Development of combined fouling model in a membrane bioreactor

被引:14
|
作者
Kim, M. J. [1 ]
Yoo, G. Y. [1 ]
Yoo, C. K. [1 ]
机构
[1] Kyung Hee Univ, Coll Engn, Ctr Environm Studies, Dept Environm Sci & Engn, Yongin 446701, Gyeonggi Do, South Korea
关键词
combined fouling model; membrane bioreactor; fouling mechanism; membrane filtration; membrane chemical cleaning interval; MBR efficient operation; REMOVAL;
D O I
10.1002/apj.589
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Membrane bioreactor (MBR) system has recently become very important in wastewater treatment. However, membrane capacity during the filtration process is reduced by fouling, which is the deposition or adsorption of particles on the membrane surface or inside of the pores. For an efficient operation of MBR system, prediction of MBR fouling progress and determination of proper membrane chemical cleaning interval is necessary. Until now, four blocking models, which are complete blocking, intermediate blocking, cake filtration, and standard blocking, have typically been used to describe and predict the MBR fouling. In this study, a new combined membrane fouling model, based on the four constant flowrate blocking models, is developed to explain the combined effects of the different fouling mechanisms. This model is assumed to be more accurate in determining the chemical cleaning interval by considering variation of dominant fouling mechanisms in the filtration process. The combined fouling model is applied to data sets from a pilot-scale MBR for monitoring the variations of dominant fouling stage. By checking temporal variations of root mean square error (RMSE) values from fitting trans-membrane pressure data to four constant flowrate blocking models, the dominant fouling mechanism by each fouling stage is determined. In particular, the fouling prediction result by the new combined model of three fouling mechanisms, which are complete blocking, cake filtration, and intermediate blocking, excluding the standard blocking model has better predictive accuracy than the combined model of four mechanisms, which remarkably reduced the RMSE from 10.48 to 1.73. On the basis of the improvement, the new combined model with three mechanisms has the potential to predict MBR fouling process and to determine the optimum interval for membrane chemical cleaning. Our results would contribute the economic operation of MBR plants by suggesting the appropriate membrane cleaning interval with the filtration capacity maintained at optimal level. (C) 2011 Curtin University of Technology and John Wiley & Sons, Ltd.
引用
下载
收藏
页码:423 / 432
页数:10
相关论文
共 50 条
  • [21] Membrane fouling related to microbiological characteristics in membrane bioreactor
    School of Mechanical Engineering and Automation, Northeastern University, Shenyang 110004, China
    Huaxue Gongcheng, 2008, 11 (43-46+54):
  • [22] Membrane fouling control in the moving carriershybrid membrane bioreactor
    Li, Zheng
    Qi, Pei-Shi
    Chen, Zhao-Bo
    Wang, Wen-Bin
    Zhongguo Kuangye Daxue Xuebao/Journal of China University of Mining and Technology, 2008, 37 (06): : 814 - 818
  • [23] Membrane fouling control in an integrated membrane-bioreactor
    Liu, Rui
    Huang, Xia
    Wang, Chengwen
    Qian, Yi
    Zhang, Miaomiao
    Huanjing Kexue/Environmental Science, 2000, 21 (02): : 58 - 61
  • [24] Membrane fouling control in anaerobic submerged membrane bioreactor
    Aslan, Mustafa
    Saatci, Yusuf
    Hanay, Ozge
    Hasar, Halil
    DESALINATION AND WATER TREATMENT, 2014, 52 (40-42) : 7520 - 7530
  • [25] Performance and membrane fouling characteristics of a combined biofilm and membrane bioreactor for treatment of fluorescent whitening agent wastewater
    Liang, Zhiwei
    Du, Ping
    Yang, Shangyuan
    Li, Xin
    Qian, Yichao
    ENVIRONMENTAL TECHNOLOGY, 2014, 35 (11) : 1427 - 1435
  • [26] A comparison study on membrane fouling in a sponge-submerged membrane bioreactor and a conventional membrane bioreactor
    Deng, Lijuan
    Guo, Wenshan
    Ngo, Huu Hao
    Zhang, Jian
    Liang, Shuang
    Xia, Siqing
    Zhang, Zhiqiang
    Li, Jianxin
    BIORESOURCE TECHNOLOGY, 2014, 165 : 69 - 74
  • [27] Effects of pharmaceuticals on membrane bioreactor: Review on membrane fouling mechanisms and fouling control strategies
    Sengar, Ashish
    Vijayanandan, Arya
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 808
  • [28] Different fouling mechanisms of hollow fiber membrane bioreactor and flat sheet membrane bioreactor
    Xing, Kai
    Zhang, Hong-Wei
    Long, Shu-Yong
    Sun, Kai
    Wang, Liang
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2009, 42 (11): : 1028 - 1033
  • [29] Biomass Characteristics and Their Effect on Membrane Bioreactor Fouling
    Gkotsis, Petros K.
    Zouboulis, Anastasios I.
    MOLECULES, 2019, 24 (16):
  • [30] Fouling control of a metal membrane bioreactor with ozone
    Xie, Yuanhua
    Yuan, Chunli
    Lv, Liting
    Chai, Tianyu
    Bai, Bing
    Fan, Mingxiang
    You, Meiyan
    Han, Jin
    Zhu, Tong
    Energy Education Science and Technology Part A: Energy Science and Research, 2014, 32 (01): : 615 - 624