Electrochemiluminescence biosensor for HPV16 detection based on the adjusting of steric hindrance effect coupled with Exonuclease III amplification strategy

被引:4
|
作者
Chen, Ming [1 ]
Li, Min [2 ]
Yang, Jiao [1 ]
Luo, Fang [1 ]
Wang, Jian [1 ]
Lin, Cuiying [1 ]
Qiu, Bin [1 ]
Lin, Zhenyu [1 ]
Huang, Xiaoli [3 ]
机构
[1] Fuzhou Univ, Coll Chem, Minist Educ Key Lab Analyt Sci Food Safety & Biol, Fujian Prov Key Lab Anal & Detect Food Safety, Fuzhou 350116, Fujian, Peoples R China
[2] Fujian Med Univ, Fujian Prov Hosp, Dept Gen Med, Prov Clin Med Coll, Fuzhou 350001, Fujian, Peoples R China
[3] Fujian Med Univ, Affiliated Hosp Fujian Med Univ 1, Dept Obstet & Gynecol, Fuzhou 350001, Fujian, Peoples R China
关键词
HPV16; Au nanocages; Signal amplification; Steric hindrance; PCR;
D O I
10.1016/j.bioelechem.2022.108149
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The effect of steric hindrance of electrode surface can affect the diffusion of the Ru(bpy)32+ toward electrode and thus in turn affect the ECL performance of the system. In this study, this character had been adopted to develop a biosensor for HPV DNA detection. Exonuclease III (Exo III) signal amplification strategy had been applied to realize signal amplification. First, hairpin probes (HP) was anchored on the surface of electrode as capture probes, HP can resistant to the hydrolyzation of Exo III due to its 3 '-protruding termini. Without the target, a large amount of cDNA modified Au nanocages (AuNCs-cDNA) can hybridize with HP and connected to surface of electrode, weak ECL signals can be detected since Ru(bpy)32+ can not diffuse freely to the electrode surface because of the steric hindrance of AuNCs-cDNA. In the presence of the target, HP can hybridize with the target to form double-stranded DNA (dsDNA) with a blunt 3 ' terminus, due to the high preference of Exo III for cleaving dsDNA with a blunt 3 ' termini, HP in dsDNA was hydrolyzed, and the target which formed dsDNA was released to hybridize with another HP, inducing the Exo III assisted amplification strategy. Due to the reduction of HP on electrode surface, the amount of AuNCs-cDNA connected to the electrode surface become small, a high ECL signal can be detected. Under the optimal conditions, the ECL response of the system has a linear relationship with logarithm of target DNA concentration in the range of 10 fM to 100 pM, and a detection limit of 3.54 fM (S/ N = 3). The proposed biosensor has high sensitivity and selectivity, which had been applied to the detection of target DNA in real sample and the satisfied results had been obtained. This system also can detect different targets by changing the DNA sequence easily.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Exonuclease III-Assisted Target Recycling Amplification Coupled with Liposome-Assisted Amplification: One-Step and Dual-Amplification Strategy for Highly Sensitive Fluorescence Detection of DNA
    Zhou, Fulin
    Li, Baoxin
    ANALYTICAL CHEMISTRY, 2015, 87 (14) : 7156 - 7162
  • [42] Multiple self-cleaning paper-based electrochemical ratiometric biosensor based on the inner reference probe and exonuclease III-assisted signal amplification strategy
    Zheng, Xiaoxiao
    Li, Li
    Zhang, Lina
    Xie, Li
    Song, Xianrang
    Yu, Jinghua
    BIOSENSORS & BIOELECTRONICS, 2020, 147
  • [43] A Label-free and Highly Sensitive Fluorescence Strategy for Mercury Ion Detection Based on Exonuclease III-aided Recycling Amplification
    Baomiao Ding
    Chenguang Liu
    Qinghua Wu
    Yun Wang
    Li Li
    Hualin Yang
    Analytical Sciences, 2018, 34 : 259 - 261
  • [44] A Label-free and Highly Sensitive Fluorescence Strategy for Mercury Ion Detection Based on Exonuclease III-aided Recycling Amplification
    Ding, Baomiao
    Liu, Chenguang
    Wu, Qinghua
    Wang, Yun
    Li, Li
    Yang, Hualin
    ANALYTICAL SCIENCES, 2018, 34 (03) : 259 - 261
  • [45] A low-noise ratiometric fluorescence biosensor for detection of Pb2+ based on DNAzyme and exonuclease III-assisted cascade signal amplification
    Jin, Huali
    Liu, Ruike
    Bai, Tian
    Wei, Min
    He, Baoshan
    Suo, Zhiguang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (05) : 1899 - 1907
  • [46] Visual detection of microRNAs using gold nanorod-based lateral flow nucleic acid biosensor and exonuclease III-assisted signal amplification
    Zhang, Jing
    Yan, Chao
    Liu, Guodong
    MICROCHIMICA ACTA, 2024, 191 (08)
  • [47] A highly sensitive fluorescence biosensor for aflatoxins B1 detection based on polydiacetylene liposomes combined with exonuclease III-assisted recycling amplification
    Tao, Chunxu
    Wang, Junyan
    Zhu, Ying
    Ding, Chao
    Shen, Zhuoyue
    Sun, Danni
    Cao, Shanshan
    Jiang, Xinrong
    Li, Yaqi
    Liu, Chang
    Zhang, Qi
    Li, Shijie
    Zhang, Xinyan
    Shi, Qiaoqiao
    Kong, Dezhao
    MICROCHIMICA ACTA, 2024, 191 (07)
  • [48] An electrochemical biosensor for sensitive detection of Hg2+ based on exonuclease III-assisted target recycling and hybridization chain reaction amplification strategies
    Xiong, Erhu
    Zhang, Xiaohua
    Liu, Yunqing
    Zhou, Jiawan
    Yu, Peng
    Chen, Jinhua
    ANALYTICAL METHODS, 2016, 8 (09) : 2106 - 2111
  • [49] Controlled-Release Electrochemiluminescence Biosensor with Strong Self-On Effect by a Multiple Signal Amplification Strategy for Trace Detection of Prostate-Specific Antigen
    Huang, Ziqiu
    Zhao, Lu
    Guo, Qingfang
    Fan, Dawei
    Ren, Xiang
    Wei, Qin
    Wu, Dan
    ANALYTICAL CHEMISTRY, 2024, 96 (17) : 6659 - 6665
  • [50] Label-Free and Sensitive Electrochemical Detection of DNA Methylation Damage Based on DNA Glycosylase Recognition and Excision Coupled with Exonuclease III Amplification
    Zhang, Qing-Zheng
    Su, Chun-Bo
    Shi, San-Jun
    Gao, Yue
    Huang, Rong-Fu
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (11)