Operational behavior characteristics and energy saving potential of vertical closed loop ground source heat pump system combined with storage tank in an office building

被引:21
|
作者
Kim, Min Ji [1 ]
Seo, Byeong Mo [2 ]
Lee, Jong Man [1 ]
Choi, Jong Min [3 ]
Lee, Kwang Ho [4 ]
机构
[1] Hanbat Natl Univ, Grad Sch, San 16-1, Daejeon 305719, South Korea
[2] North Carolina State Univ, Coll Design, 50 Pullen Rd,Campus Box 7701, Raleigh, NC 27695 USA
[3] Hanbat Natl Univ, Dept Mech Engn, San 16-1, Daejeon 305719, South Korea
[4] Hanbat Natl Univ, Dept Architectural Engn, San 16-1, Daejeon 305719, South Korea
关键词
Vertical Closed Loop Ground Source Heat; Pump (VGSHP); Part Load Ratio (PLR); Energyplus; Heat storage tank; Coefficient of Performance (COP); Performance curve;
D O I
10.1016/j.enbuild.2018.09.025
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A ground source heat pump (GSHP) system utilizes a relatively stable underground temperature to achieve energy-saving for heating and cooling in buildings. Among various types of GSHP systems, Vertical Closed Loop Ground Source Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, in order to improve the system performance of a VGSHP, a VGSHP system coupled with heat storage tank was evaluated. For this purpose, the detailed analysis on the operational behavior of heat storage tank and the variations of heat pump energy performance due to the connection with heat storage tank was performed, and characteristics of heat pump part load ratios (PLRs) and the corresponding energy requirements, compared to chiller and boiler based conventional system, were analyzed in detail, using dynamic energy simulation after comprehensive validation process of heat pump performance curves. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 20% for cooling and about 77% for heating compared to the conventional air conditioning system, and an energy saving effect of about 2% for cooling and about 15% for heating compared to the VGSHP system without heat storage tank, mainly due to the fact that the operational pattern of heat pump such as PLR and COP characteristics was changed by the operation of heat storage tank. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:239 / 252
页数:14
相关论文
共 50 条
  • [21] Study on Ground Source Heat Pump System of Combined Office and Residential Building in Hot Summer and Warm Winter Region
    Hu, Yingning
    Liu, Yazhao
    Lin, Jun
    Wang, Yan
    THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 564 - 570
  • [22] Optimisation for interconnected energy hub system with combined ground source heat pump and borehole thermal storage
    Huo, Da
    Wei, Wei
    Le Blond, Simon
    FRONTIERS IN ENERGY, 2018, 12 (04) : 529 - 539
  • [23] Optimisation for interconnected energy hub system with combined ground source heat pump and borehole thermal storage
    Da Huo
    Wei Wei
    Simon Le Blond
    Frontiers in Energy, 2018, 12 : 529 - 539
  • [24] Operating characteristics of energy storage ground source heat pump cooling system in plant factory in summer
    Shi H.
    Tian Q.
    Meng X.
    Ren Y.
    Ouyang S.
    Zhang Z.
    An W.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2019, 35 (21): : 202 - 209
  • [25] A Case Study of a Ground-Source Heat Pump System in an East China Office Building
    Li, Zhengrong
    Zhao, Mingming
    Yu, Sheng
    Li, Haozhu
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1586 - 1592
  • [26] Combined solar and ground source heat pump heating system with a latent heat storage tank as a sustainable system to replace an oilfield hot water station
    Li, Dong
    Wang, Zezhao
    Wu, Yangyang
    Yu, Nansong
    Zhao, Xuefeng
    Meng, Lan
    Arici, Muslum
    ENERGY, 2024, 307
  • [27] A study on operational strategy of ground -source heat pump system based on variation of building load
    Tian, X.
    Yang, M. J.
    Zhao, J. W.
    He, S. M.
    Zhao, Jun
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 1508 - 1513
  • [28] Dynamic operational optimization of air source heat pump heating system with consideration of energy saving
    Ding, Qiang
    Xing, Changxin
    Jiang, Aipeng
    Cheng, Wen
    Zhou, Dahan
    Huagong Xuebao/CIESC Journal, 2015, 66 (06): : 2166 - 2173
  • [29] Dynamic Operational Optimization of Air Source Heat Pump Heating System with the Consideration of Energy Saving
    Xing, Changxin
    Ding, Qiang
    Jiang, Aipeng
    Cheng, Wen
    Zhou, Dahan
    IFAC PAPERSONLINE, 2015, 48 (08): : 740 - 745
  • [30] Air Source Heat Pump Energy Storage Heating System for Smart Building
    Chen Xing-chi
    Zhang Xiao-jing
    Zhao Hai
    PROCEEDINGS OF THE 28TH CHINESE CONTROL AND DECISION CONFERENCE (2016 CCDC), 2016, : 3635 - 3639