Distortion Correction Protocol for Digital Image Correlation after Scanning Electron Microscopy: Emphasis on Long Duration and Ex-Situ Experiments

被引:35
|
作者
Mello, A. W. [1 ]
Book, T. A. [1 ]
Nicolas, A. [1 ]
Otto, S. E. [1 ]
Gilpin, C. J. [2 ]
Sangid, M. D. [1 ]
机构
[1] Purdue Univ, Sch Aeronaut & Astronaut, 701 W Stadium Ave, W Lafayette, IN 47907 USA
[2] Purdue Univ, Life Sci Microscopy Facil, 170 S Univ St, W Lafayette, IN 47907 USA
基金
美国国家科学基金会;
关键词
Microstructure; Digital image correlation; Scanning electron microscopy; Electron backscatter diffraction; Strain localization; Image distortion; LARGE-DEFORMATION MEASUREMENTS; STRAIN LOCALIZATION; QUANTITATIVE SMALL; MAGNIFICATIONS; BOUNDARIES;
D O I
10.1007/s11340-017-0303-1
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Recently, scanning electron microscopy (SEM) has been used for digital image correlation (DIC), as micrographs can be acquired with high magnification, providing improved resolution to quantify strain heterogeneities. However, it has been shown by researchers that SEM images can be problematic due to inherent electromagnetic distortions that are not present in optical images. Drift, spatial distortions, and magnification uncertainties are the main issues that can seriously affect the accuracy of localized strain measurements. The present work focuses on long duration experiments, for which images are taken days or weeks apart. We have proposed a systematic procedure to reduce drift, correct spatial distortion, and account for magnification variations between pairs of acquired images. Additionally, SEM parameters are discussed and chosen to increase the signal-to-noise ratio and improve the accuracy of the DIC measurements. The spatial distortion correction increases the repeatability of the correlated values and the precision of the measurements. The implementation for this type of correction is done by applying the measured distortion gradient of a certified grid onto the DIC strain field. The magnification adjustment increases the reliability of the strain maps, ensuring the measurements are in agreement with the actual strain induced during the experiment. We have presented a systematic protocol for ex-situ DIC experiments within the SEM and some basic cross-check procedures that can be performed to evaluate the reliability of the reference grid and the precision of the final strain map.
引用
收藏
页码:1395 / 1409
页数:15
相关论文
共 22 条
  • [1] Distortion Correction Protocol for Digital Image Correlation after Scanning Electron Microscopy: Emphasis on Long Duration and Ex-Situ Experiments
    A. W. Mello
    T. A. Book
    A. Nicolas
    S. E. Otto
    C. J. Gilpin
    M. D. Sangid
    [J]. Experimental Mechanics, 2017, 57 : 1395 - 1409
  • [2] Correction of image drift and distortion in a scanning electron microscopy
    Jin, P.
    Li, X.
    [J]. JOURNAL OF MICROSCOPY, 2015, 260 (03) : 268 - 280
  • [3] Model-based Correction of Image Distortion in Scanning Electron Microscopy
    Gnieser, Dominic
    Frase, Carl Georg
    Bosse, Harald
    Tutsch, Rainer
    [J]. MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS IX, 2010, 437 : 40 - +
  • [4] Correction of scan line shift artifacts in scanning electron microscopy: An extended digital image correlation framework
    Maraghechi, Siavash
    Hoefnagels, Johan P. M.
    Peerlings, Ron H. J.
    Geers, Marc G. D.
    [J]. ULTRAMICROSCOPY, 2018, 187 : 144 - 163
  • [5] Digital image correlation under scanning electron microscopy: Methodology and validation
    Department of Mechanical Engineering, University of Michigan, 2350 Hayward St., Ann Arbor, MI 48109, United States
    不详
    [J]. Daly, S. (samdaly@umich.edu), 1743, Society for Experimental Mechanics Inc. (53):
  • [6] Digital Image Correlation under Scanning Electron Microscopy: Methodology and Validation
    A. D. Kammers
    S. Daly
    [J]. Experimental Mechanics, 2013, 53 : 1743 - 1761
  • [7] Digital Image Correlation under Scanning Electron Microscopy: Methodology and Validation
    Kammers, A. D.
    Daly, S.
    [J]. EXPERIMENTAL MECHANICS, 2013, 53 (09) : 1743 - 1761
  • [8] Correction of Scanning Electron Microscope Imaging Artifacts in a Novel Digital Image Correlation Framework
    Maraghechi, S.
    Hoefnagels, J. P. M.
    Peerlings, R. H. J.
    Rokos, O.
    Geers, M. G. D.
    [J]. EXPERIMENTAL MECHANICS, 2019, 59 (04) : 489 - 516
  • [9] Correction of Scanning Electron Microscope Imaging Artifacts in a Novel Digital Image Correlation Framework
    S. Maraghechi
    J. P. M. Hoefnagels
    R. H. J. Peerlings
    O. Rokoš
    M. G. D. Geers
    [J]. Experimental Mechanics, 2019, 59 : 489 - 516
  • [10] Small-scale patterning methods for digital image correlation under scanning electron microscopy
    Kammers, A. D.
    Daly, S.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (12)