The BiPo detector for ultralow radioactivity measurements

被引:0
|
作者
Bongrand, Mathieu [1 ]
机构
[1] Univ Paris 11, CNRS, IN2P3, LAL, F-91405 Orsay, France
关键词
Neutrino; Majorana; Neutrinoless Double Beta Decay; Low Radioactivity; BiPo Processes; Tl-208; Bi-214; MO-100; DECAY;
D O I
10.1063/1.3579559
中图分类号
O59 [应用物理学];
学科分类号
摘要
The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in Tl-208 and Bi-214 for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 m(2) of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-I is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of data collection has been dedicated to the measurement of the radiopurity in Tl-208. After more than one year of background measurement, a surface activity of the scintillators of A(Tl-208) = 1.5 mu Bq/m(2) is reported here. Given this level of background, a larger BiPo3 detector having 3.25 m(2) of active surface area, will able to qualify the radiopurity of the SuperNEMO selenium double beta decay foils with the required sensitivity of A(Tl-208) < 3-4 mu Bq/kg (90% C.L.) with a six month measurement. This detector is actually under construction and will be installed in the Canfranc Underground Laboratory mid 2011.
引用
收藏
页码:49 / 58
页数:10
相关论文
共 50 条
  • [1] The BiPo detector for ultralow radioactivity measurements
    Bongrand, M.
    [J]. Topical Worshop on Low Radioactivity Techniques, 2007, 897 : 14 - 19
  • [2] The BiPo detector
    Cebrian, S.
    [J]. TOPICS IN ASTROPARTICLE AND UNDERGROUND PHYSICS (TAUP2009), 2010, 203
  • [3] Studying of characteristics of the HPGe detector for radioactivity measurements
    Demir, D.
    Eroglu, M.
    Tursucu, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2013, 8
  • [4] An electrostatic radon detector designed for water radioactivity measurements
    Wang, JX
    Andersen, TC
    Simpson, JJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 421 (03): : 601 - 609
  • [5] The BiPo-3 detector
    Loaiza, P.
    Barabash, A. S.
    Basharina-Freshville, A.
    Birdsall, E.
    Blondel, S.
    Blot, S.
    Bongrand, M.
    Boursette, D.
    Brudanin, V.
    Busto, J.
    Caffrey, A. J.
    Calvez, S.
    Cascella, M.
    Cerna, C.
    Chauveau, E.
    Chopra, A.
    De Capua, S.
    Duchesneau, D.
    Durand, D.
    Egorov, V.
    Eurin, G.
    Evans, J. J.
    Fajt, L.
    Filosofov, D.
    Flack, R.
    Garrido, X.
    Gomez, H.
    Guillon, B.
    Guzowski, P.
    Holy, K.
    Hodak, R.
    Huber, A.
    Hugon, C.
    Jeremie, A.
    Jullian, S.
    Kauer, M.
    Klimenko, A.
    Kochetov, O.
    Konovalov, S. I.
    Kovalenko, V.
    Lang, K.
    Lemiere, Y.
    Le Noblet, T.
    Liptak, Z.
    Liu, X. R.
    Lutter, G.
    Macko, M.
    Mamedov, F.
    Marquette, C.
    Maugerk, F.
    [J]. APPLIED RADIATION AND ISOTOPES, 2017, 123 : 54 - 59
  • [6] Absolute radioactivity measurements by the use of a 4πβ-4πγ detector configuration
    Kawada, Y
    Ohtuka, M
    Wang, QW
    Hino, Y
    [J]. APPLIED RADIATION AND ISOTOPES, 2004, 60 (2-4) : 357 - 362
  • [7] Evaluation of HPGe Detector Long Term Performance for Environmental Radioactivity Measurements
    Abdel Aziz, Dalal
    Shabasy, A. M.
    Hassan, H. A.
    El-Meligy, Wafaa
    Diab, H. M.
    [J]. EGYPTIAN JOURNAL OF CHEMISTRY, 2022, 65 (13): : 699 - 705
  • [8] Determination of the HPGe detector efficiency in measurements of radioactivity in extended environmental samples
    Montalvan Olivares, Diango M.
    Manso Guevara, M. V.
    Velasco, Fermin G.
    [J]. APPLIED RADIATION AND ISOTOPES, 2017, 130 : 34 - 42
  • [9] Calibration and Performance of HPGe Detector for Environmental Radioactivity Measurements using LabSOCS
    Shyti, Manjola
    [J]. 10TH JUBILEE CONFERENCE OF THE BALKAN PHYSICAL UNION, 2019, 2075
  • [10] The BiPo low-background detector project
    Vasilyev R.V.
    [J]. Physics of Particles and Nuclei Letters, 2009, 6 (3) : 241 - 245