Ultrasound shear-wave elastography applicability in estimation of post-mortem time

被引:2
|
作者
Mosadegh, Mohsen [1 ]
Khazaei, Mehdi [1 ]
Abdollahpour, Zohreh D. [2 ]
Alahyari, Sam [3 ]
Moharamzad, Yashar [1 ]
Emamhadi, Mohammadali [4 ]
Aram, Samira [5 ]
Abolbaghaei, Mojtaba [5 ]
Taheri, Morteza Sanei [1 ]
机构
[1] Shahid Beheshti Univ Med Sci, Radiol Dept, Tehran, Iran
[2] TANASA TEB NOVIN Co, Clin Applicat Dept, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Fac Med, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Forens Med Dept, Tehran, Iran
[5] Legal Med Org, Legal Med Res Ctr, Tehran, Iran
关键词
Ultrasound; tissue stiffness; rigor mortis; post-mortem interval; forensic science; DIAGNOSIS;
D O I
10.1177/1742271X211035810
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Post-mortem rigidity of the tissues is one of the basic principles in forensic medicine to estimate the time of death. Qualitative methods to determine the stiffness of the corpse may have some limitations. Methods that provide quantitative values may be useful. We intended to evaluate the applicability of ultrasound shear-wave elastography of the tissues to estimate the post-mortem interval (PMI). Methods: For 80 corpses, shear-wave elastography of the liver, sartorius muscle, testis, thyroid and parotid was performed before autopsy. Based on the forensic reports as the reference method to define postmortem interval, the corpses were divided into four groups: group 0 (PMI <24 hours), group 1 (PMI >= 24 hours and <48 hours), group 2 (PMI >= 48 hours and <72 hours), and group 3 (PMI >= 72 hours). There were 24, 38, 13, and 5 corpses, respectively, in groups 0, 1, 2, and 3. Results: A significant rise in the elasticity values in comparison to elasticity of normal tissues in live adults was seen very early in the post-mortem period. Between-group comparisons showed that a significant difference in the liver elasticity was present among the groups. The mean (SD) liver elasticity was 10.29 (+/- 0.83) in group 0, 14.98 (+/- 1.56) in group 1, 12.49 (+/- 1.09) in group 2, and 15.64 (+/- 1.68) kilopascals (kPa) in group 3 (P 0.035). Nevertheless, elasticity measurements in other tissues were not helpful in distinguishing post-mortem interval groups. Conclusion: It is possible to use liver quantitative shear-wave elastography to estimate the time of death.
引用
收藏
页码:134 / 140
页数:7
相关论文
共 50 条
  • [21] Agreement and accuracy of shear-wave techniques (point shear-wave elastography and 2D-shear-wave elastography) using transient elastography as reference
    Fernandes, Flavia
    Piedade, Juliana
    Freitas, Gabriela
    Area, Philippe
    Santos, Ricardo
    Grinsztejn, Beatriz
    Veloso, Valdilea
    Pereira, Gustavo
    Perazzo, Hugo
    [J]. EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2022, 34 (08) : 873 - 881
  • [22] Reliability and applicability of two-dimensional shear-wave elastography for the evaluation of liver stiffness
    Varbobitis, Ioannis C.
    Siakavellas, Spyros I.
    Koutsounas, Ioannis S.
    Karagiannakis, Dimitrios S.
    Ioannidou, Panagiota
    Papageorgiou, Maria-Vasiliki
    Pavlopoulou, Ioanna D.
    Schizas, Dimitrios
    Bamias, Giorgos
    Vlachogiannakos, Ioannis
    Ladas, Spyros D.
    Papatheodoridis, George V.
    [J]. EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2016, 28 (10) : 1204 - 1209
  • [23] The evaluation of retrobulbar fat tissue in Graves’ orbitopathy with shear-wave ultrasound elastography
    Irfan Botan Gunes
    Hakan Yilmaz
    Eda Demir Onal
    [J]. International Ophthalmology, 44
  • [24] Shear-wave versus strain elastography in endoscopic ultrasound for the diagnosis of chronic pancreatitis
    Yamashita, Yasunobu
    Yamazaki, Hirofumi
    Shimokawa, Toshio
    Kawaji, Yuki
    Tamumra, Takashi
    Hatamaru, Keiichi
    Itonaga, Masahiro
    Ashida, Reiko
    Kitano, Masayuki
    [J]. PANCREATOLOGY, 2023, 23 (01) : 35 - 41
  • [25] Shear-wave ultrasound elastography of the liver in normal-weight and obese children
    Bailey, Smita Sane
    Youssfi, Mostafa
    Patel, Mittun
    Hu, Houchun H.
    Shaibi, Gabriel Q.
    Towbin, Richard B.
    [J]. ACTA RADIOLOGICA, 2017, 58 (12) : 1511 - 1518
  • [26] The evaluation of retrobulbar fat tissue in Graves' orbitopathy with shear-wave ultrasound elastography
    Gunes, Irfan Botan
    Yilmaz, Hakan
    Onal, Eda Demir
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [27] Estimation of the time since death in the early post-mortem period
    Henssge, C
    Madea, B
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2004, 144 (2-3) : 167 - 175
  • [28] Quantitative shear-wave optical coherence elastography with a programmable phased array ultrasound as the wave source
    Song, Shaozhen
    Le, Nhan Minh
    Huang, Zhihong
    Shen, Tueng
    Wang, Ruikang K.
    [J]. OPTICS LETTERS, 2015, 40 (21) : 5007 - 5010
  • [29] Shear-Wave Elastography of Segmental Infarction of the Testis
    Kantarci, Fatih
    Olgun, Deniz Cebi
    Mihmanli, Ismail
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (06) : 820 - 822
  • [30] Association of shear-wave elastography with clinical outcomes post-liver transplantation
    Boeken, Tom
    Lucidarme, Olivier
    Mbarki, Elsa
    Scatton, Olivier
    Savier, Eric
    Wagner, Mathilde
    [J]. CLINICS AND RESEARCH IN HEPATOLOGY AND GASTROENTEROLOGY, 2021, 45 (05)