Simple and reliable extraction and a validated high performance liquid chromatographic assay for quantification of amoxicillin from plasma

被引:11
|
作者
Purohit, Trusha J. [1 ]
Wu, Zimei [1 ]
Hanning, Sara M. [1 ]
机构
[1] Univ Auckland, Sch Pharm, 85 Pk Rd, Auckland 1010, New Zealand
关键词
Amoxicillin; Stability and solubility; Protein precipitation; Quantitative analysis; Plasma samples; Rabbit pharmacokinetics; BETA-LACTAM ANTIBIOTICS; SOLID-PHASE EXTRACTION; SAMPLE PREPARATION; SENSITIVE ASSAY; SERUM; HPLC; DRUGS; FLUID;
D O I
10.1016/j.chroma.2019.460611
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study presents the development of an efficient extraction protocol for amoxicillin from plasma with improved solubility and stability using pH control. Solubility and stability of amoxicillin in commonly used extraction solvents were determined using a newly developed stability-indicating high-performance liquid chromatography (HPLC) method. Following this, protein precipitation (PP) mediated sample purification protocol was developed and validated along with the HPLC method for the extracted amoxicillin from rabbit plasma. The protocol was applied in a pharmacokinetic study in rabbits. A five-fold increase in solubility and two-fold increase in stability of amoxicillin was found by addition of acetate buffer (0.1 M, pH 5.0) in acetonitrile. PP mediated extraction protocol containing acetate buffer-acetonitrile (1:18 v/v) resulted in an extraction recovery of >80% for all the samples. The HPLC assay following extraction was found linear (R-2 >0.9999) over the range of 0.2-20 mu g/mL with a lower limit of quantification of 0.2 mu g/mL. The accuracy of the quality control samples was found between 97-115% and the relative standard deviation (RSD) was found to be below 6% for all samples. The samples were stable in the mobile phase (pH 5.0) for 72h post-extraction. Amoxicillin-spiked plasma samples were found stable for up to three freeze-and-thaw cycles but, nearly 50% samples had degraded following storage for two months at -20 degrees C. Pharmacokinetic analysis indicated a half-life of amoxicillin of nearly 1 h following intravenous injection in rabbits, which is similar to that in humans. Thus, a simple and repeatable, extraction protocol was developed using pH control for quantification of amoxicillin from plasma based on its physicochemical properties. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Rapid high-performance liquid chromatographic assay for salicylic acid in plasma without solvent extraction
    Coudray, C
    Mangournet, C
    Bouhadjeb, S
    Faure, H
    Favier, A
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1996, 34 (04) : 166 - 173
  • [22] High-performance liquid chromatographic assay of formycin A in plasma after solid-phase extraction
    Misztal, G
    Paw, B
    Skierski, JS
    Jagiello-Wójtowicz, E
    JOURNAL OF CHROMATOGRAPHY B, 1999, 731 (02): : 383 - 387
  • [23] High-performance liquid chromatographic assay of dilazep in plasma after solid-phase extraction
    Gumieniczek, A
    Przyborowski, L
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (07) : 997 - 1000
  • [24] Quantification of Pyrazinamide in Human Plasma by Validated High Performance Liquid Chromatography Method
    Arshad, Waleed
    Ahmad, Naseem Saud
    Khan, Abdul Muqeet
    Imran, Iram
    Qura-Tul-Ain
    Akhtar, Mahreen
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (10): : 2896 - 2899
  • [25] A simple high-performance liquid chromatographic assay for concurrent quantification of lumefantrine and efavirenz in human plasma from malaria-HIV co-infected individuals
    Adegbola, Adebanjo J.
    Ogboye, Ruth M.
    Soyinka, Julius O.
    Bolaji, Oluseye O.
    FUTURE JOURNAL OF PHARMACEUTICAL SCIENCES, 2023, 9 (01)
  • [26] High-performance liquid chromatographic assay of amiodarone in rat plasma
    Jun, AS
    Brocks, DR
    JOURNAL OF PHARMACY AND PHARMACEUTICAL SCIENCES, 2001, 4 (03): : 263 - 268
  • [28] High-performance liquid chromatographic assay for the determination of haloperidol in plasma
    ElSayed, YM
    Khidr, SH
    Niazy, EM
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (01) : 125 - 134
  • [29] Sensitive high performance liquid chromatographic assay for nitazoxanide metabolite in plasma
    Ruiz-Olmedo, M. I.
    Gallegos-Perez, J. L.
    Calderon-Gonzalez, K. G.
    Franco-Perez, J.
    Jung-Cook, H.
    PHARMAZIE, 2009, 64 (07): : 419 - 422
  • [30] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF BENZALKONIUM IN PLASMA
    BLEAU, G
    DESAULNIERS, M
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 487 (01): : 221 - 227