Skin blood flow differentially affects near-infrared spectroscopy-derived measures of muscle oxygen saturation and blood volume at rest and during dynamic leg exercise

被引:67
|
作者
Tew, Garry A. [2 ]
Ruddock, Alan D. [2 ]
Saxton, John M. [1 ,2 ]
机构
[1] Univ E Anglia, Sch Allied Hlth Profess, Fac Hlth, Norwich NR4 7TU, Norfolk, England
[2] Sheffield Hallam Univ, Ctr Sport & Exercise Sci, Sheffield S10 2BP, S Yorkshire, England
关键词
Near-infrared spectroscopy; Skin blood flow; Exercise; Laser Doppler flowmetry; Muscle oxygen saturation; HUMAN SKELETAL-MUSCLE; ADIPOSE-TISSUE THICKNESS; VASTUS-LATERALIS; SPORTS-MEDICINE; OXIMETERS; HUMANS;
D O I
10.1007/s00421-010-1596-2
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The impact of skin blood flow changes on near-infrared spectroscopy (NIRS)-derived measures of muscle oxygen saturation (SmO2) and blood volume has not been fully established. We measured SmO2 and total hemoglobin concentration ([tHb]) responses of the right vastus lateralis during rest and dynamic knee extension exercise in ten young, healthy males. The protocol was repeated four times: twice without thigh heating for reliability, and twice with different grades of thigh heating for assessing the impact of cutaneous vasodilation on SmO2 and Delta[tHb]. The reliability of our SmO2 and [tHb] measurements was good. Thigh heating at 37 and 42 degrees C caused marked increases in cutaneous vascular conductance (CVC) during rest and exercise (P<0.001 between each condition), and small increases in SmO2 during rest (from 69 +/- 8% to 71 +/- 7% and 73 +/- 6%, respectively; P<0.05 between each condition), but not during exercise (e.g. 1 min exercise: 51 +/- 11% vs. 51 +/- 11% and 52 +/- 11%, respectively; P>0.05 at all time points). In contrast, heating-induced increases in %CVCpeak were accompanied by increases in [tHb] at rest and during exercise and a decrease in Delta[tHb] during exercise (all P<0.05). Our findings suggest that NIRS-derived measures of SmO2 and blood volume are differentially affected by skin blood flow at rest and during exercise. The findings from this study should be considered in NIRS experiments where skin blood flow can change markedly (e.g. high-intensity and/or prolonged exercise).
引用
收藏
页码:1083 / 1089
页数:7
相关论文
共 50 条
  • [41] Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise
    McManus, Chris J.
    Collison, Jay
    Cooper, Chris E.
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (01)
  • [42] Calf muscle blood now and oxygen consumption measured with near-infrared spectroscopy during venous occlusion
    Paunescu, LA
    Casavola, C
    Franceschini, MA
    Fantini, S
    Winter, L
    Kim, J
    Wood, D
    Gratton, E
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE III, PROCEEDINGS OF, 1999, 3597 : 317 - 323
  • [43] Effects of Different Hemoglobin Levels on Near-Infrared Spectroscopy-Derived Cerebral Oxygen Saturation in Elderly Patients Undergoing Noncardiac Surgery
    Delis, Achilles
    Bautz, Derek
    Ehrentraut, Heidi
    Doll, Karin
    Randau, Thomas M.
    Strauss, Andreas C.
    Habicht, Ivana
    Gueresir, Erdem
    Bogatsch, Holger
    Kranke, Peter
    Wittmann, Maria
    Meybohm, Patrick
    Velten, Markus
    TRANSFUSION MEDICINE AND HEMOTHERAPY, 2023, 50 (04) : 270 - 276
  • [44] New instrument to measure oxygen saturation and total hemoglobin volume in local skin by near-infrared spectroscopy
    Nagashima, Y
    Komeda, N
    Yada, Y
    Sakai, A
    Nose, H
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON BIOELECTROMAGNETISM, 1998, : 53 - 54
  • [45] Comparison of femoral blood gases and muscle near-infrared spectroscopy at exercise onset in humans
    MacDonald, MJ
    Tarnopolsky, MA
    Green, HJ
    Hughson, RL
    JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (02) : 687 - 693
  • [46] DETERMINATION OF OXYGEN-CONSUMPTION IN MUSCLE DURING EXERCISE USING NEAR-INFRARED SPECTROSCOPY
    COLIER, WNJM
    MEEUWSEN, IBAE
    DEGENS, H
    OESEBURG, B
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 : 151 - 155
  • [47] The effects of dichloroacetate on leg blood flow and muscle metabolism at rest and during exercise in humans.
    Gibala, MJ
    Rådegran, G
    Saltin, B
    FASEB JOURNAL, 1999, 13 (05): : A1051 - A1051
  • [48] Near infrared spectroscopy measures of tissue oxygenation are influenced by increases in skin blood flow
    Davis, SL
    Fadel, PJ
    Cui, J
    Thomas, GD
    Crandall, CG
    FASEB JOURNAL, 2005, 19 (05): : A1219 - A1219
  • [49] The validity and reliability of continuous-wave near-infrared spectroscopy for the assessment of leg blood volume during an orthostatic challenge
    Stone, Keeron J.
    Fryer, Simon M.
    Ryan, Terence
    Stoner, Lee
    ATHEROSCLEROSIS, 2016, 251 : 234 - 239
  • [50] A mesenteric traction syndrome affects near-infrared spectroscopy evaluated cerebral oxygenation because skin blood flow increases
    Olesen, Niels D.
    Sorensen, Henrik
    Ambrus, Rikard
    Svendsen, Lars B.
    Lund, Anton
    Secher, Niels H.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (02) : 261 - 268