Efficacy and safety of transvenous lead extraction in the Chinese octogenarian patients

被引:2
|
作者
Zhou, Xu [1 ]
Ze, Feng [2 ]
Li, Xuebin [2 ]
Wang, Bin [1 ]
机构
[1] Shantou Univ, Med Coll, Affiliated Hosp 1, Dept Cardiol, Shantou, Guangdong, Peoples R China
[2] Peking Univ, Dept Cardiac Electrophysiol, Peoples Hosp, Beijing, Peoples R China
关键词
octogenarians; pacemaker; procedure outcomes; transvenous lead extraction; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; PACEMAKER; EXPERIENCE; OUTCOMES; TRENDS;
D O I
10.1002/clc.23629
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Managing elderly patients with infection or malfunction deriving from a cardiac implantable electronic device (CIED) may be challenging. We report the safety and effectiveness of transvenous lead extraction in Chinese octogenarian patients. Hypothesis Transvenous lead extraction can be performed safely and successfully in the Chinese octogenarians. Methods We retrospectively identified all patients who underwent TLE at our institution between March 2013 and January 2021. This population was divided into the following two groups based solely on age: octogenarians and non-octogenarians. These two groups were compared on the basis of several characteristics and clinical outcomes. Results Consecutive 1106 patients were analyzed, including 184 (16.6%) octogenarians and 922(83.4%) non-octogenarians. The octogenarians presented more comorbidities. A total of 378 leads and 2004 leads were removed from the patients in the octogenarian group and non-octogenarian group, respectively. The mean lead implant duration was 6.1 +/- 5.1 and 5.8 +/- 4.6 years for octogenarians and non-octogenarians (p = 0.296). The majority of the patients in both groups underwent TLE through the femoral approach (67.5% vs 61.6%, p = 0.14). The complete procedure success rate was similar between the octogenarian and non-octogenarian group (96.7% vs.95.3%, p = 0.39). There were no differences with respect to the proportion of minor, major complications and deaths. Long-term mortality (median time 3.3 years) after TLE in octogenarians was significantly higher compared with younger individuals. Conclusions At experienced centers, transvenous lead extraction can be performed safely in Chinese octogenarians with procedural success rate and complication rate comparable to younger individuals.
引用
收藏
页码:971 / 977
页数:7
相关论文
共 50 条
  • [31] Safety and efficacy of biodegradable stents in octogenarian patients with esophageal achalasia
    Hernandez-Mondragon, Oscar
    Garcia Contreras, Luis
    Michel Pineda, Omar
    Blanco-Velasco, Geraro
    Murcio-Perez, Enrique
    ENDOSCOPY INTERNATIONAL OPEN, 2021, 09 (06) : E756 - E766
  • [32] Analysis of electrical lead failures in patients referred for transvenous lead extraction procedures
    Zabek, Andrzej
    Boczar, Krzysztof
    Debski, Maciej
    Ulman, Mateusz
    Matusik, Pawel T.
    Lelakowski, Jacek
    Malecka, Barbara
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (09): : 1217 - 1223
  • [33] Lead material retention and clinical outcomes in patients undergoing transvenous lead extraction
    Hussein, A.
    Nimri, N.
    Barakat, A.
    Tarakji, K.
    Saliba, W.
    Rickard, J.
    Callahan, T.
    Martin, D.
    Kanj, M.
    Baranowski, B.
    Cantillon, D.
    Niebauer, M.
    Lindsay, B.
    Wilkoff, B.
    Wazni, O.
    EUROPEAN HEART JOURNAL, 2018, 39 : 684 - 685
  • [34] Performance of the padit score in patients undergoing transvenous lead extraction
    Dias Ferreira Reis, J. P.
    Valente, B.
    Ferreira, V
    Castelo, A.
    Portugal, G.
    Monteiro, A.
    Lousinha, A.
    Silva Cunha, P.
    Oliveira, M.
    Cruz Ferreira, R.
    EUROPEAN HEART JOURNAL, 2020, 41 : 830 - 830
  • [35] Efficacy and safety of capsule endoscopy in octogenarian patients: a retrospective study
    Pezzoli, Alessandro
    Guarino, Matteo
    Fusetti, Nadia
    Pizzo, Elena
    Simoni, Marzia
    Simone, Loredana
    Cifala, Viviana
    Solimando, Riccardo
    Perna, Benedetta
    Testino, Gianni
    Pellicano, Rinaldo
    Caio, Giacomo
    Lungaro, Lisa
    Caputo, Fabio
    Zoli, Giorgio
    Merighi, Alberto
    De Giorgio, Roberto
    MINERVA GASTROENTEROLOGY, 2023, 69 (03): : 388 - 395
  • [36] Transvenous Lead Extraction in Patients With Arrhythmogenic Right Ventricular Cardiomyopathy
    Barakat, Amr F.
    Zmaili, Mohammad A.
    Tarakji, Khaldoun G.
    Shah, Shailee
    Rehman, Karim Abdur
    Martin, David O.
    Brunner, Michael P.
    Saliba, Walid, I
    Kanj, Mohamed
    Ballout, Jad
    Baranowski, Bryan
    Cantillon, Daniel
    Niebauer, Mark
    Callahan, Thomas
    Dresing, Thomas
    Rickard, John
    Lindsay, Bruce D.
    Wilkoff, Bruce L.
    Wazni, Oussama M.
    Hussein, Ayman A.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (06) : 665 - 670
  • [37] SAFETY AND EFFICACY OF TRANSVENOUS EXTRACTION OF PACEMAKER AND CARDIOVERTER-DEFIBRILLATOR LEADS
    Vefali, H.
    Durkin, M.
    Singh, A.
    Agrawal, S.
    Nanda, S.
    Traub, D.
    Shirani, J.
    CARDIOLOGY, 2016, 134 : 331 - 331
  • [38] Transvenous lead extraction in patients with prior extraction procedures: Procedural profiles and outcomes
    Hutt, Erika
    Diab, Mohamed
    Wazni, Oussama M.
    Kaur, Simrat
    Tarakji, Khaldoun G.
    Saliba, Walid I.
    Kanj, Mohamed
    Cantillon, Daniel
    Rickard, John
    Varma, Niraj
    Callahan, Thomas
    Martin, David O.
    Niebauer, Mark
    Dresing, Thomas
    Chung, Mina
    Wilkoff, Bruce L.
    Hussein, Ayman A.
    HEART RHYTHM, 2020, 17 (11) : 1904 - 1908
  • [39] Transvenous lead extraction in young patients. Specificity and disparateness
    Kutarski, A.
    Jachec, W.
    Tomasik, A.
    Czajkowski, M.
    Polewczyk, M.
    Tuchalska, A.
    Polewczyk, A.
    EUROPEAN HEART JOURNAL, 2016, 37 : 19 - 19
  • [40] Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy
    Stefanczyk, Pawel
    Nowosielecka, Dorota
    Polewczyk, Anna
    Jachec, Wojciech
    Glowniak, Andrzej
    Kosior, Jaroslaw
    Kutarski, Andrzej
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2023, 20 (01)