Vertebral MRI-based radiomics model to differentiate multiple myeloma from metastases: influence of features number on logistic regression model performance

被引:19
|
作者
Liu, Jianfang [1 ]
Guo, Wei [1 ]
Zeng, Piaoe [1 ]
Geng, Yayuan [2 ]
Liu, Yan [3 ]
Ouyang, Hanqiang [4 ]
Lang, Ning [1 ]
Yuan, Huishu [1 ]
机构
[1] Peking Univ Third Hosp, Dept Radiol, 49 North Garden Rd, Beijing 100191, Peoples R China
[2] Huiying Med Technol Co Ltd, Dongsheng Sci & Technol Pk, Beijing 100192, Peoples R China
[3] Peking Univ Third Hosp, Lymphoma Res Ctr, Dept Hematol, 49 North Garden Rd, Beijing 100191, Peoples R China
[4] Peking Univ Third Hosp, Dept Orthoped, 49 North Garden Rd, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
Metastases; Multiple myeloma; Radiomics; Magnetic resonance imaging; CANCER; PRECISION; MEDICINE; EVENTS;
D O I
10.1007/s00330-021-08150-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives This study aimed to use the most frequent features to establish a vertebral MRI-based radiomics model that could differentiate multiple myeloma (MM) from metastases and compare the model performance with different features number. Methods We retrospectively analyzed conventional MRI (T1WI and fat-suppression T2WI) of 103 MM patients and 138 patients with metastases. The feature selection process included four steps. The first three steps defined as conventional feature selection (CFS), carried out 50 times (ten times with 5-fold cross-validation), included variance threshold, SelectKBest, and least absolute shrinkage and selection operator. The most frequent fixed features were selected for modeling during the last step. The number of events per independent variable (EPV) is the number of patients in a smaller subgroup divided by the number of radiomics features considered in developing the prediction model. The EPV values considered were 5, 10, 15, and 20. Therefore, we constructed four models using the top 16, 8, 6, and 4 most frequent features, respectively. The models constructed with features selected by CFS were also compared. Results The AUCs of 20EPV-Model, 15EPV-Model, and CSF-Model (AUC = 0.71, 0.81, and 0.78) were poor than 10EPV-Model (AUC = 0.84, p < 0.001). The AUC of 10EPV-Model was comparable with 5EPV-Model (AUC = 0.85, p = 0.480). Conclusions The radiomics model constructed with an appropriate small number of the most frequent features could well distinguish metastases from MM based on conventional vertebral MRI. Based on our results, we recommend following the 10 EPV as the rule of thumb for feature selection.
引用
收藏
页码:572 / 581
页数:10
相关论文
共 34 条
  • [21] An MRI-based joint model of radiomics and spatial distribution differentiates autoimmune encephalitis from low-grade diffuse astrocytoma
    Piao, Sirong
    Luo, Xiao
    Bao, Yifang
    Hu, Bin
    Liu, Xueling
    Zhu, Yuqi
    Yang, Liqin
    Geng, Daoying
    Li, Yuxin
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [22] Model incorporating multiple diffusion MRI features: development and validation of a radiomics-based model to predict adult-type diffuse gliomas grade
    Wang, Peng
    Xie, Shenghui
    Wu, Qiong
    Weng, Lixin
    Hao, Zhiyue
    Yuan, Pengxuan
    Zhang, Chi
    Gao, Weilin
    Wang, Shaoyu
    Zhang, Huapeng
    Song, Yang
    He, Jinlong
    Gao, Yang
    EUROPEAN RADIOLOGY, 2023, 33 (12) : 8809 - 8820
  • [23] Model incorporating multiple diffusion MRI features: development and validation of a radiomics-based model to predict adult-type diffuse gliomas grade
    Peng Wang
    Shenghui Xie
    Qiong Wu
    Lixin Weng
    Zhiyue Hao
    Pengxuan Yuan
    Chi Zhang
    Weilin Gao
    Shaoyu Wang
    Huapeng Zhang
    Yang Song
    Jinlong He
    Yang Gao
    European Radiology, 2023, 33 : 8809 - 8820
  • [24] Differential diagnosis of atypical and anaplastic meningiomas based on conventional MRI features and ADC histogram parameters using a logistic regression model nomogram
    Han, Tao
    Long, Changyou
    Liu, Xianwang
    Jing, Mengyuan
    Zhang, Yuting
    Deng, Liangna
    Zhang, Bin
    Zhou, Junlin
    NEUROSURGICAL REVIEW, 2023, 46 (01)
  • [25] Differential diagnosis of atypical and anaplastic meningiomas based on conventional MRI features and ADC histogram parameters using a logistic regression model nomogram
    Tao Han
    Changyou Long
    Xianwang Liu
    Mengyuan Jing
    Yuting Zhang
    Liangna Deng
    Bin Zhang
    Junlin Zhou
    Neurosurgical Review, 46
  • [26] A radiomics model from joint FDG-PET and MRI texture features for the prediction of lung metastases in soft-tissue sarcomas of the extremities
    Vallieres, M.
    Freeman, C. R.
    Skamene, S. R.
    El Naqa, I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (14): : 5471 - 5496
  • [27] Multiple Regression based Imputation for Individualizing Template Human Model from a Small Number of Measured Dimensions
    Nohara, Ryuki
    Endo, Yui
    Murai, Akihiko
    Takemura, Hiroshi
    Kouchi, Makiko
    Tada, Mitsunori
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2188 - 2193
  • [28] Diffusion-weighted imaging-based radiomics model using automatic machine learning to differentiate cerebral cystic metastases from brain abscesses
    Linyang Cui
    Zheng Qin
    Siyuan Sun
    Weihua Feng
    Mingyuan Hou
    Dexin Yu
    Journal of Cancer Research and Clinical Oncology, 150
  • [29] Research about the Influence of Incentive Method towards Executive and Corporation Performance Based on Multiple Regression Model
    Wang, Nanhao
    Tang, Yichong
    Liang, Fan
    PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON ECONOMICS, FINANCE AND STATISTICS (ICEFS 2017), 2017, 26 : 424 - 430
  • [30] Diffusion-weighted imaging-based radiomics model using automatic machine learning to differentiate cerebral cystic metastases from brain abscesses
    Cui, Linyang
    Qin, Zheng
    Sun, Siyuan
    Feng, Weihua
    Hou, Mingyuan
    Yu, Dexin
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2024, 150 (03)