From a lab test to industrial application: scale-up of Fenton process for real olive mill wastewater treatment

被引:27
|
作者
Amaral-Silva, Nuno [1 ,2 ,3 ]
Martins, Rui C. [1 ,2 ]
Nunes, Paulo [3 ]
Castro-Silva, Sergio [3 ]
Quinta-Ferreira, Rosa M. [1 ,2 ]
机构
[1] Univ Coimbra, Fac Sci & Technol, Dept Chem Engn, CIEPQPF, P-3030790 Coimbra, Portugal
[2] Univ Coimbra, Fac Sci & Technol, Dept Chem Engn, GERST, P-3030790 Coimbra, Portugal
[3] Ctr Empresarial & Tecnol, ADVENTECH Adv Environm Technol, Rua Fundoes 151, P-3700121 Sao Joao Da Madeira, Portugal
关键词
ferric coagulation; Fenton based treatment; olive mill wastewater; integrated biological treatment; economical assessment; real scale treatment unit; ADVANCED OXIDATION PROCESSES; COAGULATION-FLOCCULATION; ANAEROBIC-DIGESTION; HYDROGEN-PEROXIDE; PILOT-SCALE; WASTEWATERS; EXTRACTION; EFFLUENTS; PRETREATMENT; DEGRADATION;
D O I
10.1002/jctb.5128
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
BACKGROUND: This study evaluates the integration of ferric coagulation, Fenton oxidation (both at lab and industrial scale) and activated sludge (at lab scale) for the treatment of olive mill wastewater. RESULTS: Initially, an iron based coagulation at the raw pH of olive mill effluent was performed, leading to 38% COD abatement at bench scale. This procedure also provided some dissolved iron that can be used as catalyst in the following Fenton's peroxidation step. At lab scale Fenton's process accomplished COD removal of 75%. Moreover, some biodegradability enhancement was achieved with this procedure with initial BOD5/COD average = 0.03 increasing to BOD5/COD average = 0.37 after the process. This integrated treatment was then applied at industrial scale and, after further optimization, coagulation and Fenton's processes were able to remove 43% and 62% of COD, respectively. CONCLUSION: Based on the interesting results gathered at lab-scale, it was possible to optimize an industrial WWTP (wastewater treatment plant). Ferric coagulation followed by Fenton's peroxidation was implemented with efficiency up to 90% and final COD of 200 mgO(2) L-1. The resulting wastewater can be discharged into municipal sewage or can be recycled for reutilization after an in situ biological treatment. (C) 2016 Society of Chemical Industry
引用
收藏
页码:1336 / 1344
页数:9
相关论文
共 50 条
  • [1] Scale-up Fenton process: study and optimization in piggery wastewater treatment
    Zarate-Guzman, Ana, I
    Warren-Vega, Walter M.
    Romero-Cano, Luis A.
    Cardenas-Mijangos, Jesus
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2021, 96 (02) : 341 - 348
  • [2] TREATMENT OF OLIVE MILL WASTEWATER BY COMBINED PROCESS OF COAGULATION, FENTON OXIDATION AND ADSORPTION PROCESS
    Kilic, Melike Yalili
    FRESENIUS ENVIRONMENTAL BULLETIN, 2021, 30 (03): : 2397 - 2403
  • [3] Treatment of olive-mill wastewater from a two-phase process by chemical oxidation on an industrial scale
    Nieto, L. M.
    Hodaifa, G.
    Vives, S. R.
    Casares, J. A. G.
    Driss, S. B.
    Grueso, R.
    WATER SCIENCE AND TECHNOLOGY, 2009, 59 (10) : 2017 - 2027
  • [4] Application of Fenton Process in Industrial Wastewater Treatment Plant
    Liu, Fang
    Li, Jun
    2018 2ND INTERNATIONAL CONFERENCE ON ENVIRONMENTAL AND ENERGY ENGINEERING (IC3E 2018), 2018, 146
  • [5] Polyphenolic Fraction from Olive Mill Wastewater: Scale-Up and in Vitro Studies for Ophthalmic Nutraceutical Applications
    Di Mauro, Maria Domenica
    Fava, Giovanni
    Spampinato, Marcella
    Aleo, Danilo
    Melilli, Barbara
    Saita, Maria Grazia
    Centonze, Giovanni
    Maggiore, Riccardo
    D'Antona, Nicola
    ANTIOXIDANTS, 2019, 8 (10)
  • [6] Getting good scale-up performance - Transferring the scale-up process from the lab to the plant
    Tatterson, G
    CHEMICAL PROCESSING, 2000, 63 (10): : 18 - 18
  • [7] Fenton oxidation of primary municipal wastewater treatment plant sludge: Process modelling and reactor scale-up
    Vilardi, Giorgio
    Bavasso, Irene
    Scarsella, Marco
    Verdone, Nicola
    Di Palma, Luca
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2020, 140 : 46 - 59
  • [8] Pilot scale hybrid process for olive mill wastewater treatment and reuse
    Khoufi, Sonia
    Aloui, Fathi
    Sayadi, Sami
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2009, 48 (02) : 643 - 650
  • [9] TREATMENT OF PRETREATED OLIVE MILL WASTEWATER USING FENTON PROCESS IN THE PRESENCE OF UV AND US
    Kaykioglu, Gul
    Balci, Cemre Nur
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2022, 21 (11): : 1803 - 1813
  • [10] Treatment of olive mill wastewater by a combined process: Fenton's reagent and chemical coagulation
    Lucas, Marco S.
    Peres, Jose A.
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2009, 44 (02): : 198 - 205