Split-volume treatment planning of multiple consecutive vertebral body metastases for Cyberknife image-guided robotic radiosurgery

被引:12
|
作者
Sahgal, Arjun [1 ]
Chuang, Cynthia
Larson, David
Huang, Kim
Petti, Paula
Weinstein, Phil
Ma, Lijun
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
关键词
Cyberknife; radiosurgery; spine; metastases;
D O I
10.1016/j.meddos.2007.04.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Cyberknife treatment planning of multiple consecutive vertebral body metastases; is challenging due to large target volumes adjacent to critical normal tissues. A split-volume treatment planning technique was developed to improve the treatment plan quality of such lesions. Treatment plans were generated for 1 to 5 consecutive thoracic vertebral bodies (CVBM) prescribing a total dose of 24 Gy in 3 fractions. The planning target volume (PTV) consisted of the entire vertebral body(ies). Treatment plans were generated considering both the de novo clinical scenario (no prior radiation), imposing a dose limit of 8 Gy to 1 cc of spinal cord, and the retreatment scenario (prior radiation) with a (lose limit of 3 Gy to I cc of spinal cord. The split-volume planning technique was compared with the standard full-volume technique only for targets ranging from 2 to 5 CVBM in length. The primary endpoint was to obtain best PTV coverage by the 24 Gy prescription isodose line. A total of 18 treatment plans were generated (10 standard and 8 split-volume). PTV coverage by the 24-Gy isodose line worsened consistently as the number of CVBM increased for both the do? novo and retreatment scenario. Split-volume planning was achieved by introducing a 0.5-cm gap, splitting the standard full-volume PTV into 2 equal length PTVs. In every case, split-volume planning resulted in improved PTV coverage by the 24-Gy isodose line ranging from 4% to 12% for the de novo scenario and, 8% to 17% for the retreatment scenario. We did not observe a significant trend for increased monitor units required, or higher doses to spinal cord or esophagus, with split-volume planning. Split-volume treatment planning significantly improves Cyberknife treatment plan quality for CVBM, as compared to the standard technique. This technique may be of particular importance in clinical situations where stringent spinal cord dose limits are required. (C) 2008 American Association of Medical Dosimetrists.
引用
收藏
页码:175 / 179
页数:5
相关论文
共 50 条
  • [21] Image-Guided Robotic Radiosurgery for the Treatment of Same Site Spinal Metastasis Recurrences
    Ehret, Felix
    Mose, Lucas
    Kufeld, Markus
    Fuerweger, Christoph
    Windisch, Paul
    Haidenberger, Alfred
    Schichor, Christian
    Tonn, Joerg-Christian
    Muacevic, Alexander
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [22] Image-Guided Robotic Radiosurgery for the Management of Intramedullary Spinal Cord Metastases-A Multicenter Experience
    Ehret, Felix
    Senger, Carolin
    Kufeld, Markus
    Fuerweger, Christoph
    Kord, Melina
    Haidenberger, Alfred
    Windisch, Paul
    Ruess, Daniel
    Kaul, David
    Ruge, Maximilian
    Schichor, Christian
    Tonn, Joerg-Christian
    Muacevic, Alexander
    CANCERS, 2021, 13 (02) : 1 - 10
  • [23] Safety and feasibility of image-guided robotic radiosurgery for patients with limited bone metastases of prostate cancer
    Muacevic, Alexander
    Kufeld, Markus
    Rist, Carsten
    Wowra, Berndt
    Stief, Christian
    Staehler, Michael
    UROLOGIC ONCOLOGY-SEMINARS AND ORIGINAL INVESTIGATIONS, 2013, 31 (04) : 455 - 460
  • [24] IMAGE-GUIDED ROBOTIC STEREOTACTIC BODY RADIATION THERAPY FOR 62 LIVER METASTASES
    Vautravers, C.
    Dewas, S.
    Boncceau, F.
    Adenis, A.
    Lacornerie, T.
    Lartigau, E.
    Mirabel, X.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S115 - S115
  • [25] Image-Guided Robotic Radiosurgery for the Treatment of Lung Metastases of Renal Cell Carcinoma-A Retrospective, Single Center Analysis
    Rodler, Severin
    Goetz, Melanie
    Mumm, Jan-Niclas
    Buchner, Alexander
    Graser, Annabel
    Casuscelli, Jozefina
    Stief, Christian
    Fuerweger, Christoph
    Muacevic, Alexander
    Staehler, Michael
    CANCERS, 2022, 14 (02)
  • [26] Use of an Image-Guided Robotic Radiosurgery System for the Treatment of Canine Nonlymphomatous Nasal Tumors
    Glasser, Seth A.
    Charney, Sarah
    Dervisis, Nikolaos G.
    Witten, Matthew R.
    Ettinger, Susan
    Berg, Jason
    Joseph, Richard
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2014, 50 (02) : 96 - 104
  • [27] IMAGE-GUIDED ROBOTIC RADIOSURGERY TREATMENT AS SALVAGE THERAPY FOR LOCALLY RECURRENT PROSTATE CANCER
    Beltramo, Giancarlo
    Matei, Victor
    Longo, Giovanni
    Locatelli, Maria Cristina
    Bergantin, Achille
    Martinotti, Anna Stefania
    Ria, Francesco
    Invernizzi, Marta
    Vai, Alessandro
    Bianchi, Livia Corinna
    Maggioni, Matteo
    Dormia, Guido
    ANTICANCER RESEARCH, 2015, 35 (06) : 3641 - 3642
  • [28] CLINICAL EFFECTIVENESS OF ROBOTIC IMAGE-GUIDED STEREOTACTIC RADIOSURGERY (CYBERKNIFE) IN SELECTED PRIMARY AND SECONDARY SOFT TISSUE NEOPLASMS: A SYSTEMATIC REVIEW
    Wlodarczyk, A.
    Ceglowska, U.
    Slomka, M.
    Luchowska, K.
    VALUE IN HEALTH, 2014, 17 (07) : A616 - A616
  • [29] Efficacy, safety and outcome of frameless image-guided robotic radiosurgery for brain metastases after whole brain radiotherapy
    Lohkamp, Laura-Nanna
    Vajkoczy, Peter
    Budach, Volker
    Kufeld, Markus
    JOURNAL OF NEURO-ONCOLOGY, 2018, 138 (01) : 73 - 81
  • [30] Efficacy, safety and outcome of frameless image-guided robotic radiosurgery for brain metastases after whole brain radiotherapy
    Laura-Nanna Lohkamp
    Peter Vajkoczy
    Volker Budach
    Markus Kufeld
    Journal of Neuro-Oncology, 2018, 138 : 73 - 81