Fiber-Based Liquid-Phase Micro-Extraction of Mebeverine Enantiomers Followed by Chiral High-Performance Liquid Chromatography Analysis and Its Application to Pharmacokinetics Study in Rat Plasma

被引:3
|
作者
Hatami, Mehdi [1 ]
Farhadi, Khalil [1 ]
Tukmechi, Amir [2 ]
机构
[1] Urmia Univ, Fac Sci, Dept Chem, Orumiyeh, Iran
[2] Urmia Univ, Artemia & Aquat Anim Res Inst, Dept Pathobiol & Qual Control, Orumiyeh, Iran
关键词
mebeverine enantiomers; pharmacokinetics; chiral HPLC; rat plasma; SPECTROPHOTOMETRIC DETERMINATION; CAPILLARY-ELECTROPHORESIS; SAMPLE PREPARATION; BIOLOGICAL-FLUIDS; DOSAGE FORMS; HYDROCHLORIDE; TABLETS; HPLC; MICROEXTRACTION; METABOLISM;
D O I
10.1002/chir.22057
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The applicability of two-phase liquid-phase micro-extraction (LPME) in porous hollow polypropylene fiber for the sample preparation and the stereoselective pharmacokinetics of mebeverine (MEB) enantiomers (an antispasmodic drug) in rat after intramuscular administration were studied. Plasma was assayed for MEB enantiomer concentrations using stereospecific high-performance liquid chromatography with ultraviolet detection after a simple, inexpensive, and efficient preconcentration and clean-up hollow fiber-based LPME. Under optimized micro-extraction conditions, MEB enantiomers were extracted with 25?mu l of 1-octanol within a lumen of a hollow fiber from 0.5?ml of plasma previously diluted with 4.5?ml alkalized water (pH 10). The chromatographic analysis was carried out through chiral liquid chromatography using a DELTA S column and hexaneisopropyl alcohol (85:15?v/v) containing 0.2% triethylamine as mobile phase. The mean recoveries of (+)-MEB and (-)-MEB were 75.5% and 71.0%, respectively. The limit of detection (LOD) was 3.0?ng/ml with linear response over the concentration range of 102500?ng/ml with correlation coefficient higher than 0.993 for both enantiomers. The pharmacokinetic studies showed that the mean plasma levels of (+)-MEB were higher than those of (-)-MEB at almost all time points. Also, (+)-MEB exhibited greater tmax (peak time in concentrationtime profile), Cmax (peak concentration in concentrationtime profile), t1/2 (elimination half-life), and AUC0240?min (area under the curve for concentration versus time) and smaller CL (clearance) and Vd (apparent distribution volume) than its antipode. The obtained results implied that the absorption, distribution, and elimination of (-)-MEB were more rapid than those of (+)-MEB and there were stereoselective differences in pharmacokinetics. Chirality 24:634639, 2012. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:634 / 639
页数:6
相关论文
共 50 条
  • [21] Hollow fiber-based liquid-phase microextraction (HF-LPME) of isradipine and its main metabolite followed by chiral HPLC analysis: application to an in vitro biotransformation study
    Rodrigo Almeida Simões
    Anderson Rodrigo Moraes de Oliveira
    Pierina Sueli Bonato
    Analytical and Bioanalytical Chemistry, 2011, 399 : 2435 - 2443
  • [22] Liquid-phase microextraction combined with high-performance liquid chromatography for the enantioselective analysis of mefloquine in plasma samples
    dos Santos Magalhaes, Igor Rafael
    Bonato, Pierina Sueli
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (05) : 929 - 936
  • [23] Determination of ketamine and norketamine enantiomers in plasma by solid-phase extraction and high-performance liquid chromatography
    Svensson, JO
    Gustafsson, LL
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 678 (02): : 373 - 376
  • [24] SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE ANALYSIS OF MILRINONE IN RAT PLASMA
    DESJARDINS, S
    CAUCHY, MJ
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (04): : 943 - 952
  • [25] Hollow fiber-based liquid phase microextraction combined with high-performance liquid chromatography for extraction and determination of some antidepressant drugs in biological fluids
    Esrafili, Ali
    Yamini, Yadollah
    Shariati, Shahab
    ANALYTICA CHIMICA ACTA, 2007, 604 (02) : 127 - 133
  • [26] Analysis of Matrine Alkaloids in Human Urine by Hollow Fiber Liquid-phase Microextraction with High-performance Liquid Chromatography
    Han, Dandan
    Row, Kyung Ho
    JOURNAL OF THE KOREAN CHEMICAL SOCIETY-DAEHAN HWAHAK HOE JEE, 2010, 54 (01): : 38 - 42
  • [27] High-performance liquid chromatography analysis of curcumin in rat plasma: application to pharmacokinetics of polymeric micellar formulation of curcumin
    Ma, Zengshuan
    Shayeganpour, Anooshirvan
    Brocks, Dion R.
    Lavasanifar, Afsaneh
    Samuel, John
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (05) : 546 - 552
  • [28] Separation and detection of cyproconazole enantiomers and its stereospecific recognition with chiral stationary phase by high-performance liquid chromatography
    He, Zongzhe
    Wu, Fengxu
    Xia, Weitong
    Li, Lianshan
    Hu, Kunming
    Kaziem, Amir E.
    Wang, Minghua
    ANALYST, 2019, 144 (17) : 5193 - 5200
  • [29] HOLLOW FIBER-BASED LIQUID PHASE MICROEXTRACTION COUPLED WITH HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY FOR EXTRACTION AND DETERMINATION OF VITAMIN D3 IN BIOLOGICAL FLUIDS
    Saber-Tehrani, M.
    Aberoomand-Azar, P.
    Raziee, Maryam
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (03) : 404 - 419
  • [30] Analysis of ketoprofen enantiomers in human and rat plasma by hollow-fiber-based liquid-phase microextraction and chiral mobile-phase additive HPLC
    Hatami, Mehdi
    Farhadi, Khalil
    CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 2013, 91 (12): : 1252 - 1257