A novel gold nanostars-based fluorescent aptasensor for aflatoxin B1 detection

被引:38
|
作者
Wei, Min [1 ]
Zhao, Fei [1 ]
Xie, Yanli [1 ]
机构
[1] Henan Univ Technol, Henan Key Lab Cereal & Oil Food Safety Inspect &, Coll Food Sci & Technol, Zhengzhou 450001, Peoples R China
关键词
AuNSs; Fluorescence quenching; Aptamer; Aflatoxin B1; ELECTROCHEMICAL APTASENSOR; ULTRASENSITIVE DETECTION; SIGNAL AMPLIFICATION; APTAMER; B-1; NANOPARTICLES; IMMUNOASSAY; OCHRATOXIN; PLATFORM; PEANUT;
D O I
10.1016/j.talanta.2019.120599
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a simple and sensitive fluorescent aptasensor for aflatoxin B1 (AFB(1)) detection was proposed using gold nanostars (AuNSs) as a novel fluorescence quenching material. Carboxyfluorescein-labeled complementary DNA with hairpin structure (FAM-labeled HP) was designed to hybridize with AFB(1) aptamer to form double-stranded DNA, resulting in the opening of hairpin structure. When double-stranded DNA was modified on AuNSs surface, FAM was far from AuNSs and produced a strong fluorescence intensity. The introduction of AFB(1) in the system led to the specific interaction of AFB(1) and aptamer, and changed the conformation of aptamer, inducing the release of aptamer from double-stranded DNA and the restoration of hairpin structure. Fluorescence quenching occurred when FAM was close to AuNSs, and the fluorescence intensity decreased. In the presence of 5 ng/mL AFB(1), Delta F/F-0 of the AuNSs/FAM-labeled HP/Apt was similar to 44.2%, higher than that of the AuNPs/FAM-labeled HP/Apt, indicating the better quenching effect of AuNSs. The change of fluorescence intensity linearly increased by adding AFB(1) in the concentration range of 0.1 ng/mL-10 ng/mL, with the LOD of 21.3 pg/mL. The proposed aptasensor exhibited good selectivity in the presence of other toxins at 10-fold concentration of AFB(1), and showed satisfactory recovery in the range of 92%-112% toward AFB(1) detection in spiked corn flour sample.
引用
下载
收藏
页数:7
相关论文
共 50 条
  • [21] Detection of aflatoxin B1with a new label-free fluorescent aptasensor based on exonuclease I and SYBR Gold
    Guo, Zhijun
    Lv, Lei
    Cui, Chengbi
    Wang, Yan
    Ji, Shuang
    Fang, Jiaqi
    Yuan, Ming
    Yu, Hansong
    ANALYTICAL METHODS, 2020, 12 (22) : 2928 - 2933
  • [22] Electrochemical Aptasensor Based on Polycarboxylic Macrocycle Modified with Neutral Red for Aflatoxin B1 Detection
    Evtugyn, Gennady
    Porfireva, Anna
    Stepanova, Veronika
    Sitdikov, Rusal
    Stoikov, Ivan
    Nikolelis, Dimitrios
    Hianik, Tibor
    ELECTROANALYSIS, 2014, 26 (10) : 2100 - 2109
  • [23] Electrochemical aptasensor based on polycarboxylic macrocycle modified with neutral red for aflatoxin B1 detection
    Hianik, Tibor (Tibor.Hianik@fmph.uniba.sk), 1600, Wiley-VCH Verlag (26):
  • [24] A dual-signal aptasensor based on cascade amplification for ultrasensitive detection of aflatoxin B1
    Zhu, Fang
    Zhang, Hu
    Wu, Ruoxi
    Lu, Yanyan
    Wang, Jin
    Ravikumar, A.
    Selvan, G. Tamil
    Zhu, Nuanfei
    Zhang, Zhen
    Tang, Jun
    BIOSENSORS & BIOELECTRONICS, 2024, 250
  • [25] Rapid Visual Detection of Aflatoxin B1 by Label-Free Aptasensor Using Unmodified Gold Nanoparticles
    Luan, Yunxia
    Chen, Zhengbo
    Xie, Gang
    Chen, Jiayi
    Lu, Anxiang
    Li, Cheng
    Fu, Hailong
    Ma, Zhihong
    Wang, Jihua
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2015, 15 (02) : 1357 - 1361
  • [26] A new amplified π-shape electrochemical aptasensor for ultrasensitive detection of aflatoxin B1
    Abnous, Khalil
    Danesh, Noor Mohammad
    Alibolandi, Mona
    Ramezani, Mohammad
    Emrani, Ahmad Sarreshtehdar
    Zolfaghari, Reza
    Taghdisi, Seyed Mohammad
    BIOSENSORS & BIOELECTRONICS, 2017, 94 : 374 - 379
  • [27] MnO2 nanoflowers based colorimetric and fluorescent dual-mode aptasensor for sensitive detection of aflatoxin B1 in milk
    Li, Shuofeng
    Wang, Fangfang
    Zhao, Bin
    Wang, Chun
    Wang, Zhi
    Wu, Qiuhua
    ANALYTICA CHIMICA ACTA, 2023, 1279
  • [28] Recent progress in optical and electrochemical aptasensor technologies for detection of aflatoxin B1
    Guo, Xiaodong
    Wang, Mengzhi
    CRITICAL REVIEWS IN FOOD SCIENCE AND NUTRITION, 2023, 64 (33) : 13093 - 13111
  • [29] A Rapid Label-Free Fluorescent Aptasensor PicoGreen-Based Strategy for Aflatoxin B1 Detection in Traditional Chinese Medicines
    Zhang, Cheng
    Dou, Xiaowen
    Zhang, Lei
    Sun, Meifeng
    Zhao, Ming
    OuYang, Zhen
    Kong, Dandan
    Antonio, F. Logrieco
    Yang, Meihua
    TOXINS, 2018, 10 (03):
  • [30] A label-free fluorescent aptasensor for the detection of Aflatoxin B1 in food samples using AIEgens and graphene oxide
    Jia, Yongmei
    Wu, Feng
    Liu, Peilian
    Zhou, Guohua
    Yu, Biao
    Lou, Xiaoding
    Xia, Fan
    TALANTA, 2019, 198 : 71 - 77