A Linear Synthetic Focusing Method for Microwave Imaging of 2-D Objects

被引:0
|
作者
Gholipur, Tayebeh [1 ]
Nakhkash, Mansor [1 ]
Zoofaghari, Mohammad [1 ]
机构
[1] Yazd Univ, Dept Elect Engn, Yazd 89195741, Iran
关键词
Extended target; focusing method; incomplete multistatic response (IMSR) matrix; microwave imaging (MI); multiple signal classification (MUSIC) algorithm; INFORMATION-THEORETIC CRITERIA; MUSIC ALGORITHM; DIELECTRIC-PROPERTIES; EXTENDED TARGETS; CANCER-DETECTION; BREAST;
D O I
10.1109/TMTT.2018.2860955
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a linear synthetic focusing method (SFM) in order to mitigate the drawbacks of the classical multiple signal classification (MUSIC) algorithm for microwave imaging (MI). The determination of noise subspace dimension for MUSIC algorithm is a challenge when imaging an extended target. That is because an extended target comprises many point scatterers and a practical MI system provides an incomplete multistatic response (IMSR) matrix. The SFM obtains a focused multistatic response matrix for each location in the imaging region, which contains, mostly, the scattered field of a point scatterer at that location. In this way, the signal subspace is reduced to the one for a point scatterer, whose singular values are well-separated from those of the noise subspace. The proposed SFM is applied to the breast cancer detection using synthetic data. It is also applied to the experimental data given by Institute Fresnel to test the SFM for scenarios other than biomedical uses. It is shown that the SFM provides superior results over the classical MUSIC algorithm, especially for extended targets and IMSR matrices.
引用
收藏
页码:5042 / 5050
页数:9
相关论文
共 50 条
  • [11] Improved Focusing Method for 3-D Imaging using Row-Column-Addressed 2-D Arrays
    Bouzari, Hamed
    Engholm, Mathias
    Stuart, Matthias Bo
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [12] Spatial sampling optimization of 2-D array for medical imaging with elevation focusing
    Doisy, Y
    DebaillonVesque, C
    Gelly, JF
    ACOUSTICAL IMAGING, VOL 22, 1996, 22 : 473 - 478
  • [13] Extracting RCS of conformal antenna based on 2-D microwave imaging
    Li, N. (linanjing76@163.com), 1945, Chinese Society of Astronautics (42):
  • [14] INSPECTION OF 2-D OBJECTS USING PATTERN-MATCHING METHOD
    HAN, MH
    JANG, DS
    FOSTER, J
    PATTERN RECOGNITION, 1989, 22 (05) : 567 - 575
  • [15] Influence of 2-D Transceiver Array Aperture Size and Polarization on 3-D Microwave Imaging of Subsurface Objects Under Born Approximation
    Tao, Kemeng
    Ma, Sijia
    Han, Feng
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2025, 73 (01) : 456 - 469
  • [16] Quantification of 3-D field effects during 2-D microwave imaging
    Meaney, PM
    Paulsen, KD
    Geimer, SD
    Haider, SA
    Fanning, MW
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (07) : 708 - 720
  • [17] A Novel 2-D Synthetic Aperture Focusing Technique for Acoustic-Resolution Photoacoustic Microscopy
    Jeon, Seungwan
    Park, Jihoon
    Managuli, Ravi
    Kim, Chulhong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (01) : 250 - 260
  • [18] Synthetic Microwave Focusing Techniques for Medical Imaging: Fundamentals, Limitations, and Challenges
    Abbosh, Younis M.
    Sultan, Kamel
    Guo, Lei
    Abbosh, Amin
    BIOSENSORS-BASEL, 2024, 14 (10):
  • [19] A Simple Method for 2-D In Vivo Dosimetry by Portal Imaging
    Peca, Stefano
    Brown, Derek Wilson
    Smith, Wendy Lani
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (06) : 944 - 955
  • [20] A Galerkin Method for the Simulation of the Transient 2-D/2-D and 3-D/3-D Linear Boltzmann Equation
    Matthias K. Gobbert
    Samuel G. Webster
    Timothy S. Cale
    Journal of Scientific Computing, 2007, 30 : 237 - 273