Determination of X-ray detection limit and applications in perovskite X-ray detectors

被引:88
|
作者
Pan, Lei [1 ]
Shrestha, Shreetu [2 ]
Taylor, Neil [1 ]
Nie, Wanyi [2 ]
Cao, Lei R. [1 ]
机构
[1] Ohio State Univ, Nucl Engn Program, Dept Mech & Aerosp Engn, Columbus, OH 43210 USA
[2] Los Alamos Natl Lab, Ctr Integrated Nanotechnol, Mat Phys & Applicat Div, Los Alamos, NM USA
关键词
SINGLE-CRYSTALS; SENSITIVITY; PHOTOCONDUCTORS;
D O I
10.1038/s41467-021-25648-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
X-ray detection limit and sensitivity are important figure of merits for perovskite X-ray detectors, but literatures lack a valid mathematic expression for determining the lower limit of detection for a perovskite X-ray detector. In this work, we present a thorough analysis and new method for X-ray detection limit determination based on a statistical model that correlates the dark current and the X-ray induced photocurrent with the detection limit. The detection limit can be calculated through the measurement of dark current and sensitivity with an easy-to-follow practice. Alternatively, the detection limit may also be obtained by the measurement of dark current and photocurrent when repeatedly lowering the X-ray dose rate. While the material quality is critical, we show that the device architecture and working mode also have a significant influence on the sensitivity and the detection limit. Our work establishes a fair comparison metrics for material and detector development. The limit of X-ray detection is an important figure of merit for X-ray detectors, yet the suitability of method adopted from Currie's 1968 paper and the following international standard is in doubt. Here, the authors propose a statistical model that correlates dark current and photo-current, show how it can be used to determine detection limit.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Determination of quantum efficiency of X-ray detectors
    Zelikman M.I.
    [J]. Biomedical Engineering, 2001, 35 (4) : 180 - 185
  • [22] Simulation and design of folded perovskite x-ray detectors
    Henning Mescher
    Elias Hamann
    Uli Lemmer
    [J]. Scientific Reports, 9
  • [23] Simulation and design of folded perovskite x-ray detectors
    Mescher, Henning
    Hamann, Elias
    Lemmer, Uli
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [24] X-ray Detectors Based on Halide Perovskite Materials
    Tan, Yimei
    Mu, Ge
    Chen, Menglu
    Tang, Xin
    [J]. COATINGS, 2023, 13 (01)
  • [25] Comparison of mercuric iodide and lead iodide X-ray detectors for X-ray imaging applications
    Zentai, G
    Partain, L
    Pavlyuchkova, R
    Proano, C
    Schieber, M
    Shah, K
    Bennett, P
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2278 - 2282
  • [26] Comparison of mercuric iodide and lead iodide x-ray detectors for x-ray imaging applications
    Zentai, G.
    Partain, L.
    Pavlyuchkova, R.
    Proano, C.
    Schieber, A.
    Shah, K.
    Bennett, P.
    Melekhov, L.
    Gilboa, H.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2506 - 2512
  • [27] A Monte Carlo study of x-ray fluorescence in x-ray detectors
    Boone, JM
    Seibert, JA
    Sabol, JM
    Tecotzky, M
    [J]. MEDICAL PHYSICS, 1999, 26 (06) : 905 - 916
  • [28] X-ray Peltier cooled detectors for X-ray fluorescence analysis
    Loupilov, A
    Sokolov, A
    Gostilo, V
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 463 - 464
  • [29] Dependence of x-ray sensitivity of direct conversion x-ray detectors on x-ray exposure and exposure history
    Kabir, MZ
    Yunus, M
    Kasap, SO
    [J]. MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 170 - 176
  • [30] Possible applications of X-ray lasers in biology: X-ray microscopy and X-ray lasers
    Shinohara, K
    [J]. X-RAY LASERS 1996, 1996, (151): : 533 - 538