Light scattering properties of bovine muscle tissue in vitro, a comparison of methods

被引:0
|
作者
Zijp, JR [1 ]
ten Bosch, JJ [1 ]
机构
[1] Univ Groningen, Mat Tech Lab, NL-9712 KZ Groningen, Netherlands
关键词
tissue optical properties; muscular tissue;
D O I
10.1117/12.334362
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We measured the light scattering properties of muscular tissue using several methods, and compared the obtained results. Calculation of the extinction coefficient by using collimated transmission measurements and applying Beer's law is not appropriate. Probably surface roughness of the sample disables the calculation of the extinction coefficient from such measurements. From angular intensity measurements we found a scattering asymmetry parameter g = 0.96. In fresh samples the optical diffusion constant D depends on the orientation with respect to the longitudinal direction of the muscular cells. From the D values we calculated s' perpendicular to the longitudinal direction as 0.19 mm(-1) (at 543 nm), 0.39 mm(-1) (at 594 nm) and 0.59 mm(-1) (at 632 nm). The values for D measured from samples that were frozen and thawed did not show dependence on orientation.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 50 条
  • [1] Optical properties of bovine muscle tissue in vitro; a comparison of methods
    Zijp, JR
    ten Bosch, JJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10): : 3065 - 3081
  • [2] Comments on the paper 'Optical properties of bovine muscle tissue in vitro;: a comparison of methods'
    Marchesini, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (04): : L7 - L7
  • [3] Reply to 'Comments on the paper 'Optical properties of bovine muscle tissue in vitro;: a comparison of methods'
    Zijp, JR
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (04): : L8 - L8
  • [4] Light-scattering methods for tissue diagnosis
    Steelman, Zachary A.
    Ho, Derek S.
    Chu, Kengyeh K.
    Wax, Adam
    OPTICA, 2019, 6 (04): : 479 - 489
  • [5] A comparison between rigorous light scattering methods
    Davidson, M
    Kleemann, BH
    Bischoff, J
    OPTICAL MICROLITHOGRAPHY X, 1997, 3051 : 606 - 619
  • [6] Light scattering by single erythrocyte: Comparison of different methods
    Wriedt, T
    Hellmers, J
    Eremina, E
    Schuh, R
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2006, 100 (1-3): : 444 - 456
  • [7] Comparison of the light scattering methods using the spherical basis
    V. G. Farafonov
    A. A. Vinokurov
    V. B. Il’in
    Optics and Spectroscopy, 2007, 102 : 927 - 938
  • [8] Comparison of the light scattering methods using the spherical basis
    Farafonov, V. G.
    Vinokurov, A. A.
    Il'in, V. B.
    OPTICS AND SPECTROSCOPY, 2007, 102 (06) : 927 - 938
  • [9] A comparison of rapid bovine spongiform encephalopathy testing methods on autolyzed bovine brain tissue
    Wear, A
    Henderson, K
    Webster, K
    Patel, I
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2005, 17 (02) : 99 - 102
  • [10] CHEMICAL PROPERTIES OF THE LIGHT-SCATTERING A SIGNAL FROM BOVINE DISKS
    UHL, R
    BORYS, T
    ABRAHAMSON, EW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1979, : 22 - 22