Intraoperative Anterior Segment Optical Coherence Tomography in the Management of Cataract Surgery: State of the Art

被引:4
|
作者
Toro, Mario Damiano [1 ,2 ]
Milan, Serena [3 ]
Tognetto, Daniele [3 ]
Rejdak, Robert [2 ]
Costagliola, Ciro [4 ]
Zweifel, Sandrine Anne [5 ]
Posarelli, Chiara [6 ]
Figus, Michele [6 ]
Rejdak, Magdalena [7 ]
Avitabile, Teresio [8 ]
Carnevali, Adriano [9 ]
Giglio, Rosa [3 ]
机构
[1] Univ Naples Federico II, Dept Publ Hlth, Eye Clin, I-80131 Naples, Italy
[2] Med Univ Lublin, Chair & Dept Gen & Pediat Ophthalmol, PL-20079 Lublin, Poland
[3] Univ Trieste, Dept Med Surg & Hlth Sci, Eye Clin, I-34134 Trieste, Italy
[4] Univ Naples Federico II, Dept Neurosci & Reprod & Odontostomatol Sci, Eye Clin, I-80131 Naples, Italy
[5] Univ Zurich, Dept Ophthalmol, CH-8091 Zurich, Switzerland
[6] Univ Pisa, Dept Surg Med & Mol Pathol & Crit Care Med, I-56126 Pisa, Italy
[7] Med Univ Warsaw, Fac Med, PL-02091 Warsaw, Poland
[8] Univ Catania, Dept Ophthalmol, I-95124 Catania, Italy
[9] Magna Graecia Univ Catanzaro, Dept Ophthalmol, I-88100 Catanzaro, Italy
关键词
anterior segment OCT; intraoperative OCT; cataract surgery; surgical technique; INTRAOCULAR-LENS POSITION; PHACOEMULSIFICATION; CAPSULOTOMY; DETACHMENT; DYNAMICS;
D O I
10.3390/jcm11133867
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The introduction of non-invasive diagnostic tools in ophthalmology has significantly reshaped current clinical practice in different settings. Recently, different anterior segment (AS) intraoperative optical coherence tomography (i-OCT) systems have been employed for different interventional procedures including cataract surgery. Materials and Methods: A review on the use of AS i-OCT in the management of cataract surgery, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines (PRISMA). The level of evidence according to the Oxford Centre for Evidence-Based Medicine (OCEM) 2011 guidelines, and the quality of evidence according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system were assessed for all included articles. Results: Out of 6302 articles initially extracted, 6302 abstracts were identified for screening and 32 of these met the inclusion/exclusion criteria for full-text review; 19 articles were excluded. Conclusions: The use of AS i-OCT in cataract surgery, even if only a few studies have a high level or grade of evidence, may represent a useful tool for novel surgeons approaching phacoemulsification but also for expert ones for teaching purposes and to plan and manage complicated cases.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Intraoperative optical coherence tomography in anterior segment surgery
    Titiyal, Jeewan S.
    Kaur, Manpreet
    Nair, Sridevi
    Sharma, Namrata
    SURVEY OF OPHTHALMOLOGY, 2021, 66 (02) : 308 - 326
  • [2] Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
    Han, Sang Beom
    Liu, Yu-Chi
    Mohamed-Noriega, Karim
    Mehta, Jodhbir S.
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [3] Indications for intraoperative anterior segment optical coherence tomography in corneal surgery
    Stefan J. Lang
    Sonja Heinzelmann
    Daniel Böhringer
    Thomas Reinhard
    Philip Maier
    International Ophthalmology, 2020, 40 : 2617 - 2625
  • [4] Indications for intraoperative anterior segment optical coherence tomography in corneal surgery
    Lang, Stefan J.
    Heinzelmann, Sonja
    Boehringer, Daniel
    Reinhard, Thomas
    Maier, Philip
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (10) : 2617 - 2625
  • [5] Intraoperative optical coherence tomography in anterior segment surgeries
    Titiyal, Jeewan S.
    Kaur, Manpreet
    Falera, Ruchita
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (02) : 116 - 121
  • [6] Intraoperative Optical Coherence Tomography in Children with Anterior Segment Anomalies
    Siebelmann, Sebastian
    Hermann, Manuel
    Dietlein, Thomas
    Bachmann, Bjoern
    Steven, Philipp
    Cursiefen, Claus
    OPHTHALMOLOGY, 2015, 122 (12) : 2582 - 2584
  • [7] Value of optical coherence tomography for anterior segment surgery
    Doors, Muriel
    Berendschot, Tos T. J. M.
    de Brabander, John
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (07): : 1213 - 1229
  • [8] Retrospective analysis of the role of anterior segment optical coherence tomography and outcomes of cataract surgery in posterior polar cataract
    Dhanaseelan, Thamizhselvi
    Odayappan, Annamalai
    Vivekanandan, Vellam Ramakrishnan
    Venkatesh, Rengaraj
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (05) : 1913 - 1917
  • [9] Intraoperative 2-dimensional optical coherence tomography as a new tool for anterior segment surgery
    Geerling, G
    Müller, M
    Winter, C
    Hoerauf, H
    Oelckers, S
    Laqua, H
    Birngruber, R
    ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (02) : 253 - 257
  • [10] Evaluation of changes of anterior segment parameters in patients with pseudoexfoliation syndrome after cataract surgery using anterior segment optical coherence tomography
    Wlaz, Aleksandra
    Kustra, Agnieszka
    Aung, Tin
    Zarnowski, Tomasz
    SCIENTIFIC REPORTS, 2024, 14 (01)