A new method for ac machine turn insulation diagnostic based on high frequency resonances

被引:123
|
作者
Perisse, Frederic [1 ]
Werynski, Piotr [1 ]
Roger, Daniel [1 ]
机构
[1] Univ Artois, LSEE, F-62400 Bethune, France
关键词
ac machines; life estimation; machine windings; rotating machine insulation; power system monitoring;
D O I
10.1109/TDEI.2007.4339494
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The stator insulation breakdown is a major cause of ac machine failures. Ground insulation defaults are easily detected by classical systems based on leakage current measurements, however the turn-to-turn insulation degradations are more difficult to detect. For large machines, on-line methods, based on partial discharge detection and analysis, give good results but they cannot be used for low-voltage machines fed by adjustable speed drives (ASD). This paper presents a new monitoring system able to detect slight variations of high frequency resonances in the winding of a working machine fed by an industrial inverter. The new system works in association with statistical data on accelerated aging of the magnet wire used to build the machine.
引用
收藏
页码:1308 / 1315
页数:8
相关论文
共 50 条
  • [1] High frequency behavior of AC machine: Application of turn insulation aging diagnostic
    Perisse, Frederic
    Werynski, Piotr
    Roger, Daniel
    CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, : 555 - +
  • [2] Turn to Turn Insulation - a diagnostic tests method
    Decner, Adam
    Glinka, Tadeusz
    Polak, Artur
    Zawilak, Jan
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (12): : 35 - 37
  • [3] Diagnostic based on high frequency resonances and information fusion
    Perisse, F.
    Lefevre, E.
    Mercier, D.
    Roger, D.
    Mateo, E.
    CONFERENCE RECORD OF THE 2008 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 2008, : 628 - +
  • [4] Robust Diagnostics of Stator Insulation Based on High Frequency Resonances Measurements
    Perisse, F.
    Mercier, D.
    Lefevre, E.
    Roger, D.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (05) : 1496 - 1502
  • [5] High-sensitive state perception method for inverter-fed machine turn insulation based on FrFT-Mel
    Ruitian Fan
    Xing Lei
    Tao Jia
    Menglong Qin
    Hao Li
    Dawei Xiang
    Global Energy Interconnection, 2024, 7 (02) : 155 - 165
  • [6] High-sensitive state perception method for inverter-fed machine turn insulation based on FrFT-Mel
    Fan, Ruitian
    Lei, Xing
    Jia, Tao
    Qin, Menglong
    Li, Hao
    Xiang, Dawei
    GLOBAL ENERGY INTERCONNECTION-CHINA, 2024, 7 (02): : 155 - 165
  • [7] New Diagnostic Method of Electrical Insulation Properties based on Current Integration
    Takada, Tatsuo
    Fujitomi, Toshiyuki
    Mori, Takuma
    Iwata, Tomoyuki
    Ono, Taiki
    Miyake, Hiroaki
    Tanaka, Yasuhiro
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (04) : 2549 - 2558
  • [8] On Line Detection of Inverter Fed AC Machine Insulation Health State using High Frequency Voltage Excitation
    Wolbank, Th. M.
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 4084 - 4090
  • [9] An Insulation Test Method Based on the Dielectric Insulation Life for Windings in High-Frequency Transformer
    Zhao Y.
    Zhang G.
    Han D.
    Li K.
    Yang F.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (13): : 2932 - 2939
  • [10] An Indirect AC-AC Converter With Power Factor Correction and High Frequency Insulation
    da Silva, Emerson J. A.
    de Ameida, Bruno R.
    Praca, Paulo P.
    Oliveira, Demercil de S., Jr.
    Barreto, Luiz H. S. C.
    Marcelo Antunes, Fernando Luiz
    2018 13TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2018, : 651 - 658