Research on the Temperature Rise Characteristics of Medium-Voltage Switchgear under Different Operation Conditions

被引:4
|
作者
Zhao, Lihua [1 ]
Wu, Yuezheng [1 ]
Huang, Xiaolong [1 ]
Hong, Guo [1 ]
Ren, Junwen [1 ]
Ning, Wenjun [1 ]
Wang, Lijun [1 ]
Sun, Tao [1 ]
Yang, Shangyu [1 ]
机构
[1] Sichuan Univ, Coll Elect Engn, Chengdu 610065, Peoples R China
关键词
flow filed; temperature field; C4F7N; CO2 mixed gas; SF6; gas; multi-physics simulation; GAS;
D O I
10.1002/tee.23553
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
SF6 is a greenhouse gas. Finding an alternative gas for SF6 has become an urgent problem in the switch field. In order to explore the feasibility of replacing SF6 gas with dry air directly, CO2 and C4F7N/CO2 mixed gas, based on the KYN28-12 medium voltage switchgear, the finite element method was used to solve the three-dimensional coupled multi-physics of the switchgear in this paper. From the angle of the temperature field and flow field, the temperature rise characteristics under different operation conditions were analyzed. The results showed that the temperature field and flow field distribution under the four gases were similar. Among them, the temperature rise of SF6 gas was the smallest, followed by the C4F7N/CO2 mixed gas, CO2 and dry air. The flow rate of SF6 gas was the lowest, about 0.11 m/s. The flow velocities of other gases were relatively close. When the switchgear was filled with the same gas, as the inflation pressure increased, the temperature rise of the switchgear decreased and the gas flow rate also dropped to a certain extent. The temperature field and flow field of the switchgear under the C4F7N/CO2 mixed gas at 0.2 Mpa were similar to those under the 0.1 Mpa SF6 gas. Under the C4F7N/CO2 mixed gas, the contact failure of the plum contact made the temperature rise of the switchgear increase overall. The maximum temperature rise point transferred to the contact failure. The temperature rise further rose with the increase of the contact failure degree. The gas flow rate also greatly increased with the failure degree elevated. From the perspective of temperature rise, the C4F7N/CO2 mixed gas has the possibility of being applied in the electrical equipment under the premise of meeting the insulation conditions. (c) 2022 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
引用
收藏
页码:654 / 664
页数:11
相关论文
共 50 条
  • [41] An Approach to Monitor Medium Voltage Switchgear Plum Contact Connections Based on Temperature Rise Index
    Kejani, Mohsen Taghizadeh
    Razi-Kazemi, Ali A.
    Khalkhali, Seyed Hamid
    Heidary, Poorya
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [42] H SYSTEM - NEW GENERATION OF SF6 MEDIUM-VOLTAGE SWITCHGEAR
    SCHAUMANN, R
    POOLE, D
    BROWN BOVERI REVIEW, 1977, 64 (11): : 644 - 649
  • [43] The idea of system control and monitoring of a complete medium-voltage switchgear with solid insulation
    Shul’ga R.N.
    Shul’ga A.R.
    Kovalev D.I.
    Khrenov S.I.
    Koshelev M.A.
    Russian Electrical Engineering, 2017, 88 (8) : 509 - 514
  • [44] DESIGN AND USE OF PROTECTION-CLASS ROGOWSKI COILS FOR MEDIUM-VOLTAGE SWITCHGEAR
    Broderick, Sean
    Pestell, Charles
    Kumar, Nallan
    Payne, Jim
    2023 IEEE IAS PETROLEUM AND CHEMICAL INDUSTRY TECHNICAL CONFERENCE, PCIC, 2023, : 67 - 76
  • [45] A Simple Operation Approach for Modular Multilevel Converter Under Grid Voltage Swell in Medium-Voltage Microgrids
    Xiao, Qian
    Jin, Yu
    Chen, Linglin
    Yu, Xiaodan
    Jia, Hongjie
    Liu, Huiqiao
    Teodorescu, Remus
    Blaabjerg, Frede
    IEEE ACCESS, 2019, 7 : 147280 - 147291
  • [46] Study on Temperature Rise Characteristics of GIS Disconnector Under Different Operating Conditions
    Zhao, Lihua
    Wang, Zelong
    Zhu, Haiyi
    Hong, Guo
    Ren, Junwen
    Long, Wei
    Huang, Xiaolong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (06) : 3601 - 3610
  • [47] Research of noise characteristics for 10-kV medium-voltage power lines
    Tao, Zheng
    Yang Xiaoxian
    Zhang Baohui
    Jian, Chen
    Zhi, Yao
    Tian Zhihong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (01) : 142 - 150
  • [48] Application expansion and technical trend of foreign countries and special specifications of medium-voltage switchgear
    Sato T.
    Sato, Takashi (takashi.sato.pg@hitachi.com), 2018, Institute of Electrical Engineers of Japan (138) : 801 - 804
  • [49] Overvoltages in secondary circuits of medium-voltage switchgear generated by multiple reignitions of circuit breakers
    Hardt, N
    Koenig, D
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1999, 41 (04) : 510 - 515
  • [50] Temperature rise effects on busbars used in low voltage switchgear
    Halidi, Siti Nur Amalina Mohd
    Rosli, Roslaikha Athirah
    Ghafar, Halim
    Abdullah, Nor Suhada
    Hyie, Koay Mei