Operational behavior characteristics and energy saving potential of vertical closed loop ground source heat pump system combined with storage tank in an office building

被引:21
|
作者
Kim, Min Ji [1 ]
Seo, Byeong Mo [2 ]
Lee, Jong Man [1 ]
Choi, Jong Min [3 ]
Lee, Kwang Ho [4 ]
机构
[1] Hanbat Natl Univ, Grad Sch, San 16-1, Daejeon 305719, South Korea
[2] North Carolina State Univ, Coll Design, 50 Pullen Rd,Campus Box 7701, Raleigh, NC 27695 USA
[3] Hanbat Natl Univ, Dept Mech Engn, San 16-1, Daejeon 305719, South Korea
[4] Hanbat Natl Univ, Dept Architectural Engn, San 16-1, Daejeon 305719, South Korea
关键词
Vertical Closed Loop Ground Source Heat; Pump (VGSHP); Part Load Ratio (PLR); Energyplus; Heat storage tank; Coefficient of Performance (COP); Performance curve;
D O I
10.1016/j.enbuild.2018.09.025
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A ground source heat pump (GSHP) system utilizes a relatively stable underground temperature to achieve energy-saving for heating and cooling in buildings. Among various types of GSHP systems, Vertical Closed Loop Ground Source Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, in order to improve the system performance of a VGSHP, a VGSHP system coupled with heat storage tank was evaluated. For this purpose, the detailed analysis on the operational behavior of heat storage tank and the variations of heat pump energy performance due to the connection with heat storage tank was performed, and characteristics of heat pump part load ratios (PLRs) and the corresponding energy requirements, compared to chiller and boiler based conventional system, were analyzed in detail, using dynamic energy simulation after comprehensive validation process of heat pump performance curves. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 20% for cooling and about 77% for heating compared to the conventional air conditioning system, and an energy saving effect of about 2% for cooling and about 15% for heating compared to the VGSHP system without heat storage tank, mainly due to the fact that the operational pattern of heat pump such as PLR and COP characteristics was changed by the operation of heat storage tank. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:239 / 252
页数:14
相关论文
共 50 条
  • [1] An office building energy-saving design of ground source heat pump system
    Yu, Wei
    Zhu, Chunying
    Gao, Menghui
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 : 3093 - 3096
  • [2] Experimental study of a closed loop vertical ground source heat pump system
    Hepbasli, A
    Akdemir, O
    Hancioglu, E
    ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (04) : 527 - 548
  • [3] The energy-saving study of ground source heat pump system in public building
    Zhou, Zhihua
    Li, Yonggang
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 808 - 811
  • [4] Efficiency Investigation and Energy Saving of Vertical Ground Source Heat Pump
    Desmedt, Johan
    Van Bael, Johan
    STROJARSTVO, 2010, 52 (04): : 405 - 409
  • [5] Influence of the water tank size and air source heat pump size on the energy saving potential of the energy storage heating system
    Lyu, Weihua
    Wang, Zhichao
    Li, Xiaofeng
    Deng, Gaofeng
    Xu, Zhaowei
    Li, Hao
    Yang, Yingxia
    Zhan, Binfei
    Zhao, Mingyang
    JOURNAL OF ENERGY STORAGE, 2022, 55
  • [6] Energy analysis of a solar-ground source heat pump system with vertical closed-loop for heating applications
    Bakirci, Kadir
    Ozyurt, Omer
    Comakli, Kemal
    Comakli, Omer
    ENERGY, 2011, 36 (05) : 3224 - 3232
  • [7] Assessment of installation suitability of a vertical closed loop ground source heat pump system in regional scale
    Shrestha, Gaurav
    Bando, Kazuro
    Ishihara, Takeshi
    Fujino, Takeshi
    Isoishi, Kosuke
    Tomigashi, Akira
    Uchida, Youhei
    GEOTHERMICS, 2023, 113
  • [8] Comparative Study on the Impact of Building Type and Location on the System Efficiency and Energy-Saving Potential of a Ground Source Heat Pump System
    Miao, Rui
    Yu, Yao
    Hu, Xiaoou
    ASHRAE TRANSACTIONS 2020, VOL 126, 2020, 126 : 192 - 205
  • [9] An Analysis of economical efficiency of closed-loop vertical ground source heat pump system applied in school
    Yang, Seung-Jin
    Park, Sang-Ho
    Kim, Ju-Young
    Hong, Won-Hwa
    6TH INTERNATIONAL SYMPOSIUM OF ASIA INSTITUTE OF URBAN ENVIRONMENT: ENERGY CONSERVATION AND CARBON OFF IN ASIA CITY, 2009, : 323 - 326
  • [10] Experimental study on the cooling operation characteristics of a closed loop vertical ground-coupled heat pump system
    Yang, W. B.
    Liu, G. Y.
    Shi, M. H.
    Chen, Z. Q.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 775 - 779