Simultaneous B1 and T1 mapping using spiral multislice variable flip angle acquisitions for whole-brain coverage in less than one minute

被引:4
|
作者
Heule, Rahel [1 ,2 ,3 ]
Pfeuffer, Josef [4 ]
Meyer, Craig H. [5 ]
Bieri, Oliver [1 ,2 ]
机构
[1] Univ Basel, Univ Basel Hosp, Dept Radiol, Div Radiol Phys, Basel, Switzerland
[2] Univ Basel, Dept Biomed Engn, Basel, Switzerland
[3] Max Planck Inst Biol Cybernet, High Field Magnet Resonance, Max Planck Ring 11, D-72076 Tubingen, Germany
[4] Siemens Healthcare, Applicat Dev, Erlangen, Germany
[5] Univ Virginia, Dept Biomed Engn, Charlottesville, VA USA
基金
瑞士国家科学基金会;
关键词
B-1; T-1; variable flip angle (VFA); spiral trajectories; steady-state preparation; whole-brain coverage; RF PULSE; ACCURACY; FIELD;
D O I
10.1002/mrm.27544
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Variable flip angle (VFA)-based T-1 quantification techniques are highly sensitive to B-1 inhomogeneities and to residual T-2 dependency arising from incomplete spoiling. Here, a rapid spiral VFA acquisition scheme with high spoiling efficiency is proposed for simultaneous whole-brain B-1 and T-1 mapping. Methods: VFA acquisitions at 2 different flip angles are performed to quantify T-1 using a steady-state prepared spiral 2D multislice spoiled gradient-echo sequence with the acquisition of 10 and 20 spiral interleaves at 1.5T and 3T, respectively. Additionally, parallel imaging acceleration of factor 2 is investigated at 3T. The free induction decay induced by the preparation pulse is sampled by a single-shot spiral readout to quantify B-1. Results: The in vitro and in vivo validations yielded good agreement between the derived spiral VFA B-1 and the acquired reference B-1 maps as well as between the B-1-corrected spiral VFA T-1 and the reference T-1 maps. The spiral VFA acquisitions in the human brain delivered artifact-free B-1 and T-1 maps and demonstrated high reproducibility at 1.5T and 3T. Conclusion: Reliable simultaneous spiral VFA B-1 and T-1 quantification was feasible with acquisition times of <1 min for whole-brain coverage at clinically relevant resolution.
引用
收藏
页码:1876 / 1889
页数:14
相关论文
共 43 条
  • [1] Snapshot whole-brain T1 relaxometry using steady-state prepared spiral multislice variable flip angle imaging
    Heule, Rahel
    Pfeuffer, Josef
    Bieri, Oliver
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 856 - 866
  • [2] Silent T1 mapping using the variable flip angle method with B1 correction
    Ljungberg, Emil
    Wood, Tobias
    Solana, Ana Beatriz
    Kolind, Shannon
    Williams, Steven C. R.
    Wiesinger, Florian
    Barker, Gareth J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 813 - 824
  • [3] Simultaneous T1 and B1+ Mapping Using Reference Region Variable Flip Angle Imaging
    Sung, Kyunghyun
    Saranathan, Manojkumar
    Daniel, Bruce L.
    Hargreaves, Brian A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (04) : 954 - 961
  • [4] T1 Mapping Using Variable Flip Angle SPGR Data With Flip Angle Correction
    Liberman, Gilad
    Louzoun, Yoram
    Ben Bashat, Dafna
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (01) : 171 - 180
  • [5] The application of B1 inhomogeneity-corrected variable flip angle T1 mapping for assessing liver fibrosis
    Zou, Jie
    Jiang, Yanli
    Fan, Fengxian
    Yang, Pin
    Gan, Tiejun
    Yang, Tingli
    Li, Min
    Ding, Yuan
    Wang, Shaoyu
    Zhang, Jing
    [J]. MAGNETIC RESONANCE IMAGING, 2024, 113
  • [6] Spiral 3DREAM sequence for fast whole-brain B1 mapping
    Niesen, Svenja
    Veldmann, Marten
    Ehses, Philipp
    Stoecker, Tony
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2024,
  • [7] Uncertainty in T1 mapping using the variable flip angle method with two flip angles
    Schabel, Matthias C.
    Morrell, Glen R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (01): : N1 - N8
  • [8] Simultaneous variable flip angle-actual flip angle imaging method for improved accuracy and precision of three-dimensional T1 and B1 measurements
    Hurley, Samuel A.
    Yarnykh, Vasily L.
    Johnson, Kevin M.
    Field, Aaron S.
    Alexander, Andrew L.
    Samsonov, Alexey A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 54 - 64
  • [9] Tissue sodium concentration and sodium T1 mapping of the human brain at 3 T using a Variable Flip Angle method
    Coste, Arthur
    Boumezbeur, Fawzi
    Vignaud, Alexandre
    Madelin, Guillaume
    Reetz, Kathrin
    Le Bihan, Denis
    Rabrait-Lerman, Cecile
    Romanzetti, Sandro
    [J]. MAGNETIC RESONANCE IMAGING, 2019, 58 : 116 - 124
  • [10] Three-Dimensional GRE T1ρ mapping of the brain using tailored variable flip-angle scheduling
    Johnson, Casey P.
    Thedens, Daniel R.
    Kruger, Stanley J.
    Magnotta, Vincent A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (03) : 1235 - 1249