Use of bioelectrical impedance analysis measurements as predictors of physical performance

被引:0
|
作者
Hodgdon, JA [1 ]
Friedl, KE [1 ]
Beckett, MB [1 ]
Westphal, KA [1 ]
Shippee, RL [1 ]
机构
[1] USA, ENVIRONM MED RES INST, OCCUPAT HLTH & PERFORMANCE DIRECTORATE, NATICK, MA 01760 USA
来源
关键词
strength testing; bioelectrical impedance analysis; body composition; skinfold thickness; fat-free mass; military personnel; physical classification and selection tests;
D O I
暂无
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Through its association with fat-free mass (FFM), bioelectrical impedance analysis (BIA) offers an alternative to physical performance testing. We examined the relations between stature(2)/resistance (S-2/R), FFM, and muscular strength in data from three studies of young military men and women. Resistance was measured at 50 kHz by using the conventional tetrapolar electrode method. FFM was based on skinfold thicknesses, and estimated with the regression equations of Durnin and Womersley. Strength was measured as a one-repetition maximum on an incremental lift test (IL1RM), which is widely used by the military services to predict overall body strength. Although there was an association between IL1RM and S-2/R in each of these studies (correlations ranged from 0.35 to 0.53), correlations were strongest between FFM and S-2/R (R = 0.53 to 0.85), indicating that BIA and FFM derived from skinfold thicknesses are better correlated with each other than are the relations of either of these with physical performance. Modest increases in FFM and strength in one 8-wk training study correlated with S-2/R; however, large decreases in FFM and strength in another study (with weight losses of 10 kg in 8 wk) were not reflected by changes in S-2/R. Thus, BIA is not particularly useful for performance prediction despite its moderate relation to FFM. BIA is especially problematic with large changes in body composition, for which there are apparent deviations in hydration status; expedient methods such as skinfold predictions will be more resistant to such effects.
引用
收藏
页码:463 / 468
页数:6
相关论文
共 50 条
  • [41] The effects of acute strength training on bioelectrical impedance measurements
    Isin, Ali
    Melekoglu, Tuba
    CUKUROVA MEDICAL JOURNAL, 2019, 44 (01): : 80 - 86
  • [42] Pelvic bioelectrical impedance measurements to detect rectal filling
    Ratani, RS
    Yazaki, E
    Maw, A
    Pilot, MA
    Rogers, J
    Williams, NS
    PHYSIOLOGICAL MEASUREMENT, 1998, 19 (04) : 527 - 534
  • [43] USE OF BIOELECTRICAL IMPEDANCE IN CENTENARIANS: A SYSTEMATIC REVIEW
    Mandala, C.
    Dominguez, L. J.
    Candore, G.
    Accardi, G.
    Smith, L.
    Armata, M.
    La Carrubba, A.
    Herrero, M. T.
    Barbagallo, M.
    Veronese, N.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2022, 34 (SUPPL 1) : S199 - S199
  • [44] Bioelectrical impedance analysis at the characteristic frequency
    Ward, Leigh C.
    Cornish, Bruce H.
    NUTRITION, 2007, 23 (01) : 96 - 96
  • [45] Segmental bioelectrical impedance analysis: an update
    Ward, Leigh C.
    CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2012, 15 (05): : 424 - 429
  • [46] Bioelectrical impedance analysis in nutritional research
    Han, TS
    Lean, MEJ
    NUTRITION, 1998, 14 (09) : 707 - 708
  • [47] Bioelectrical impedance analysis in dialysis patients
    Pupim, LB
    Kent, P
    Ikizler, TA
    MINERAL AND ELECTROLYTE METABOLISM, 1999, 25 (4-6) : 400 - 406
  • [48] Bioelectrical impedance analysis principles and methods
    Kyle, UG
    Bosaeus, I
    De Lorenzo, AD
    Deurenberg, P
    Elia, M
    Gómez, JM
    Heitmann, BL
    Kent-Smith, L
    Melchior, JC
    Pirlich, M
    Scharfetter, H
    Schols, AMWJ
    Pichard, C
    CLINICAL NUTRITION, 2004, 23 (05) : 1226 - 1243
  • [49] Bioelectrical Impedance Analysis - a Comparison Method
    Sekli, Elisabeth
    Kruschitz, Renate
    Luger, Maria
    Langer, Felix
    Prager, Gerhard
    Kefurt, Ronald
    Krebs, Michael
    Ludvik, Bernhard
    Schindler, Karin
    WIENER KLINISCHE WOCHENSCHRIFT, 2015, 127 (17-18) : 746 - 747
  • [50] Bioelectrical impedance analysis in ICU patients
    L Steinhilp
    F Bubser
    S Wiesener
    C Spies
    M Boschmann
    T Schütz
    S Weber-Carstens
    Critical Care, 13 (Suppl 1):