Validation of a radiographic scoring system for haemochromatosis arthropathy

被引:21
|
作者
Dallos, Tomas [1 ,2 ]
Sahinbegovic, Enijad [2 ]
Aigner, Elmar [3 ]
Axmann, Roland [2 ]
Schoeniger-Hekele, Maximilian [4 ]
Karonitsch, Thomas [5 ]
Stamm, Tanja [5 ]
Farkas, Martin [6 ]
Karger, Thomas
Cavallaro, Alexander [7 ]
Stoelzel, Ulrich [8 ]
Keysser, Gernot [9 ]
Datz, Christian [3 ]
Schett, Georg [2 ]
Manger, Bernhard [2 ]
Zwerina, Jochen [2 ]
机构
[1] Comenius Univ, Dept Paediat 2, Bratislava 83340, Slovakia
[2] Univ Erlangen Nurnberg, Dept Internal Med 3, Erlangen, Germany
[3] Hosp Oberndorf, Dept Internal Med, Oberndorf, Austria
[4] Med Univ Vienna, Dept Internal Med 3, Div Gastroenterol, Vienna, Austria
[5] Med Univ Vienna, Dept Internal Med 3, Div Rheumatol, Vienna, Austria
[6] Hosp Wiener Neustadt, Dept Internal Med, Wiener Neustadt, Austria
[7] Univ Erlangen Nurnberg, Dept Radiol, Erlangen, Germany
[8] Chemnitz Hop, Dept Internal Med 2, Chemnitz, Germany
[9] Univ Halle Wittenberg, Dept Internal Med 1, Halle, Germany
关键词
LONG-TERM SURVIVAL; HAND OSTEOARTHRITIS; DISEASE; EPIDEMIOLOGY; ARTHRITIS;
D O I
10.1136/ard.2009.122119
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Arthropathy is one of the earliest and most common manifestations of hereditary haemochromatosis with a significant impact on quality of life. Although its radiographic features are well known, there is no assessment tool for their evaluation. Objective To develop and validate a novel scoring system for the evaluation of radiographic features of haemochromatosis arthropathy. Methods A dichotomous scoring system assessing four radiographic features of haemochromatosis arthropathy and a 4-grade scale reflecting severity of radiographic change have been developed. Standard radiographs (hand, wrist, knee and ankle) of 170 subjects (116 male, 54 female) with genetically confirmed haemochromatosis and laboratory signs of iron overload were assessed by three readers and construct validity, feasibility and cross-sectional reliability (intrareader and inter-reader) were assessed. Results Intrareader and inter-reader reliability as assessed by percentage pairwise agreement and Cohen's weighed. were good to excellent for most features and locations evaluated. Radiographic scores correlated well with clinical parameters (bony swollen joint count, hand function and physician's global health assessment; Pearson's correlation, r(2) = 0.18-0.62, p<0.0001). A complete set of radiographs took 3.4 +/- 1.2 (mean +/- SD) min to be assessed. An atlas of characteristic radiographic features was compiled. Conclusion A feasible and reliable radiological assessment tool for the evaluation of haemochromatosis arthropathy has been validated and an atlas of characteristic radiographic features provided.
引用
收藏
页码:2145 / 2151
页数:7
相关论文
共 50 条
  • [31] A radiographic scoring system to assess healing in congenital pseudarthrosis of the tibia
    Richards, B. Stephens
    Wilkes, David
    Dempsey, Molly
    Nurenberg, Pamela
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2015, 24 (02): : 118 - 122
  • [32] Development of a radiographic scoring system for new bone formation in gout
    Chang-Nam Son
    Ken Cai
    Sarah Stewart
    John Ferrier
    Karen Billington
    Yun-Jung Jack Tsai
    Thomas Bardin
    Anne Horne
    Lisa K. Stamp
    Anthony Doyle
    Nicola Dalbeth
    Arthritis Research & Therapy, 23
  • [33] ARTHROPATHY OF HAEMOCHROMATOSIS - CLINICAL AND RADIOLOGICAL ANALYSIS OF 63 PATIENTS WITH IRON OVERLOAD
    DYMOCK, IW
    HAMILTON, EB
    LAWS, JW
    WILLIAMS, R
    ANNALS OF THE RHEUMATIC DISEASES, 1970, 29 (05) : 469 - &
  • [34] Comment on: Hereditary haemochromatosis arthropathy and Doppler ultrasound findings of synovitis: reply
    Oke, Anuoluwapo R.
    Wong, Ernest
    Young-Min, Steven
    RHEUMATOLOGY, 2018, 57 (04) : 766 - 767
  • [35] VCAM-1 serum levels are associated with arthropathy in hereditary haemochromatosis
    Nell-Duxneuner, Valerie
    Axmann, Roland
    Husar-Memmer, Emma
    Dallos, Tomas
    Datz, Christian
    Stadlmayr, Andreas
    Aigner, Elmar
    Englbrecht, Matthias
    Schett, Georg
    Zwerina, Jochen
    ANNALS OF THE RHEUMATIC DISEASES, 2013, 72 (12) : 2006 - 2010
  • [36] Validation of a Congestive Hepatic Fibrosis Scoring System
    Bosch, Dustin
    Swanson, Paul E.
    Hoch, Benjamin
    Jalikis, Florencia
    Koch, Lisa
    Truong, Camtu
    Richards, Elizabeth
    Koro, Konstantin
    Yeh, Matthew M.
    MODERN PATHOLOGY, 2018, 31 : 625 - 626
  • [37] VALIDATION OF A SCORING SYSTEM FOR THE DIAGNOSIS OF AUTOIMMUNE HEPATITIS
    CZAJA, AJ
    CARPENTER, HA
    GASTROENTEROLOGY, 1995, 108 (04) : A1056 - A1056
  • [38] Validation of a Congestive Hepatic Fibrosis Scoring System
    Bosch, Dustin
    Swanson, Paul E.
    Hoch, Benjamin
    Jalikis, Florencia
    Koch, Lisa
    Truong, Camtu
    Richards, Elizabeth
    Koro, Konstantin
    Yeh, Matthew M.
    LABORATORY INVESTIGATION, 2018, 98 : 625 - 626
  • [39] A Validation of a Bender-Gestalt Scoring System
    Lonstein, Murray
    JOURNAL OF CONSULTING PSYCHOLOGY, 1954, 18 (05): : 377 - 379
  • [40] VALIDATION OF A MYASTHENIA-GRAVIS SCORING SYSTEM
    LINDBERG, C
    ANDERSEN, O
    ACTA NEUROLOGICA SCANDINAVICA, 1988, 77 : 124 - 124