Evaluation of radiation dose to pediatric models from whole body PET/CT imaging

被引:6
|
作者
Mohammadi, Najmeh [1 ]
Akhlaghi, Parisa [2 ]
机构
[1] Sahand Univ Technol, Fac Sci, Phys Dept, Tabriz 513351996, Iran
[2] Tabriz Univ Med Sci, Fac Med, Dept Med Phys, Tabriz, Iran
来源
关键词
dosimetry; Monte Carlo; pediatrics; PET; CT; voxel phantoms; F-18-FDG PET; UF SERIES; CHILDREN; CT; GUIDELINES; DOSIMETRY; EXPOSURE; PHANTOMS;
D O I
10.1002/acm2.13545
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Positron emission tomography (PET)/computed tomography (CT) is a well-known modality for the diagnosis of various diseases in children and adult patients. On the other hand, younger patients are more radiosensitive than adults, so there are concerns about the level of ionizing radiation exposure in pediatric whole body PET/CT imaging. In this regard, comprehensive specific radiation dosimetry for whole body PET/CT imaging is highly desired for different ages, sizes, and shapes. Therefore, in this study, organ absorbed doses were evaluated for pediatric voxel models from 4 to 14 years old and compared with those of ICRP phantoms. Monte Carlo calculation was performed to evaluate S-value, absorbed dose, and effective dose from F-18-FDG radiotracers and whole body CT scan for different computational models, including 4- to 14-year-old phantoms. The results showed that the S-value and, therefore, absorbed dose of F-18-FDG strongly depended on the phantom anatomy. These variations were justified by the distance between source and target organs. Moreover, on average, the absorbed doses from whole body CT scans were 13.5 times lower than those from F-18-FDG for all organs. According to the results, various anatomies and ages should be considered for accurate dose evaluation. These data can be used for specific risk assessment of the pediatric population in clinical nuclear imaging.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Effective dose Estimation in Whole Body 18F-FDG PET/CT Imaging
    Karimipourfard, M.
    Sina, S.
    Shobeiry, M.
    Alavi, M. S.
    Faghihi, R.
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (18) : 1444 - 1449
  • [22] Optimal Dose for Whole-Body 18F-Fluorodeoxyglucose PET/CT Imaging
    Kesner, Adam L.
    Bagrosky, Brian M.
    Kwak, Jennifer J.
    Koo, Phillip J.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2014, 11 (09) : 920 - 922
  • [23] Radiation dose estimates for 11C-acetate whole body PET imaging.
    Seltzer, MA
    Sparks, R
    Stout, DB
    Satyamurthy, N
    Dahlbom, M
    Phelps, ME
    Barrio, JR
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 242P - 242P
  • [24] Weight-Based, Low-Dose Pediatric Whole-Body PET/CT Protocols
    Alessio, Adam M.
    Kinahan, Paul E.
    Manchanda, Vivek
    Ghioni, Victor
    Aldape, Lisa
    Parisi, Marguerite T.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (10) : 1570 - 1578
  • [25] Radiation Dose Optimization of a Dual Tracer PET/CT Protocol for Multiple Myeloma: a Whole Body Ultra-Low Dose CT
    Prieto, E.
    Marti-Climent, J. M.
    Aquerreta, J. D.
    Moran, V.
    Irazola, L.
    Bastidas, J. F.
    Soriano, I.
    Rosales, J. J.
    Rodriguez-Otero, P.
    Garcia-Velloso, M. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S81 - S81
  • [26] ASSOCIATED FACTORS AFFECTING RADIATION DOSE IN 18F-FDG WHOLE BODY PET/CT
    Alkhybari, E.
    McEntee, M.
    Willowson, K.
    Kench, P.
    INTERNAL MEDICINE JOURNAL, 2019, 49 : 8 - 8
  • [27] Estimation of radiation dose to patients from 18FDG whole body PET/CT investigations using dynamic PET scan protocol
    Kaushik, Aruna
    Jaimini, Abhinav
    Tripathi, Madhavi
    D'Souza, Maria
    Sharma, Rajnish
    Mondal, Anupam
    Mishra, Anil K.
    Dwarakanath, Bilikere S.
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2015, 142 : 720 - 730
  • [28] Whole body PET/CT imaging staging for orbital lymphoma
    Roe, RH
    Kurli, M
    Trivedi, G
    Iacob, CE
    Tena, LB
    Finger, PT
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [29] Does Whole Body CT is Necessary for PET/CT Evaluation of SPN
    Can, N.
    Unlu, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S421 - S421
  • [30] 18F-FDGwhole body PET/CT: evaluation of effective dose in pediatric patients
    Zito, F.
    Galetta, G.
    Rossi, L.
    Florimonte, L.
    Orunesu, E.
    Castellani, M.
    Canzi, C.
    Voltini, F.
    Benti, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S270 - S270