The phase resolved cut-off probe method, a precise measurement method for the electron density, was recently proposed [J. H. Kwon et al., Appl. Phys. Lett. 96, 081502 (2010)]. This paper presents the measurements of electron density using the method under various experimental conditions (different pressures, powers, chamber volumes, and discharge sources). The result shows that the method is not only in good agreement with the previous method using wave transmittance under various experimental conditions but it is also able to find the cut-off point clearly even under difficult conditions such as high pressure (similar to 1 Torr), high discharge power, and small plasma volume. The details of the experimental setup, the operating mechanism of the probe method, and the data processing procedure (algorithm) are also addressed. Furthermore, the reliability of the measurement method is investigated by using an electromagnetic field simulation with cold plasma model (CST-Drude model, Computer Simulation Technology). (C) 2011 American Institute of Physics. [doi:10.1063/1.3586561]
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Diagnostics principle of microwave cut-off probe for measuring absolute electron density
    Jun, Hyun-Su
    PHYSICS OF PLASMAS, 2014, 21 (08)
  • [2] Analysis of the uncertainty in the measurement of electron densities in plasmas using the phase-resolved cutoff method
    Kim, Jung-Hyung
    Kwon, J. H.
    You, S. J.
    Seong, Daejin
    Shin, Yong-Hyeon
    METROLOGIA, 2011, 48 (05) : 306 - 310
  • [3] A Study on the Optimal Cut-off Point in the Cut-off Sampling Method
    Lee, Sang Eun
    Cho, Min Ji
    Shin, Key-Il
    KOREAN JOURNAL OF APPLIED STATISTICS, 2014, 27 (03) : 501 - 512
  • [4] Theoretical and experimental study of the microwave cut-off probe for electron density measurements in low-temperature plasmas
    Li, Bin
    Li, Hong
    Wang, Huihui
    Xie, Jinlin
    Liu, Wandong
    JOURNAL OF APPLIED PHYSICS, 2011, 110 (07)
  • [5] Electron cut-off wavelength transistor
    Nimtz, G.
    Marquardt, P.
    Applied Physics A: Solids and Surfaces, 1988, 47 (04): : 317 - 318
  • [6] MEASUREMENT OF CUT-OFF WAVELENGTH IN MONOMODE FIBRES BY A POLARIZATION METHOD.
    Coppa, Gianni
    Di Vita, Pietro
    Rossi, Umberto
    CSELT Technical Reports, 1985, 13 (01): : 61 - 65
  • [7] Spectral cut-off regularisation for density estimation under multiplicative measurement errors
    Miguel, Sergio Brenner
    Comte, Fabienne
    Johannes, Jan
    ELECTRONIC JOURNAL OF STATISTICS, 2021, 15 (01): : 3551 - 3573
  • [8] Infrared cut-off proposal for the holographic density
    Granda, L. N.
    Oliveros, A.
    PHYSICS LETTERS B, 2008, 669 (05) : 275 - 277
  • [9] ELECTRON TRANSPORT IN STRONGLY CUT-OFF MAGNETRON
    HIRSCH, EH
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1967, 22 (04) : 297 - &
  • [10] APPROXIMATION OF PHASE SHIFTS WITH CUT-OFF PARAMETER
    MICHALIK, B
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1968, 18 (04) : 517 - &