Stereotaxic localization and core needle biopsy of nonpalpable breast lesions: Two-year follow-up of a prospective study

被引:0
|
作者
Head, JF
Haynes, AE
Elliott, MC
Elliott, RL
机构
关键词
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
In August 1989, we began a prospective study of patients with abnormal mammograms to determine the clinical efficacy of stereotaxic localization and needle biopsy of nonpalpable breast lesions. By August 1990, 115 patients had undergone stereotaxic localization and needle biopsy of nonpalpable breast lesions using the Mammotest II (Fischer Imaging, Denver, CO) and an 18-gauge needle in a Bard Biopty gun (Bard Urological, Covington, GA). In 19 per cent (22 of 115) of the cases, the pathologist suggested open surgical biopsies of the lesions due to clinical judgment, or atypical or cancer cells in the core biopsy specimen. Of these 22 cases, 12 (54%) were found to be cancer on open surgical biopsy-10 per cent of all the patients. Of the remaining 93 patients with benign pathology, 9 were lost to follow-up by the end of the second year after closure of the study. The remaining 84 patients were followed by mammography and physical exam at 3 months, at 12 months, and yearly thereafter to determine whether cancer had been missed or developed at the biopsy site. The median follow-up was 24 months (mean, 23.3 months), and all 84 patients were found to have no evidence of malignant disease at follow-up. The small group (10 cases) of patients who were determined to have benign disease by open surgical biopsy were also found on follow-up to have no evidence of malignant disease (median follow-up, 20.5 months; and mean, 18.3 months). The accuracy of this stereotaxic procedure, combined with an approximately 80 per cent decrease in the more expensive and more invasive open surgical biopsy procedure, provides strong support for the use of this procedure on all nonpalpable breast lesions that would normally proceed to open surgical biopsy.
引用
收藏
页码:1018 / 1023
页数:6
相关论文
共 50 条
  • [11] NONPALPABLE BREAST-LESIONS - FINDINGS OF STEREOTAXIC NEEDLE-CORE BIOPSY AND FINE-NEEDLE ASPIRATION CYTOLOGY
    DOWLATSHAHI, K
    YAREMKO, ML
    KLUSKENS, LF
    JOKICH, PM
    RADIOLOGY, 1991, 181 (03) : 745 - 750
  • [12] STEREOTAXIC FINE-NEEDLE ASPIRATION BIOPSY FOR NONPALPABLE BREAST-LESIONS
    JACKSON, VP
    BASSETT, LW
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (06) : 1196 - 1197
  • [13] REVIEW OF STEREOTAXIC LARGE-CORE NEEDLE-BIOPSY AND SURGICAL BIOPSY RESULTS IN NONPALPABLE BREAST-LESIONS
    KOPANS, DB
    RADIOLOGY, 1993, 189 (03) : 665 - 666
  • [14] Stereotaxic needle-core biopsy and fine-needle aspiration biopsy in the diagnosis of nonpalpable breast lesions: Controversies and future prospects
    Lifrange, E
    Kridelka, F
    Colin, C
    EUROPEAN JOURNAL OF RADIOLOGY, 1997, 24 (01) : 39 - 47
  • [15] OUTPATIENT NEEDLE LOCALIZATION AND BIOPSY FOR NONPALPABLE BREAST-LESIONS
    HOMER, MJ
    SMITH, TJ
    MARCHANT, DJ
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1984, 252 (17): : 2452 - 2454
  • [16] POST-LOCALIZATION NEEDLE FOR BREAST BIOPSY OF NONPALPABLE LESIONS
    HOMER, MJ
    FISHER, DM
    SUGARMAN, HJ
    RADIOLOGY, 1981, 140 (01) : 241 - 242
  • [17] Large-core needle biopsy of nonpalpable breast lesions
    Meyer, JE
    Smith, DN
    Lester, SC
    Kaelin, C
    DiPiro, PJ
    Denison, CM
    Christian, RL
    Harvey, SC
    Selland, DLG
    Durfee, SM
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 281 (17): : 1638 - 1641
  • [18] TECHNIQUE AND GUIDELINES FOR NEEDLE LOCALIZATION BIOPSY OF NONPALPABLE LESIONS OF THE BREAST
    WILHELM, MC
    WANEBO, HJ
    SURGERY GYNECOLOGY & OBSTETRICS, 1988, 167 (05): : 439 - 441
  • [19] NONPALPABLE BREAST-LESIONS - OUTPATIENT NEEDLE LOCALIZATION AND BIOPSY
    SMITHBEHN, J
    GHANI, A
    POSTGRADUATE MEDICAL JOURNAL, 1987, 63 (735) : 17 - 18
  • [20] REVIEW OF STEREOTAXIC LARGE-CORE NEEDLE-BIOPSY AND SURGICAL BIOPSY RESULTS IN NONPALPABLE BREAST-LESIONS - REPLY
    ELVECROG, EL
    LECHNER, MC
    NELSON, MT
    RADIOLOGY, 1993, 189 (03) : 666 - 666