Predicting electrospray response from chromatographic retention time

被引:124
|
作者
Cech, NB [1 ]
Krone, JR [1 ]
Enke, CG [1 ]
机构
[1] Univ New Mexico, Dept Chem, Albuquerque, NM 87131 USA
关键词
D O I
10.1021/ac0006019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The relationship between electrospray ionization response and HPLC retention time was explored. For the series of small peptides studied, higher ESI response was observed for analytes with longer reversed-phase HPLC retention times. This correlation existed for both experimentally measured retention times and those calculated from amino acid retention coefficients. This study is useful to ESI users since it provides a way to predict and understand anomalies in ESI response with a readily accessible experimental parameter (chromatographic retention time). In addition, the ability to correlate ESI response with chromatographic partitioning lends validity to the equilibrium partitioning model, which explains differences in ESI response on the basis of partitioning between the surface and interior phases of the ESI droplet.
引用
收藏
页码:208 / 213
页数:6
相关论文
共 50 条
  • [41] LOW-RETENTION-TIME GAS CHROMATOGRAPHIC ANALYSIS OF PENTENE ISOMERS
    OTTMERS, DM
    SAY, GR
    RASE, HF
    ANALYTICAL CHEMISTRY, 1966, 38 (01) : 148 - &
  • [42] Correction of retention time shift of components for chromatographic fingerprints of herbal medicine
    Li, BY
    Liang, YZ
    Hu, Y
    Xie, PS
    Yu, RQ
    Li, FM
    Sun, Y
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (03) : 313 - 316
  • [43] Prediction of gas chromatographic retention time via an additive thermodynamic model
    Karolat, Bryan
    Harynuk, James
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (29) : 4862 - 4867
  • [44] Dependence of the width of the chromatographic zone on retention time in capillary gas chromatography
    Berezkin, VG
    Shiryaeva, VE
    Popova, TP
    RUSSIAN CHEMICAL BULLETIN, 1997, 46 (02) : 307 - 308
  • [45] Dependence of the width of the chromatographic zone on retention time in capillary gas chromatography
    V. G. Berezkin
    V. E. Shiryaeva
    T. P. Popova
    Russian Chemical Bulletin, 1997, 46 : 307 - 308
  • [46] A quantitative structure-retention relationship study for prediction of chromatographic relative retention time of chlorinated monoterpenes
    Ghasemi, Jahan B.
    Ahmadi, Sh.
    Brown, S. D.
    ENVIRONMENTAL CHEMISTRY LETTERS, 2011, 9 (01) : 87 - 96
  • [47] An accurate model for predicting retention time of coffee flavor in cigarette
    Si, Hongzong
    Li, Xianchao
    Fu, Aiping
    Yuan, Shuping
    Hao, Ming
    Zhang, Kejun
    Duan, Yun-Bo
    Hu, Zhide
    ADVANCES IN APPLIED SCIENCE AND INDUSTRIAL TECHNOLOGY, PTS 1 AND 2, 2013, 798-799 : 1091 - +
  • [48] A New Combination Strategy as Applied in Predicting Chromatographic Retention Times of Oligonucleotides at a Range of Temperatures from 30 °C to 80 °C
    Liang, Gui-Zhao
    Ma, Xiu-Yan
    Chen, Yu-Zhen
    Li, Yuan-Chao
    Lv, Feng-Li
    Yang, Li
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2011, 58 (01) : 75 - 82
  • [49] RETENTION TIME AND THE FUNCTIONAL-RESPONSE OF BEAVERS
    FRYXELL, JM
    VAMOSI, SM
    WALTON, RA
    DOUCET, CM
    OIKOS, 1994, 71 (02) : 207 - 214
  • [50] Predicting gas chromatographic retention times of 209 polybrominated diphenyls (PBBs) for different temperature programs
    H. X. Zhao
    Q. Zhang
    X. Y. Xue
    X. M. Liang
    A. Kettrup
    Analytical and Bioanalytical Chemistry, 2005, 382 : 1304 - 1310