Numerical Analysis of Post-Tensioned Coupled Wall

被引:0
|
作者
Cai, Xiaoning [1 ]
Meng, Shaoping [1 ]
Chen, Jiajia [1 ]
Sun, Weiwei [2 ]
机构
[1] Southeast Univ, Minist Educ, Nanjing 210096, Peoples R China
[2] Nanjing Univ Sci & Technol, Dept Civil Engn, Nanjing 210094, Peoples R China
来源
ADVANCES IN STRUCTURES, PTS 1-5 | 2011年 / 163-167卷
关键词
Post Tensioned; Coupled Wall; Low-Cyclic Loading Test; Elasto-Plastic Performance; Numerical Analysis; SEISMIC BEHAVIOR; CONCRETE;
D O I
10.4028/www.scientific.net/AMR.163-167.1935
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Based on OpenSEES, nonlinear beam-column element based on fiber model and considered nonlinear shear deformation was used to simulate wall limb; zero-length elements were used to simulate action of prestressing tendon and connecting reinforcement in the interface between coupling beam and wall limb; the hysteretic models of the zero-length elements were established by programming. The low-cyclic loading tests of two PCW specimens were introduced. Results of the numerical analysis and the tests indicate that elasto-plastic performances of PCW can be well simulated by numerical analysis, analysis model based on OpenSEES can be applied to non-linear analysis and of good precision; PCW is of good self-centering ability with little residual deformation after unloading, and damage concentrating in certain parts that can be repaired after earthquake; energy dissipation capacity of PCW is increased because of the connecting reinforcement.
引用
收藏
页码:1935 / 1939
页数:5
相关论文
共 50 条
  • [1] Numerical analysis for low-cyclic loading test of post-tensioned coupled wall based on OpenSEES
    Cai, Xiao-Ning
    Meng, Shao-Ping
    Sun, Wei-Wei
    Chen, Jia-Jia
    Sichuan Daxue Xuebao (Gongcheng Kexue Ban)/Journal of Sichuan University (Engineering Science Edition), 2010, 42 (SUPPL. 1): : 147 - 153
  • [2] Post-tensioned rocking dissipative timber wall systems: Numerical prediction
    Tomei, Valentina
    Zucconi, Maria
    Ferracuti, Barbara
    JOURNAL OF BUILDING ENGINEERING, 2023, 66
  • [3] A Fully Coupled Numerical Model for Unbonded Post-tensioned Timber Structures
    Dincer, A. Ersin
    Demir, Abdullah
    EUROPEAN JOURNAL OF WOOD AND WOOD PRODUCTS, 2024, 82 (04) : 943 - 956
  • [4] Numerical investigations on post-tensioned timber frames
    Ogrizovic, J.
    Wanninger, F.
    Frangi, A.
    INSIGHTS AND INNOVATIONS IN STRUCTURAL ENGINEERING, MECHANICS AND COMPUTATION, 2016, : 1720 - 1726
  • [5] Numerical investigation on the behaviour of Post-Tensioned Mechanically
    Javadi, Mehdi
    Hassanli, Reza
    Rahman, Md Mizanur
    Karim, Md Rajibul
    Nguyen, Hoang Bao Khoi
    COMPUTERS & STRUCTURES, 2024, 299
  • [6] Testing and Behavior of a Coupled Shear Wall Structure with Partially Post-Tensioned Coupling Beams
    Barbachyn, Steven M.
    Kurama, Yahya C.
    McGinnis, Michael J.
    Sause, Richard
    ACI STRUCTURAL JOURNAL, 2016, 113 (01) : 111 - 124
  • [7] Seismic design and response evaluation of unbonded post-tensioned hybrid coupled wall structures
    Kurama, Yahya C.
    Shen, Qiang
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2008, 37 (14): : 1677 - 1702
  • [8] Measured Behavior of a Reinforced Concrete Coupled Wall with Fully Post-Tensioned Coupling Beams
    Barbachyn, Steven M.
    Kurama, Yahya C.
    McGinnis, Michael J.
    Sause, Richard
    Structures Congress 2015, 2015, : 1361 - 1369
  • [9] Coupled Shear Wall with Fully Post-Tensioned Beams and Unbonded Reinforcing Bars at Toes
    Barbachyn, Steven M.
    Kurama, Yahya C.
    McGinnis, Michael J.
    Sause, Richard
    ACI STRUCTURAL JOURNAL, 2016, 113 (06) : 1381 - 1392
  • [10] A simplified analysis method for characterizing unbonded post-tensioned precast wall systems
    Aaleti, Sriram
    Sritharan, Sri
    ENGINEERING STRUCTURES, 2009, 31 (12) : 2966 - 2975