Intraoperative optical coherence tomography in anterior segment surgery

被引:17
|
作者
Titiyal, Jeewan S. [1 ]
Kaur, Manpreet [1 ]
Nair, Sridevi [1 ]
Sharma, Namrata [1 ]
机构
[1] All India Inst Med Sci, Dr Rajendra Prasad Ctr Ophthalm Sci, New Delhi, India
关键词
intraoperative optical coherence tomography br; optical coherence tomography intraoperative br; microscope integrated optical coherence tomography br; AUTOMATED ENDOTHELIAL KERATOPLASTY; MICROSCOPE-INTEGRATED OCT; IMPLANTABLE COLLAMER LENS; COLLAGEN CROSS-LINKING; HEADS-UP DISPLAY; LAMELLAR KERATOPLASTY; CATARACT-SURGERY; INTERFACE FLUID; SWEPT-SOURCE; INSTRUMENT TRACKING;
D O I
10.1016/j.survophthal.2020.07.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Intraoperative optical coherence tomography (iOCT) enables real-time visualization of ocular structures during surgery and enhances our understanding of intraoperative dynamics. iOCT aids in decision-making during various anterior segment surgeries, and its efficacy and feasibility in anterior lamellar keratoplasty and endothelial keratoplasty is well established. The landmark DISCOVER study observed that iOCT altered the surgeon decision in 38% of cases undergoing lamellar keratoplasty and provided guidance regarding the need for secondary surgical intervention. iOCT also finds an application in phacoemulsification wherein it helps to assess corneal incisions, intralenticular pressure, and posterior capsule integrity during nuclear emulsification. iOCT aids in the visualization of angle structures during placement of tubes and shunts in glaucoma surgeries and allows precise creation of partial thickness scleral flaps. In addition, iOCT helps in establishing a diagnosis, as well as provide intraoperative guidance, in pediatric patients who are not cooperative for examination. The role of iOCT in refractive surgeries and ocular surface disorders is increasingly being evaluated. The limitations of present-day iOCT systems are related to instrument compatibility, automated tracking of the surgical field, and on-table volumetric analysis of the real-time images. Technological advances may facilitate complete integration of OCT in the surgical microscopes for all surgical procedures. (c) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:308 / 326
页数:19
相关论文
共 50 条
  • [1] Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
    Han, Sang Beom
    Liu, Yu-Chi
    Mohamed-Noriega, Karim
    Mehta, Jodhbir S.
    [J]. JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [2] Indications for intraoperative anterior segment optical coherence tomography in corneal surgery
    Stefan J. Lang
    Sonja Heinzelmann
    Daniel Böhringer
    Thomas Reinhard
    Philip Maier
    [J]. International Ophthalmology, 2020, 40 : 2617 - 2625
  • [3] Indications for intraoperative anterior segment optical coherence tomography in corneal surgery
    Lang, Stefan J.
    Heinzelmann, Sonja
    Boehringer, Daniel
    Reinhard, Thomas
    Maier, Philip
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (10) : 2617 - 2625
  • [4] Intraoperative optical coherence tomography in anterior segment surgeries
    Titiyal, Jeewan S.
    Kaur, Manpreet
    Falera, Ruchita
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (02) : 116 - 121
  • [5] Intraoperative Anterior Segment Optical Coherence Tomography in the Management of Cataract Surgery: State of the Art
    Toro, Mario Damiano
    Milan, Serena
    Tognetto, Daniele
    Rejdak, Robert
    Costagliola, Ciro
    Zweifel, Sandrine Anne
    Posarelli, Chiara
    Figus, Michele
    Rejdak, Magdalena
    Avitabile, Teresio
    Carnevali, Adriano
    Giglio, Rosa
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (13)
  • [6] Intraoperative Optical Coherence Tomography in Children with Anterior Segment Anomalies
    Siebelmann, Sebastian
    Hermann, Manuel
    Dietlein, Thomas
    Bachmann, Bjoern
    Steven, Philipp
    Cursiefen, Claus
    [J]. OPHTHALMOLOGY, 2015, 122 (12) : 2582 - 2584
  • [7] Value of optical coherence tomography for anterior segment surgery
    Doors, Muriel
    Berendschot, Tos T. J. M.
    de Brabander, John
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (07): : 1213 - 1229
  • [8] Intraoperative 2-dimensional optical coherence tomography as a new tool for anterior segment surgery
    Geerling, G
    Müller, M
    Winter, C
    Hoerauf, H
    Oelckers, S
    Laqua, H
    Birngruber, R
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (02) : 253 - 257
  • [9] Anterior segment optical coherence tomography
    Ang, Marcus
    Baskaran, Mani
    Werkmeister, Rene M.
    Chua, Jacqueline
    Schmidl, Doreen
    dos Santos, Valentin Aranha
    Garhoefer, Gerhard
    Mehta, Jodhbir S.
    Schmetterer, Leopold
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 2018, 66 : 132 - 156
  • [10] Optical coherence tomography of the anterior segment
    Simpson, Trefford
    Optom, Dip
    Fonn, Desmond
    Optom, Dip
    Optom, M.
    [J]. OCULAR SURFACE, 2008, 6 (03): : 117 - 127