Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups

被引:188
|
作者
Wroblewski, BM [1 ]
Siney, PD [1 ]
Dowson, D [1 ]
Collins, SN [1 ]
机构
[1] UNIV LEEDS,DEPT MECH ENGN,LEEDS LS2 9JT,W YORKSHIRE,ENGLAND
来源
关键词
D O I
10.1302/0301-620X.78B2.0780280
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We report the findings from independent prospective clinical and laboratory-based joint-simulator studies of the performance of ceramic femoral heads of 22.225 mm diameter in cross-linked polyethylene (XLP) acetabular cups. We found remarkable qualitative and quantitative agreement between the clinical and simulator results for the wear characteristics with time, and confirmed that ceramic femoral heads penetrate the XLP cups at only about half the rate of otherwise comparable metal heads. In the clinical study, 19 hips in 17 patients were followed for an average of 77 months, In the hip-joint simulator a similar prosthesis was tested for 7.3 million cycles. Both clinical and simulator results showed relatively high rates of penetration over the first 18 months or 1.5 million cycles, followed by a very much lower wear thereafter, Once an initial bedding-in of 0.2 mm to 0.4 mm had taken place the subsequent rates of penetration were very small, The initial clinical wear during bedding-in averaged 0.29 mm/year; subsequent progression was an order of magnitude lower at about 0.022 mm/year, lower than the 0.07 mm/year in metal-to-UHMWP Charnley LFAs. Our results show the excellent tribological features of alumina-ceramic-to-XLP implants, and also confirm the value of well-designed joint simulators for the evaluation of total joint replacements.
引用
收藏
页码:280 / 285
页数:6
相关论文
共 50 条
  • [21] Highly cross-linked polyethylene is the new 'gold standard' bearing material for total hip arthroplasty
    Medley, John B.
    BIOSURFACE AND BIOTRIBOLOGY, 2021, 7 (02) : 53 - 59
  • [22] Cross-Linked Polyethylene for Total Hip Arthroplasty: A Model for Evaluation of a Medical Device
    Namba, Robert S.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (15):
  • [23] SECOND-GENERATION HIGHLY CROSS-LINKED POLYETHYLENE IN TOTAL HIP ARTHROPLASTY
    Parekh, Amit
    Sood, Anshum
    Monsef, Jad Bou
    Hamouda, Mohammed
    Hussain, Awais
    Gonzalez, Mark
    JBJS REVIEWS, 2021, 9 (04)
  • [24] Early Outcomes of Sequentially Cross-Linked Thin Polyethylene Liners with Large Diameter Femoral Heads in Total Hip Arthroplasty
    Sayeed, Siraj A.
    Mont, Michael A.
    Costa, Christopher R.
    Johnson, Aaron J.
    Naziri, Qais
    Bonutti, Peter M.
    Delanois, Ronald E.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2011, 69 : S90 - S94
  • [25] Wear resistant performance of highly cross-linked and annealed ultra-high molecular weight polyethylene against ceramic heads in total hip arthroplasty
    Sato, Taishi
    Nakashima, Yasuharu
    Akiyama, Mio
    Yamamoto, Takuaki
    Mawatari, Taro
    Itokawa, Takashi
    Ohishi, Masanobu
    Motomura, Goro
    Hirata, Masanobu
    Iwamoto, Yukihide
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (12) : 2031 - 2037
  • [26] A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners
    Engh, C. Anderson, Jr.
    Stepniewski, Adam S.
    Ginn, Stuart D.
    Beykirch, Sarah E.
    Sychterz-Terefenko, Christi J.
    Hopper, Robert H., Jr.
    Engh, Charles A.
    JOURNAL OF ARTHROPLASTY, 2006, 21 (06): : 17 - 25
  • [27] Manufacturing, oxidation, mechanical properties and clinical performance of highly cross-linked polyethylene in total hip arthroplasty
    Singh, Gurpreet
    Klassen, Robert
    Howard, James
    Naudie, Douglas
    Teeter, Matthew
    Lanting, Brent
    HIP INTERNATIONAL, 2018, 28 (06) : 573 - 583
  • [28] Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty
    Jacobs, Cale A.
    Christensen, Christian P.
    Greenwald, A. Seth
    McKellop, Harry
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (12): : 2779 - 2786
  • [29] Clinical performance of highly cross-linked Polyethylenes in total hip arthroplasty
    不详
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (03): : 628 - 628
  • [30] Preliminary Clinical and Radiographic Results of Large Ceramic Heads on Highly Cross-linked Polyethylene
    Meftah, Morteza
    Ebrahimpour, Prouskeh Bruce
    He, Chuan
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    ORTHOPEDICS, 2011, 34 (06) : 421 - 421