Numerical Analysis of Post-Tensioned Coupled Wall

被引:0
|
作者
Cai, Xiaoning [1 ]
Meng, Shaoping [1 ]
Chen, Jiajia [1 ]
Sun, Weiwei [2 ]
机构
[1] Southeast Univ, Minist Educ, Nanjing 210096, Peoples R China
[2] Nanjing Univ Sci & Technol, Dept Civil Engn, Nanjing 210094, Peoples R China
来源
ADVANCES IN STRUCTURES, PTS 1-5 | 2011年 / 163-167卷
关键词
Post Tensioned; Coupled Wall; Low-Cyclic Loading Test; Elasto-Plastic Performance; Numerical Analysis; SEISMIC BEHAVIOR; CONCRETE;
D O I
10.4028/www.scientific.net/AMR.163-167.1935
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Based on OpenSEES, nonlinear beam-column element based on fiber model and considered nonlinear shear deformation was used to simulate wall limb; zero-length elements were used to simulate action of prestressing tendon and connecting reinforcement in the interface between coupling beam and wall limb; the hysteretic models of the zero-length elements were established by programming. The low-cyclic loading tests of two PCW specimens were introduced. Results of the numerical analysis and the tests indicate that elasto-plastic performances of PCW can be well simulated by numerical analysis, analysis model based on OpenSEES can be applied to non-linear analysis and of good precision; PCW is of good self-centering ability with little residual deformation after unloading, and damage concentrating in certain parts that can be repaired after earthquake; energy dissipation capacity of PCW is increased because of the connecting reinforcement.
引用
收藏
页码:1935 / 1939
页数:5
相关论文
共 50 条