Testing of long-term behaviour of pre-stressed timber-to-timber composite (TTC) floors

被引:17
|
作者
Riccadonna, Daniele [1 ]
Walsh, Kevin [2 ,3 ]
Schiro, Gianni [1 ]
Piazza, Maurizio [1 ]
Giongo, Ivan [1 ]
机构
[1] Univ Trento, Dept Civil Environm & Mech Engn, Trento, Italy
[2] Univ Notre Dame, Dept Civil & Environm Engn & Earth Sci, Notre Dame, IN 46556 USA
[3] Frost Engn & Consulting, Mishawaka, IN USA
关键词
Long-term behaviour; Timber composite floors; Wood beam cambering; Pre-stressed timber beams; TIME-DEPENDENT BEHAVIOR; BEAMS; WOOD;
D O I
10.1016/j.conbuildmat.2019.117596
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper presents the outcomes of an experimental investigation on the long-term behaviour of timber-to-timber composite (TTC) floors assembled using a cambering-prestressing (CP) procedure previously proposed by the authors. The short-term effectiveness of such technique has been demonstrated in previous literature where it is shown that by exploiting the capability of the screw connectors to apply a compression force on the joining timber members, it is possible to obtain a camber and a prestressed condition without any use of other external devices or propping. To prove the applicability of the aforementioned CP procedure to real life design-scenarios, the long-term efficacy should be investigated. With such aim, four TTC floor specimens of 5.0 m of span and different connection layouts, were loaded in flexure under controlled environmental conditions for a period up to almost 1.5 years. One of the main results from the long-term monitoring of the specimens is that the floors uplift achieved by applying the CP procedure was found to be persistent over time with minimal camber losses. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Simplified procedure for the description from the long-term behaviour of timber-concrete composite structures
    Vereinfachtes Verfahren zur Vorhersage des Langzeitverhaltens von Holz-Beton-Verbundkonstruktionen
    Avak, R., 2005, Ernst and Sohn (82)
  • [22] Testing and long term monitoring of a pre-cast pre-stressed concrete girder bridge
    Johnson, N. R.
    Petroff, S. M.
    Halling, M. W.
    Barr, P. J.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 415 - 422
  • [23] Study of dynamic behaviour of tension of pre-stressed composite cables
    Kaci, S.
    1993, 3
  • [24] Review of Long-Term Performance of Timber-Concrete Composite Beams
    Liu, Peiyang
    Du, Hao
    Chen, Zheng
    Hu, Xiamin
    BIORESOURCES, 2025, 20 (01): : 2374 - 2390
  • [25] Long-term monitoring and field testing of an innovative multistory timber building
    Omenzetter, Piotr
    Morris, Hugh
    Worth, Margaret
    Kohli, Varun
    Uma, S. R.
    NONDESTRUCTIVE CHARACTERIZATION FOR COMPOSITE MATERIALS, AEROSPACE ENGINEERING, CIVIL INFRASTRUCTURE, AND HOMELAND SECURITY 2011, 2011, 7983
  • [26] Experimental Testing and Numerical Simulation of Timber-Concrete Composite Floors in Fire
    Liu, Julie
    Fischer, Erica C.
    Barbosa, Andre R.
    Sinha, Arijit
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (11)
  • [27] Full scale testing of timber-concrete composite floors in an overhanging configuration
    Estevez-Cimadevila, Javier
    Suarez-Riestra, Felix
    Martin-Gutierrez, Emilio
    Otero-Chans, Dolores
    ENGINEERING STRUCTURES, 2023, 291
  • [28] Long-term performance research on reinforced concreted beams with pre-stressed CFRP
    Shang, Shouping
    Zhang, Baojing
    Wu, Jianren
    ISAB-2010 - FIRST INTERNATIONAL SYMPOSIUM ON ARCHIMEDES BRIDGE, 2010, 4 : 341 - 346
  • [29] Application of pre-stressed SMA-based tuned mass damper to a timber floor system
    Huang, Haoyu
    Chang, Wen-Shao
    ENGINEERING STRUCTURES, 2018, 167 : 143 - 150
  • [30] Short-Term, Long-Term, and Vibration Performance of TCC Floors Using Mass-Timber Panels
    Tannert, Thomas
    Gerber, Adam
    Salenikovich, Alexander
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (06)