Monte Carlo calculation of rectal dose when using an endorectal balloon during prostate radiation therapy

被引:0
|
作者
Song, JS
Court, LE
Cormack, RA
机构
[1] Brigham & Womens Hosp, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
关键词
D O I
10.1118/1.1998020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Air‐filled intrarectal balloons can be used to localize and immobilize the prostate for radiation therapy. This project investigates how well the Eclipse treatment planning system (Varian Inc.) includes the effect of this potentially significant heterogeneity on doses to the rectum. Method and Materials: The BEAMnrc/DOSXYZnrc Monte Carlo (MC) codes were used to simulate a 4‐field conformal therapy treatment for patients who have been treated for prostate cancer under an IRB‐approved protocol which includes a 27Gy cone‐down using a rectal balloon. The rectal doses calculated using MC were compared with those from Eclipse using isodose curves, dose‐volume histograms, and wall‐volume histograms. Results: The MC results showed that, for a 27Gy prescription to the 95% isodose line, Eclipse over‐estimates the volume of the rectum receiving more than 26 Gy by 2–10cc and the volume of the rectum receiving between 12–15 Gy by 10–20cc. Conclusion: The differences in the rectal dose calculated by Eclipse and MC are consistent and can be predicted. They can be explained by the scattering behavior of the PA and lateral fields inside the balloon: For each field, the lack of electronic equilibrium reduces the high dose region while the increased electron range widens the low dose region beyond the penumbra. The combined effect of the four fields divides the DVH into two major regions, corresponding to the AP‐PA and lateral fields, and four subregions, corresponding to the scattering behavior of electrons in air. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2017 / 2017
页数:1
相关论文
共 50 条
  • [21] Geant4 Based Monte Carlo Dose Calculation Engine for Radiation Therapy
    Xiao, Shanjie
    Yang, Xue
    Sztejnberg, Manuel
    Jevremovic, Tatjana
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (02) : 775 - 781
  • [22] Rectal dose-volume differences for scanning proton beam therapy with or without an endorectal balloon for the treatment of prostate cancer
    Desai, Anand
    Stoker, Joshua B.
    Wages, Cody A.
    Zhu, X. Ron
    Lee, Andrew
    JOURNAL OF CLINICAL ONCOLOGY, 2013, 31 (06)
  • [23] Fast Monte Carlo dose calculation in proton therapy
    Holmes, Jason
    Feng, Hongying
    Zhang, Lian
    Fix, Michael K.
    Jiang, Steve B.
    Liu, Wei
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (17):
  • [24] Inverse treatment planning for radiation therapy based on fast Monte Carlo dose calculation
    Fippel, M
    Alber, M
    Birkner, M
    Laub, W
    Nüsslin, F
    Kawrakow, I
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 217 - 222
  • [25] A Monte Carlo dose calculation algorithm for proton therapy
    Fippel, M
    Soukup, M
    MEDICAL PHYSICS, 2004, 31 (08) : 2263 - 2273
  • [26] Interfraction Motion of the Full Seminal Vesicles in Prostate Radiation Therapy Using a Daily Endorectal Balloon
    Hollander, A.
    Both, S.
    Vapiwala, N.
    Kirk, M.
    Christodouleas, J.
    Bekelman, J.
    Tochner, Z.
    Deville, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S388 - S388
  • [27] Monte carlo calculation for radiation dose prediction easily predicting monte carlo method for indoor radiation dose (part i)
    Omori T.
    Kato S.
    Kim M.
    Nukatsuka S.
    Journal of Environmental Engineering (Japan), 2016, 81 (727): : 835 - 843
  • [28] COMBINATION OF 3D-ULTRASOUND AND MONTE CARLO DOSE CALCULATION FOR ACCURATE ASSESSMENT OF DOSES DELIVERED DURING DAILY RADIATION THERAPY FOR PROSTATE CANCER
    Cury, F.
    Chen, Y.
    Fraser, D.
    Parker, W.
    Shenouda, G.
    Souhami, L.
    Faria, S.
    Duclos, M.
    David, M.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S30 - S30
  • [29] Dosimetric and deformation effects of image-guided interventions during stereotactic body radiation therapy of the prostate using an endorectal balloon
    Jones, Bernard L.
    Gan, Gregory
    Diot, Quentin
    Kavanagh, Brian
    Timmerman, Robert D.
    Miften, Moyed
    MEDICAL PHYSICS, 2012, 39 (06) : 3080 - 3088
  • [30] Rectal dose sparing with a balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer
    Patel, RR
    Orton, N
    Tomé, WA
    Chappell, R
    Ritter, MA
    RADIOTHERAPY AND ONCOLOGY, 2003, 67 (03) : 285 - 294