Wet-Gas Flow Modeling for the Straight Section of Throat-Extended Venturi Meter

被引:26
|
作者
Xu, Lijun [2 ]
Zhou, Wanlu [2 ]
Li, Xiaomin [1 ]
Wang, Minghao [2 ]
机构
[1] Beihang Univ, Sch Chem & Environm, Beijing 100191, Peoples R China
[2] Beihang Univ, Sch Instrument Sci & Optoelect Engn, Beijing 100191, Peoples R China
关键词
Fitting error; flow modeling; separated flow; Venturi meter; wet-gas metering; 2-PHASE FLOW;
D O I
10.1109/TIM.2011.2117190
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the wet-gas flow modeling for the straight section of a throat-extended Venturi meter was studied. Based on the separated-flow theory, a flow model was presented. The relationship between the fluctuating properties of the differential pressure (DP) over the straight section and the quality of the wet-gas flow was also studied, and a flow model of the fluctuation of the DP for wet-gas metering was established. Experiments were carried out within a system pressure range of 0.26-0.86 MPa, a gas volumetric flowrate range of 80-120 m(3)/h, a water volumetric flowrate range of 1.3-4.5 m(3)/h, and a quality range of 0.07-0.36. It was obtained that the root mean square of the relative errors of the DP over the straight section calculated from the separated-flow-theory-based model was 8.82% and that of the quality calculated from the fluctuating-property-related model was 8.77%.
引用
收藏
页码:2080 / 2087
页数:8
相关论文
共 50 条
  • [21] CONDENSATE FLOW IN WET-GAS LINES CAN BE PREDICTED
    CUNLIFFE, RS
    OIL & GAS JOURNAL, 1978, 76 (44) : 100 - &
  • [22] Wet Gas Metering Using a Venturi-meter and Neural Networks
    Xu, Lijun
    Li, Hui
    Tang, Shaliang
    Tan, Cheng
    Hu, Bo
    2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 761 - +
  • [23] Study on the similarity of wet gas pressure drop in long-throat Venturi
    Wu, Haitao
    Xu, Ying
    Wang, Jinghan
    Zhang, Tao
    Wang, Huaxiang
    FLOW MEASUREMENT AND INSTRUMENTATION, 2019, 68
  • [24] Vertically installed Venturi tubes for wet-gas flow measurement: Possible improvements to ISO/TR 11583 to extend its range of applicability
    Graham, E. M.
    Reader-Harris, M.
    Chinello, G.
    Harkins, K.
    Bowman, N.
    Wales, L.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2020, 74
  • [25] On fluctuation of the dynamic differential pressure signal of Venturi meter for wet gas metering
    Xu, LJ
    Xu, H
    Dong, F
    Zhang, T
    FLOW MEASUREMENT AND INSTRUMENTATION, 2003, 14 (4-5) : 211 - 217
  • [26] Wet Gas Metering Using a Venturi-Meter and Support Vector Machines
    Xu, Lijun
    Tang, Shaliang
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 1125 - 1129
  • [27] A wet gas meter for gas/condensate flow measurement
    Lund, JS
    Tait, AR
    Clark, S
    9TH INTERNATIONAL CONFERENCE ON MULTIPHASE '99: FRONTIER TECHNOLOGY COMES OF AGE, 1999, (35): : 303 - 315
  • [28] A new correlation for wet gas flow rate measurement with Venturi meter based on two-phase mass flow coefficient
    He, Denghui
    Bai, Bofeng
    MEASUREMENT, 2014, 58 : 61 - 67
  • [29] Over-reading modeling of the ultrasonic flow meter in wet gas measurement
    Xu, Ying
    Yu, Peining
    Zhu, Zicheng
    Yuan, Chao
    Zhang, Tao
    MEASUREMENT, 2017, 98 : 17 - 24
  • [30] Effect of Pressure on the Wave Behavior in Horizontal Wet-gas Annular Flow
    Zhu, Yan
    Zeng, Qiaoqiao
    Niu, Lina
    Li, Xiaoting
    Zhao, Ning
    Fang, Lide
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 444 - 449