From a lab test to industrial application: scale-up of Fenton process for real olive mill wastewater treatment

被引:27
|
作者
Amaral-Silva, Nuno [1 ,2 ,3 ]
Martins, Rui C. [1 ,2 ]
Nunes, Paulo [3 ]
Castro-Silva, Sergio [3 ]
Quinta-Ferreira, Rosa M. [1 ,2 ]
机构
[1] Univ Coimbra, Fac Sci & Technol, Dept Chem Engn, CIEPQPF, P-3030790 Coimbra, Portugal
[2] Univ Coimbra, Fac Sci & Technol, Dept Chem Engn, GERST, P-3030790 Coimbra, Portugal
[3] Ctr Empresarial & Tecnol, ADVENTECH Adv Environm Technol, Rua Fundoes 151, P-3700121 Sao Joao Da Madeira, Portugal
关键词
ferric coagulation; Fenton based treatment; olive mill wastewater; integrated biological treatment; economical assessment; real scale treatment unit; ADVANCED OXIDATION PROCESSES; COAGULATION-FLOCCULATION; ANAEROBIC-DIGESTION; HYDROGEN-PEROXIDE; PILOT-SCALE; WASTEWATERS; EXTRACTION; EFFLUENTS; PRETREATMENT; DEGRADATION;
D O I
10.1002/jctb.5128
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
BACKGROUND: This study evaluates the integration of ferric coagulation, Fenton oxidation (both at lab and industrial scale) and activated sludge (at lab scale) for the treatment of olive mill wastewater. RESULTS: Initially, an iron based coagulation at the raw pH of olive mill effluent was performed, leading to 38% COD abatement at bench scale. This procedure also provided some dissolved iron that can be used as catalyst in the following Fenton's peroxidation step. At lab scale Fenton's process accomplished COD removal of 75%. Moreover, some biodegradability enhancement was achieved with this procedure with initial BOD5/COD average = 0.03 increasing to BOD5/COD average = 0.37 after the process. This integrated treatment was then applied at industrial scale and, after further optimization, coagulation and Fenton's processes were able to remove 43% and 62% of COD, respectively. CONCLUSION: Based on the interesting results gathered at lab-scale, it was possible to optimize an industrial WWTP (wastewater treatment plant). Ferric coagulation followed by Fenton's peroxidation was implemented with efficiency up to 90% and final COD of 200 mgO(2) L-1. The resulting wastewater can be discharged into municipal sewage or can be recycled for reutilization after an in situ biological treatment. (C) 2016 Society of Chemical Industry
引用
收藏
页码:1336 / 1344
页数:9
相关论文
共 50 条
  • [41] Granulation strategies applied to industrial wastewater treatment: from lab to full-scale
    Caluwe, M.
    Goossens, K.
    Suazo, K. Seguel
    Tsertou, E.
    Dries, J.
    WATER SCIENCE AND TECHNOLOGY, 2022, 85 (09) : 2761 - 2771
  • [42] Electrochemical removal of tetrahydrofuran from industrial wastewaters: anode selection and process scale-up
    Urtiaga, Ane
    Gomez, Pedro
    Arruti, Axel
    Ortiz, Inmaculada
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2014, 89 (08) : 1243 - 1250
  • [43] Solar Fenton: from pilot to industrial scale application for polishing winery wastewater pretreated by MBR
    Ioannou, Lida
    Michael, Costas
    Kyriakou, Stathis
    Fatta-Kassinos, Despo
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2014, 89 (07) : 1067 - 1076
  • [44] Self-Activated Ni Cathode for Electrocatalytic Nitrate Reduction to Ammonia: From Fundamentals to Scale-Up for Treatment of Industrial Wastewater
    Zheng, Wenxiao
    Zhu, Liuyi
    Yan, Zhang
    Lin, Zichao
    Lei, Zhenchao
    Zhang, Yifan
    Xu, Haolin
    Dang, Zhi
    Wei, Chaohai
    Feng, Chunhua
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2021, 55 (19) : 13231 - 13243
  • [45] Plasma-based water treatment: Targeted application and guidelines for process scale-up
    Mededovic, Selma
    Bellona, Christopher
    Holsen, Thomas
    Stratton, Gunnar
    Dai, Fei
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [46] Scale up of Semisolid Dosage Forms Manufacturing Based on Process Understanding: from Lab to Industrial Scale
    van Heugten, Anton J. P.
    Vromans, Herman
    AAPS PHARMSCITECH, 2018, 19 (05): : 2330 - 2334
  • [47] Scale up of Semisolid Dosage Forms Manufacturing Based on Process Understanding: from Lab to Industrial Scale
    Anton J. P. van Heugten
    Herman Vromans
    AAPS PharmSciTech, 2018, 19 : 2330 - 2334
  • [48] From lab-scale to pilot-scale treatment of real wastewater from the production of rayon fiber
    Kuchtova, Gabriela
    Herink, Petr
    Herink, Tomas
    Chylkova, Jaromira
    Mikulasek, Petr
    Dusek, Libor
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 171 : 834 - 846
  • [49] Biocompounds recovery from olive mill wastewater by liquid-liquid extraction and integration with Fenton’s process for water reuse
    Daniela Martins
    Rui C. Martins
    Mara E. M. Braga
    Environmental Science and Pollution Research, 2021, 28 : 29521 - 29534
  • [50] Biocompounds recovery from olive mill wastewater by liquid-liquid extraction and integration with Fenton's process for water reuse
    Martins, Daniela
    Martins, Rui C.
    Braga, Mara E. M.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (23) : 29521 - 29534