The influence of the thickness of an aluminium radiant sheet on the performance of the lightweight floor heating

被引:15
|
作者
Werner-Juszczuk, Anna Justyna [1 ]
机构
[1] Bialystok Tech Univ, Heating Ventilat, Air Conditioning Dept, Wiejska 45E, PL-15351 Bialystok, Poland
来源
关键词
Radiant floor; Aluminium radiant sheet; Dry floor heating system; Lightweight floor heating; Numerical study; SURFACE-TEMPERATURE; NUMERICAL-ANALYSIS; SYSTEM; UNDERFLOOR; BUILDINGS; MODEL; PUMP;
D O I
10.1016/j.jobe.2021.102896
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The aim of this work is to determine the optimal thickness of aluminium radiant sheet in the lightweight floor heating, i.e. the smallest thickness of the aluminium, ensuring high efficiency and thermal comfort. The optimal operational and construction parameters are determined regards to the aluminium thickness. Finding the optimal aluminium thickness is important for economic and ecological reasons: less aluminium thickness, less aluminium consumption and less cost of construction. Numerical calculations were performed with ANSYS Steady-State Thermal Solver (Workbench 19.2) for floor heating with a dry screed, wood-like board and pipes embedded in the layer of tile adhesive. The influence of aluminium thickness changes in the range of 0.1-0.5 mm was analysed for variable water temperature, pipe spacing and constructions. The optimal aluminium radiant sheet thickness is 0.3 mm, 0.1 mm is not recommended. The optimal water temperature is 25-35 degrees C, 45 degrees C is not recommended. Constructions with a dry screed 25 mm thick should not be used. Constructions with pipes in tile adhesive should be used at a water temperature of 25-30 degrees C and an aluminium thickness of 0.3-0.5 mm. Constructions with wood-like board should be used at a water temperature of 25-35 degrees C and an aluminium of 0.3-0.4 mm. Results enable a conscious choice of such constructions and operational parameters of lightweight floor heating that ensure high efficiency, thermal comfort and low investment costs. The work includes the original specification of the lightweight floor heating efficiency depending on the radiant sheet thickness and specifies recommended radiant sheet thicknesses.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] A study on dividing heating area of radiant floor heating system
    Joe, G. S.
    Cho, G. Y.
    Lee, S. W.
    Yeo, M. S.
    Kim, K. W.
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 944 - 951
  • [32] Study on thermal performance of a PCM enhanced hydronic radiant floor heating system
    Larwa, Barbara
    Cesari, Silvia
    Bottarelli, Michele
    Energy, 2021, 225
  • [33] Thermal Performance Analysis of Reinforced Concrete Floor Structure with Radiant Floor Heating System in Apartment Housing
    Jeong, Young-Sun
    Jung, Hae-Kwon
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2015, 2015
  • [34] Experimental Study on Performance of Lightweight Radiant Floor Cooling Combined with Underfloor Ventilation System
    Xia, Xue-ying
    Zhang, Xu
    LOW-CARBON CITY AND NEW-TYPE URBANIZATION, 2015, : 307 - 315
  • [35] Simulation Analysis of Heat Transfer on Low Temperature Hot-water Radiant Floor Heating and Electrical Radiant Floor Heating
    Qi, Hanbing
    He, Fuyun
    Wang, Qiushi
    Li, Dong
    Lin, Lin
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 4234 - +
  • [36] Evaluation of the thermal performance of radiant floor heating system with the influence of unevenly distributed solar radiation based on the theory of discretization
    Zheng, Jiacheng
    Yu, Tao
    Lei, Bo
    Luo, Xiujing
    BUILDING SIMULATION, 2023, 16 (01) : 105 - 120
  • [37] Evaluation of the thermal performance of radiant floor heating system with the influence of unevenly distributed solar radiation based on the theory of discretization
    Jiacheng Zheng
    Tao Yu
    Bo Lei
    Xiujing Luo
    Building Simulation, 2023, 16 : 105 - 120
  • [38] Design of radiant floor heating panel in view of floor surface temperatures
    Shin, Mi Su
    Rhee, Kyu Nam
    Ryu, Seong Ryong
    Yeo, Myoung Souk
    Kim, Kwang Woo
    BUILDING AND ENVIRONMENT, 2015, 92 : 559 - 577
  • [39] Study on the influencing factors of thermal performance of radiant heating floor with the intensive solar irradiation
    Zheng, Jiacheng
    Yu, Tao
    Lei, Bo
    Lv, Ruixin
    APPLIED THERMAL ENGINEERING, 2023, 232
  • [40] Experimental investigation on the performance of solar-thermosyphon embedded radiant floor heating system
    School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China
    Taiyangneng Xuebao, 2008, 6 (637-643):