Knee Muscles Composition Using Electrical Impedance Myography and Magnetic Resonance Imaging

被引:1
|
作者
Albano, Domenico [1 ]
Gitto, Salvatore [2 ]
Vitale, Jacopo [1 ]
Bernareggi, Susan [1 ]
Lamorte, Sveva [3 ]
Aliprandi, Alberto [4 ]
Sconfienza, Luca Maria [1 ,2 ]
Messina, Carmelo [1 ,2 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, I-20161 Milan, Italy
[2] Univ Milan, Dipartimento Sci Biomed Salute, I-20122 Milan, Italy
[3] Univ Parma, Scuola Specializzaz Radiodiagnost, I-43121 Parma, Italy
[4] Ist Clin Zucchi, Unita Operat Radiol, I-20052 Monza, Italy
关键词
Skulpt Chisel (TM); electrical impedance myography; magnetic resonance imaging; body composition; sarcopenia; muscle; knee; SKELETAL-MUSCLE; SARC-F; SARCOPENIA;
D O I
10.3390/diagnostics12092217
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the correlation of electrical impedance myography (EIM) measurements of knee muscles composition using Skulpt Chisel (TM) with MRI data retrieved from muscles segmentation. A total of 140 patients (71 females, 52 +/- 21 years) underwent knee MRI, EIM with Skulpt (R) , and clinical evaluation (SARC-F questionnaire). MRIs were reviewed to assess the cross-sectional area (CSA) and skeletal muscle index (SMI = CSA/height(2)) of vastus medialis, vastus lateralis, biceps, semimembranosus, and sartorius. We tested the correlations of EIM-derived parameters [body fat-percentage (BF%) and muscle quality] with total CSA, CSA of each muscle, SMI, and SARC-F scores (0-10) using Pearson correlation coefficient. We found medium negative correlation of BF% with SMI (r = -0.430, p < 0.001) and total CSA (r = -0.445, p < 0.001), particularly with biceps (r = -0.479, p < 0.001), sartorius (r = -0.440, p < 0.001), and semimembranosus (r = -0.357, p < 0.001). EIM-derived muscle quality showed small-to-medium positive correlation with MRI measurements, ranging from r = 0.234 of biceps (p = 0.006) to r = 0.302 of total CSA (p < 0.001), except for vastus lateralis (r = 0.014, p = 0.873). SARC-F scores showed small correlations with EIM and MRI data, ranging from r = -0.132 (p = 0.121) with EIM muscle quality to r = -0.288 (p = 0.001) with CSA of vastus medialis. Hence, we observed small-to-medium correlations of muscle parameters derived from Skulpt Chisel (TM) with SARC-F scores and MRI parameters. We recommend using Skulpt Chisel (TM) with caution for assessing knee skeletal muscles composition.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Comparison between magnetic resonance imaging and electrical impedance myography for evaluating lumbar skeletal muscle composition
    Domenico Albano
    Salvatore Gitto
    Jacopo Vitale
    Susan Bernareggi
    Alberto Aliprandi
    Luca Maria Sconfienza
    Carmelo Messina
    BMC Musculoskeletal Disorders, 23
  • [2] Comparison between magnetic resonance imaging and electrical impedance myography for evaluating lumbar skeletal muscle composition
    Albano, Domenico
    Gitto, Salvatore
    Vitale, Jacopo
    Bernareggi, Susan
    Aliprandi, Alberto
    Sconfienza, Luca Maria
    Messina, Carmelo
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [3] Magnetic resonance imaging correlates with electrical impedance myography in facioscapulohumeral muscular dystrophy
    Hamel, Johanna
    Lee, Phil
    Glenn, Melanie D.
    Burka, Tekalign
    Choi, In-Young
    Friedman, Seth D.
    Shaw, Dennis W. W.
    McCalley, Ayla
    Herbelin, Laura
    Dimachkie, Mazen M.
    Lemmers, Richard
    van der Maarel, Silvere M.
    Barohn, Richard J.
    Tawil, Rabi
    Statland, Jeffrey M.
    MUSCLE & NERVE, 2020, 61 (05) : 644 - 649
  • [4] ASSESSMENT OF AGED mdx MICE BY ELECTRICAL IMPEDANCE MYOGRAPHY AND MAGNETIC RESONANCE IMAGING
    Wu, Jim S.
    Li, Jia
    Greenman, Robert L.
    Bennett, David
    Geisbush, Tom
    Rutkove, Seward B.
    MUSCLE & NERVE, 2015, 52 (04) : 598 - 604
  • [5] ELECTRICAL IMPEDANCE MYOGRAPHY OF FACE AND NECK MUSCLES: ESTABLISHING NORMATIVE VALUES
    McIlduff, Courtney
    Yim, Sung
    Pacheck, Adam
    Rutkove, Seward
    MUSCLE & NERVE, 2016, 54 (03) : 531 - 531
  • [6] Electrical Impedance Myography of Face and Neck Muscles: Establishing Normative Values
    Mcllduff, Courtney
    Yim, Sung
    Pacheck, Adam
    Geisbush, Tom
    Rutkove, Seward
    NEUROLOGY, 2016, 86
  • [7] Fast imaging for magnetic resonance electrical impedance tomography
    Hamamura, Mark J.
    Muftuler, L. Tugan
    MAGNETIC RESONANCE IMAGING, 2008, 26 (06) : 739 - 745
  • [8] Coregistration of electrical impedance tomography and magnetic resonance imaging
    Halter, R. J.
    Manwaring, P.
    Hartov, A.
    Paulsen, K. D.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 416 - 419
  • [9] Electrical Conductivity Imaging Using A Hybrid Regularization Method in Magnetic Resonance Electrical Impedance Tomography
    Wang, Zewen
    Qiu, Shufang
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 205 - +
  • [10] Electrical conductivity imaging of postmortem canine brains using magnetic resonance electrical impedance tomography
    Woo, Eung Je
    Kim, Hyung Joong
    Lee, Byung Il
    Kim, Young Tae
    Lee, Soo Yeol
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4146 - 4149