A polymeric junction membrane for solid-state reference electrodes

被引:37
|
作者
Ha, J
Martin, SM
Jeon, Y
Yoon, IJ
Brown, RB
Nam, H
Cha, GS
机构
[1] Kwangwoon Univ, Dept Chem, Chem Sensor Res Grp, Seoul 139701, South Korea
[2] Univ Michigan, Ctr Wireless Integrated MicroSyst, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Ann Arbor, MI 48109 USA
[4] Univ Utah, Sch Elect Engn & Comp Sci, Salt Lake City, UT 84112 USA
基金
美国国家科学基金会;
关键词
ion-selective electrode; reference electrode; liquid junction; cellulose acetate; polyurethane;
D O I
10.1016/j.aca.2005.06.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polymer membrane system composed of 30 wt.% cellulose acetate (CA) and polyurethane (PU) has been developed for the fabrication of mass producible solid-state reference electrodes. The CA/PU membrane exhibits appropriate adhesion to common substrates (e.g., ceramic and silicon chips) of miniaturized electrochemical sensors, allows quick hydration of internal hydrogel layer Q M KCl with a 6 wt.% water soluble polymer) deposited on micro-patterned electrodes resulting in fast preconditioning time (similar to 100 s), and provides a stable reference potential for an extended period (use-lifetime: 25-90 min) by limiting the diffusion of internal electrolytes. The potentiometric responses of the CA/PU membrane-based solid-state reference electrodes drifted rapidly (40-9OmV/h) after their use-lifetime; the results suggest that the internal electrolyte slowly fills the micro-channels of the outer membrane while maintaining stable potential, and begins to diffuse away at an increased rate from the membrane/aqueous solution interface. The potentiometric responses of the polymer membrane-based ion-selective electrodes (for Na+, K+ , Ca2+, Cl- and H+) formed on the same chip with the CA/PU membrane-coated Ag/AgCl reference electrode were examined both in aqueous and physiological samples; their analytical performance closely matched that of sensors measured against a conventional reference electrode. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 50 条
  • [1] Carbon-Nanofiber-Based Nanocomposite Membrane as a Highly Stable Solid-State Junction for Reference Electrodes
    O'Neil, Glen D.
    Buiculescu, Raluca
    Kounaves, Samuel P.
    Chaniotakis, Nikos A.
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (14) : 5749 - 5753
  • [2] PRACTICAL LIMITS FOR SOLID-STATE REFERENCE ELECTRODES
    COLLINS, SD
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1993, 10 (03) : 169 - 178
  • [3] Solid-state reference electrodes for potentiometric sensors
    U. Guth
    F. Gerlach
    M. Decker
    W. Oelßner
    W. Vonau
    [J]. Journal of Solid State Electrochemistry, 2009, 13 : 27 - 39
  • [4] Solid-state reference electrodes for potentiometric sensors
    Guth, U.
    Gerlach, F.
    Decker, M.
    Oelssner, W.
    Vonau, W.
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2009, 13 (01) : 27 - 39
  • [5] EVALUATION OF A NEW SOLID-STATE REFERENCE ELECTRODE JUNCTION MATERIAL FOR ION-SELECTIVE ELECTRODES
    DIAMOND, D
    MCENROE, E
    MCCARRICK, M
    LEWENSTAM, A
    [J]. ELECTROANALYSIS, 1994, 6 (11-12) : 962 - 971
  • [6] SOLID-STATE ELECTRODES BASED ON A MEMBRANE WITH MIXED RESPONSES
    CHERNOVA, RK
    KULAPIN, AI
    YUROVA, LA
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 50 (08) : 785 - 788
  • [7] INVESTIGATION OF SOLID SODIUM REFERENCE ELECTRODES FOR SOLID-STATE ELECTROCHEMICAL GAS SENSORS
    SCHETTLER, H
    LIU, J
    WEPPNER, W
    HUGGINS, RA
    [J]. APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1993, 57 (01): : 31 - 35
  • [8] Miniaturization of Reference Electrodes for Solid-State Lithium-Ion Batteries
    Hertle, Jonas
    Walther, Felix
    Mogwitz, Boris
    Schroeder, Steffen
    Wu, Xiaohan
    Richter, Felix H.
    Janek, Juergen
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (04)
  • [9] Reference electrodes for thin-film solid-state ionic devices
    Rutman, Jeremy
    Riess, Ilan
    [J]. SOLID STATE IONICS, 2008, 179 (1-6) : 108 - 112
  • [10] THICK-FILM REFERENCE ELECTRODES FOR SOLID-STATE PH MEASUREMENT
    BREHIER, PC
    BELFORD, RE
    [J]. ANALYTICAL PROCEEDINGS, 1995, 32 (08): : 323 - 326