OF HOSPITAL INFECTION, 2011, 77 (02) : 169 - 170
  • [39] Water cut-off system of mechanical shield docking method
    Watanabe, Toshio
    Hagiwara, Hideki
    Nishitake, Shigeru
    Sugiyama, Masahiko
    Doboku Gakkai Rombun-Hokokushu/Proceedings of the Japan Society of Civil Engineers, 1993, (468 pt 6-19): : 77 - 85
  • [40] A Design Method of Fluency FIR Filters with Steep Cut-Off
    Kawasaki, Shuji
    Katagishi, Kazuki
    Toraichi, Kazuo
    Murakami, Hitomi
    2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 62 - +