Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients

被引:147
|
作者
Frasca, Denis [1 ,2 ,3 ]
Dahyot-Fizelier, Claire [1 ,2 ,3 ]
Catherine, Karen [1 ]
Levrat, Quentin [1 ]
Debaene, Bertrand [1 ,2 ,3 ]
Mimoz, Olivier [1 ,2 ,3 ]
机构
[1] Ctr Hosp Univ Poitiers, Poitiers, France
[2] INSERM, ERI 23, F-75654 Paris 13, France
[3] Univ Poitiers, UFR Med Pharm, Poitiers, France
关键词
anemia; blood transfusion; hemoglobinometry methods; intensive care; monitoring; point-of-care; BLOOD-TRANSFUSION; ANEMIA; ANALYZER; SCORE;
D O I
10.1097/CCM.0b013e3182227e2d
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine whether noninvasive hemoglobin measurement by Pulse CO-Oximetry could provide clinically acceptable absolute and trend accuracy in critically ill patients, compared to other invasive methods of hemoglobin assessment available at bedside and the gold standard, the laboratory analyzer. Design: Prospective study. Setting: Surgical intensive care unit of a university teaching hospital. Patients: Sixty-two patients continuously monitored with Pulse CO-Oximetry (Masimo Radical-7). Interventions: None. Measurements and Results: Four hundred seventy-one blood samples were analyzed by a point-of-care device (HemoCue 301), a satellite lab CO-Oximeter (Siemens RapidPoint 405), and a laboratory hematology analyzer (Sysmex XT-2000i), which was considered the reference device. Hemoglobin values reported from the invasive methods were compared to the values reported by the Pulse CO-Oximeter at the time of blood draw. When the case-to-case variation was assessed, the bias and limits of agreement were 0.0 +/- 1.0 g/dL for the Pulse CO-Oximeter, 0.3 +/- 1.3g/dL for the point-of-care device, and 0.9 +/- 0.6 g/dL for the satellite lab CO-Oximeter compared to the reference method. Pulse CO-Oximetry showed similar trend accuracy as satellite lab CO-Oximetry, whereas the point-of-care device did not appear to follow the trend of the laboratory analyzer as well as the other test devices. Conclusion: When compared to laboratory reference values, hemoglobin measurement with Pulse CO-Oximetry has absolute accuracy and trending accuracy similar to widely used, invasive methods of hemoglobin measurement at bedside. Hemoglobin measurement with pulse CO-Oximetry has the additional advantages of providing continuous measurements, noninvasively, which may facilitate hemoglobin monitoring in the intensive care unit. (Crit Care Med 2011; 39:2277-2282)
引用
收藏
页码:2277 / 2282
页数:6
相关论文
共 50 条
  • [1] A noninvasive hemoglobin monitor in the pediatric intensive care unit
    Phillips, Michael R.
    Khoury, Amal L.
    Bortsov, Andrey V.
    Marzinsky, Amy
    Short, Kathy A.
    Cairns, Bruce A.
    Charles, Anthony G.
    Joyner, Benny L., Jr.
    McLean, Sean E.
    JOURNAL OF SURGICAL RESEARCH, 2015, 195 (01) : 257 - 262
  • [2] Noninvasive and Continuous Hemoglobin Monitoring in an Intensive Care Unit Patient with Low Hemoglobin
    Juhl, A.
    Naqvi, S.
    Aregbeyen, O.
    Shander, A.
    TRANSFUSION, 2010, 50 (11) : 2518 - 2518
  • [3] Accuracy of a subcutaneous continuous glucose monitor compared with an intravenous continuous glucose monitor in an intensive care unit
    Y Takahashi
    T Yatabe
    M Munekage
    M Sakaguchi
    A Nishigaki
    M Yokoyama
    K Hanazaki
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [4] Accuracy of a Continuous Glucose Monitor in the Intensive Care Unit: A Proposed Accuracy Standard and Calibration Protocol for Inpatient Use
    Bann, Sewon A.
    Hercus, Jess C.
    Atkins, Paul
    Alkhairy, Areej
    Loyal, Jackson P.
    Sekhon, Mypinder
    Thompson, David J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (11) : 797 - 805
  • [5] ACCURACY OF NON-INVASIVE HEMOGLOBIN MONITORING IN INTENSIVE CARE UNIT PATIENTS WITH VERY LOW HEMOGLOBIN
    Juhl, Anna
    Naqvi, Sajjad
    Aregbeyen, Oshuare
    Demir, Selma
    Shander, Aryeh
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U61 - U61
  • [6] The Accuracy of Continuous Glucose Monitoring in the Medical Intensive Care Unit
    Tingsarat, Wannita
    Buranasupkajorn, Patinut
    Khovidhunkit, Weerapan
    Boonchaya-anant, Patchaya
    Laichuthai, Nitchakarn
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (06): : 1550 - 1554
  • [7] Accuracy of continuous jugular bulb oximetry in the intensive care unit
    Coplin, WM
    O'Keefe, GE
    Grady, MS
    Grant, GA
    March, KS
    Winn, HR
    Lam, AM
    NEUROSURGERY, 1998, 42 (03) : 533 - 539
  • [8] Accuracy of continuous glucose monitoring systems in intensive care unit patients: a scoping review
    Nielsen, Christian G.
    Grigonyte-Daraskeviciene, Milda
    Olsen, Mikkel T.
    Moller, Morten H.
    Norgaard, Kirsten
    Perner, Anders
    Martensson, Johan
    Pedersen-Bjergaard, Ulrik
    Kristensen, Peter L.
    Bestle, Morten H.
    INTENSIVE CARE MEDICINE, 2024, 50 (12) : 2005 - 2018
  • [9] Noninvasive Monitoring in the Intensive Care Unit
    De Backer, Daniel
    Vincent, Jean-Louis
    SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 42 (01) : 40 - 46
  • [10] Symptoms in Patients Receiving Noninvasive Ventilation in the Intensive Care Unit
    Peterson, Pamela E.
    Tracy, Mary Fran
    Mandrekar, Jay
    Chlan, Linda L.
    NURSING RESEARCH, 2023, 72 (06) : 456 - 461