Wet-Gas Flow Modeling for the Straight Section of Throat-Extended Venturi Meter

被引:26
|
作者
Xu, Lijun [2 ]
Zhou, Wanlu [2 ]
Li, Xiaomin [1 ]
Wang, Minghao [2 ]
机构
[1] Beihang Univ, Sch Chem & Environm, Beijing 100191, Peoples R China
[2] Beihang Univ, Sch Instrument Sci & Optoelect Engn, Beijing 100191, Peoples R China
关键词
Fitting error; flow modeling; separated flow; Venturi meter; wet-gas metering; 2-PHASE FLOW;
D O I
10.1109/TIM.2011.2117190
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the wet-gas flow modeling for the straight section of a throat-extended Venturi meter was studied. Based on the separated-flow theory, a flow model was presented. The relationship between the fluctuating properties of the differential pressure (DP) over the straight section and the quality of the wet-gas flow was also studied, and a flow model of the fluctuation of the DP for wet-gas metering was established. Experiments were carried out within a system pressure range of 0.26-0.86 MPa, a gas volumetric flowrate range of 80-120 m(3)/h, a water volumetric flowrate range of 1.3-4.5 m(3)/h, and a quality range of 0.07-0.36. It was obtained that the root mean square of the relative errors of the DP over the straight section calculated from the separated-flow-theory-based model was 8.82% and that of the quality calculated from the fluctuating-property-related model was 8.77%.
引用
收藏
页码:2080 / 2087
页数:8
相关论文
共 50 条
  • [1] Wet gas flow modeling for the straight section of throat-extended Venturi meter
    Zhou, Wanlu
    Xu, Lijun
    Li, Xiaomin
    2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,
  • [2] Modeling wet-gas annular/dispersed flow through a Venturi
    van Werven, M
    van Maanen, HRE
    Ooms, G
    Azzopardi, BJ
    AICHE JOURNAL, 2003, 49 (06) : 1383 - 1391
  • [3] Gas-Liquid Two-Phase Flow Measurement With Throat-Extended Venturi Meter Based on Differential Pressure Ratios and Fluctuations
    Suo, Peng
    Sun, Jiangtao
    Shi, Shiying
    Sun, Shijie
    He, Feng
    Zhang, Xiaokai
    Shen, Mengxian
    Li, Xiaolin
    Li, Jinfei
    Xu, Lijun
    IEEE Transactions on Instrumentation and Measurement, 2024, 73
  • [4] Modeling of wet-gas flow through horizontal Venturi based on void fraction
    Yu, Peining
    Xu, Ying
    Zhang, Tao
    Wei, Jing
    Ba, Xili
    Li, Jing
    Qin, Zigeng
    Huagong Xuebao/CIESC Journal, 2014, 65 (12): : 4692 - 4698
  • [5] Wet gas flow modeling for a vertically mounted Venturi meter
    Xu, Lijun
    Zhou, Wanlu
    Li, Xiaomin
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (04)
  • [6] Modeling of wet gas flow in vertically mounted Venturi meter
    Zhou, Wanlu
    Xu, Lijun
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (05): : 1120 - 1125
  • [7] Venturi meter performance in wet gas flow
    DeLeeuw, H
    8TH INTERNATIONAL CONFERENCE ON MULTIPHASE '97 - HOW DEEP? HOW FAR? HOW SOON?, 1997, (24): : 567 - 582
  • [8] Wet gas metering by using a long-throat Venturi meter
    Xu, Lijun
    Li, Hui
    Xu, Jian
    SEVENTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND CONTROL TECHNOLOGY: SENSORS AND INSTRUMENTS, COMPUTER SIMULATION, AND ARTIFICIAL INTELLIGENCE, 2008, 7127
  • [9] Numerical investigation of wet gas flow in Venturi meter
    He, Denghui
    Bai, Bofeng
    FLOW MEASUREMENT AND INSTRUMENTATION, 2012, 28 : 1 - 6
  • [10] Extended Throat Venturi Based Flow Meter for Optimization of Oil Production Process
    Karimi, Muhammad Akram
    Arsalan, Muhammad
    Shamim, Atif