A tentative method to evaluate the building material contribution to indoor gamma dose rate

被引:1
|
作者
Nuccetelli, C [1 ]
Bolzan, C [1 ]
Bochicchio, F [1 ]
机构
[1] Ist Super Sanita, Phys Lab, I-00161 Rome, Italy
来源
关键词
D O I
10.1016/S1569-4860(04)07138-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Building materials are an important source of indoor gamma dose rate, particularly in multistorey buildings. In many cases in which it is difficult to enter the dwellings to measure the indoor gamma dose rate, such as for epidemiological studies and surveys, it is actually interesting to estimate the indoor gamma dose rate. In this paper a new method to estimate the indoor gamma dose rate attributable to the building materials is presented, based on the outdoor measurements performed close to an external wall of a dwelling and a room model elaboration. The method was compared using data collected within the framework of the Italian Epidemiological study SETIL on the aetiology of childhood leukaemia, lymphoma and neuroblastoma.
引用
收藏
页码:1123 / 1127
页数:5
相关论文
共 50 条
  • [41] A new method for gamma dose-rate estimation of heterogeneous media in TL dating
    Guibert, P
    Bechtel, F
    Schvoerer, M
    Muller, P
    Balescu, S
    RADIATION MEASUREMENTS, 1998, 29 (05) : 561 - 572
  • [42] INFLUENCE OF REFILL SOIL AND BUILDING MATERIAL EQUIVALENT DOSE RATE ON NEW NUCLEAR POWER PLANT SITES
    Cidzikiene, Vigilija
    Girgzdiene, Rasele
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2014, 13 (02): : 259 - 264
  • [43] Analysis of internal gamma-ray dose to the public from brick as building material in Tamil Nadu, India
    Karthikayini, Seenuvasan
    Chandrasekaran, Ananthanarayanan
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (03) : 240 - 250
  • [44] Radiation dose contribution from coal-slag from the Ajka region used as structural building material.
    Somlai, J
    Kanyar, B
    Lendvai, Z
    Nemeth, C
    Bodnar, R
    MAGYAR KEMIAI FOLYOIRAT, 1997, 103 (10): : 515 - 518
  • [45] NEW METHOD OF GAMMA-DOSE-RATE MEASUREMENT USING ENERGY-SENSITIVE COUNTERS
    KOPP, MK
    VALENTINE, KH
    WILLIAMS, JA
    BAMBERGER, RH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) : 616 - 618
  • [46] Evaluation of gamma dose rate for the ionization chamber tube in a reactor using the Monte Carlo method
    Meng, Qing-Yu
    Feng, Run -Song
    RADIATION PHYSICS AND CHEMISTRY, 2024, 222
  • [47] Assessment of indoor radon concentration and time-series analysis of gamma dose rate in three thermal spas from Portugal
    Ana Sofia Silva
    Maria de Lurdes Dinis
    Environmental Monitoring and Assessment, 2022, 194
  • [48] Assessment of indoor radon concentration and time-series analysis of gamma dose rate in three thermal spas from Portugal
    Silva, Ana Sofia
    Dinis, Maria de Lurdes
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2022, 194 (09)
  • [49] Sequential multi-nuclide emission rate estimation method based on gamma dose rate measurement for nuclear emergency management
    Zhang, Xiaole
    Raskob, Wolfgang
    Landman, Claudia
    Trybushnyi, Dmytro
    Li, Yu
    JOURNAL OF HAZARDOUS MATERIALS, 2017, 325 : 288 - 300
  • [50] A 3-D Lagrangian (Monte carlo) method for direct plume gamma dose rate calculations
    Raza, SS
    Avila, R
    Cervantes, J
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2001, 38 (04) : 254 - 260