A Novel High-Voltage Transmission Line Joint Temperature Monitoring System Using Hybrid Communication Networks

被引:7
|
作者
Jiang, Chao [1 ]
Xie, Jilong [1 ,2 ]
Zhao, Jian [1 ]
Zhang, Xihai [1 ]
机构
[1] Northeast Agr Univ, Coll Elect & Informat, Harbin 150030, Peoples R China
[2] Harbin Vocat & Tech Coll, Coll Mech & Elect Engn, Harbin 150040, Peoples R China
基金
中国国家自然科学基金;
关键词
Monitoring; Temperature measurement; Temperature sensors; Transmission line measurements; Zigbee; Sensors; Temperature distribution; LoRa; LPWAN; NB-IoT; transmission line junction temperature; ZigBee; INTERNET; THINGS;
D O I
10.1109/ACCESS.2021.3097372
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Line joint temperature monitoring is used in high-voltage transmission lines to improve the reliability and safety of power lines. However, traditional monitoring methods (e.g., manual inspection, UAV inspection, short-range wireless technology, etc.) cannot realize real-time monitoring of line joint temperature in remote areas. In this paper, we proposed a novel real-time monitoring system, which adopted a communication method combining ZigBee and LPWAN technology (LoRa and NB-IoT) for long-distance transmission. In this system, each power tower was regarded as a communication node that contained a main node and multiple subnodes. First, each node collected temperature data of the transmission line junctions by ZigBee and microprocessor processed and analyzed the data. Second, the LoRa multihop communication technology was used for transmission of the data between adjacent nodes to achieve wider coverage and a longer transmission distance. Finally, the end of the network was a main node, i.e., an LoRa-NB-IoT gateway. The temperature data of all nodes were transmitted to the "USR Cloud" by the NB-IoT technology. By conducting a system test, the system can meet the requirements of long-distance communication outside and reduce power consumption. After calculation, the system communication packet loss rate is approximately 3.3%, and the average power consumption of the system is about 21.19 mA. The PC can monitor the transmission line junction temperature in real time, transmission is stable, and the alarm function can be also realized. Therefore, the system is more suitable for temperature monitoring of line junctions in remote areas, achieving long-distance data acquisition and transmission through low power consumption and high transmission rate.
引用
收藏
页码:109478 / 109487
页数:10
相关论文
共 50 条
  • [1] High-Voltage Power Line Communication System for Hybrid Vehicle
    Takanashi, Masaki
    Harada, Tomohisa
    Takahashi, Atsuhiro
    Tanaka, Hiroya
    Hayashi, Hiroaki
    Hattori, Yoshiyuki
    [J]. 2015 INTERNATIONAL SYMPOSIUM ON POWER LINE COMMUNICATIONS AND ITS APPLICATIONS (ISPLC), 2015, : 222 - 227
  • [2] Routing Design of Mesh Communication System for High-voltage Transmission Line
    Fan, Weilin
    Yuan, Hualu
    Gao, Qiang
    Lin, Fuguo
    [J]. INTERNATIONAL CONFERENCE ON COMPUTATIONAL AND INFORMATION SCIENCES (ICCIS 2014), 2014, : 724 - 730
  • [3] Novel Application of Magnetoresistive Sensors for High-Voltage Transmission-Line Monitoring
    Sun, X.
    Lui, K. S.
    Wong, K. K. Y.
    Lee, W. K.
    Hou, Y.
    Huang, Q.
    Pong, P. W. T.
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (10) : 2608 - 2611
  • [4] High-Voltage Power Line Communication in a Hybrid Vehicle
    Takanashi, Masaki
    Takahashi, Atsuhiro
    Tanaka, Hiroya
    Hayashi, Hiroaki
    Hattori, Yoshiyuki
    [J]. IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2017, E100A (08) : 1705 - 1713
  • [5] Design of Temperature Monitoring and Data Transmission System for High-voltage Cable Connector
    Zhao, Yi-song
    Li, Tong-zhe
    Lang, Fu-cheng
    Yi, Wen-long
    [J]. PROCEEDINGS OF THE 2019 31ST CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2019), 2019, : 3499 - 3502
  • [6] Design of temperature monitoring system for high-voltage equipment based on wireless communication
    Jiang, He
    Zhang, Peiming
    Weng, Guihua
    [J]. Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2009, 30 (09): : 1969 - 1975
  • [7] HYBRID TRANSMISSION-LINE GREINACHER HIGH-VOLTAGE GENERATOR
    BRAUTTI, G
    RAINO, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 241 (2-3): : 598 - 599
  • [8] A NOVEL INSPECTION ROBOT MOVING ON HIGH-VOLTAGE POWER TRANSMISSION LINE
    Tao Guanghong
    Fang Lijin
    [J]. ASSISTIVE ROBOTICS, 2016, : 275 - 282
  • [9] Channel Measurement and Modeling of High-Voltage Power Line Communication in a Hybrid Vehicle
    Takanashi, Masaki
    Takahashi, Atsuhiro
    Tanaka, Hiroya
    Hayashi, Hiroaki
    Harada, Tomohisa
    Hattori, Yoshiyuki
    [J]. 2014 18TH IEEE INTERNATIONAL SYMPOSIUM ON POWER LINE COMMUNICATIONS AND ITS APPLICATIONS (ISPLC), 2014, : 52 - 57
  • [10] High-Voltage Transmission Line Inspection Robot
    Gulzar, Muhammad Azib
    Kumar, Kundan
    Javed, Muhammad Asad
    Sharif, Muhammad
    [J]. 2018 INTERNATIONAL CONFERENCE ON ENGINEERING & EMERGING TECHNOLOGIES (ICEET), 2018, : 17 - 23