Predicting electrospray response from chromatographic retention time

被引:124
|
作者
Cech, NB [1 ]
Krone, JR [1 ]
Enke, CG [1 ]
机构
[1] Univ New Mexico, Dept Chem, Albuquerque, NM 87131 USA
关键词
D O I
10.1021/ac0006019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The relationship between electrospray ionization response and HPLC retention time was explored. For the series of small peptides studied, higher ESI response was observed for analytes with longer reversed-phase HPLC retention times. This correlation existed for both experimentally measured retention times and those calculated from amino acid retention coefficients. This study is useful to ESI users since it provides a way to predict and understand anomalies in ESI response with a readily accessible experimental parameter (chromatographic retention time). In addition, the ability to correlate ESI response with chromatographic partitioning lends validity to the equilibrium partitioning model, which explains differences in ESI response on the basis of partitioning between the surface and interior phases of the ESI droplet.
引用
收藏
页码:208 / 213
页数:6
相关论文
共 50 条
  • [1] A new quantitative structure-retention relationship model for predicting chromatographic retention time of oligonucleotides
    Zhao Wei
    Liang GuiZhao
    Chen YuZhen
    Yang Li
    SCIENCE CHINA-CHEMISTRY, 2011, 54 (07) : 1064 - 1071
  • [2] A new quantitative structure-retention relationship model for predicting chromatographic retention time of oligonucleotides
    ZHAO WeiLIANG GuiZhaoCHEN YuZhen YANG Li Key Laboratory of Biorheological Science and TechnologyChongqing UniversityMinistry of EducationBioengineering CollegeChongqing UniversityChongqing China Department of MathematicsHenan Institute of Science and TechnologyXinxiang China
    Science China(Chemistry), 2011, 54 (07) : 1064 - 1071+1155
  • [4] A new quantitative structure-retention relationship model for predicting chromatographic retention time of oligonucleotides
    Wei Zhao
    GuiZhao Liang
    YuZhen Chen
    Li Yang
    Science China Chemistry, 2011, 54 : 1064 - 1071
  • [5] Predicting gas chromatographic retention time of polychlorinated dibenzo-p-dioxins from molecular structure
    Delgado, EJ
    Matamala, A
    Alderete, JB
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 2002, 216 (04): : 451 - 457
  • [6] GAS CHROMATOGRAPHIC RETENTION TIME OF FORMALDEHYDE
    SCHEPARTZ, AI
    MCDOWELL, PE
    ANALYTICAL CHEMISTRY, 1960, 32 (06) : 723 - 723
  • [7] Predicting the gas chromatographic relative retention time of polybrominated diphenyl ethers by MEDV-13 descriptors
    Zhang, Ya-Hui
    Liu, Shu-Shen
    Liu, Hong-Yan
    CHROMATOGRAPHIA, 2007, 65 (5-6) : 319 - 324
  • [8] Predicting the Gas Chromatographic Relative Retention Time of Polybrominated Diphenyl Ethers by MEDV-13 Descriptors
    Ya-Hui Zhang
    Shu-Shen Liu
    Hong-Yan Liu
    Chromatographia, 2007, 65 : 319 - 324
  • [9] MINIMIZATION OF ERRORS IN MEASUREMENT OF CHROMATOGRAPHIC RETENTION TIME
    BLUMBERG, LM
    ANALYTICAL CHEMISTRY, 1984, 56 (09) : 1726 - 1729
  • [10] Mosaic increments for predicting the gas chromatographic retention data of the chlorobenzenes
    Santiuste, JM
    Harangi, J
    Takács, JM
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1002 (1-2) : 155 - 168