An integrated biosensor platform for extraction and detection of nucleic acids

被引:29
|
作者
Sciuto, Emanuele L. [1 ]
Petralia, Salvatore [2 ]
Calabrese, Giovanna [3 ]
Conoci, Sabrina [2 ,3 ]
机构
[1] CNR IMM, Catania, Italy
[2] STMicroelectronics, Stradale Primosole 50, I-95121 Catania, Italy
[3] Univ Messina, Dipartimento Sci Chim Biol Farmaceut & Ambientali, Messina, Italy
关键词
biosensors; extraction; microfluidics; nucleic acids; qRT-PCR; silicon chip; GENETIC DETECTION; REAL-TIME; POINT; REQUIREMENTS; DIAGNOSTICS; PATHOGENS;
D O I
10.1002/bit.27290
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The development of portable systems for analysis of nucleic acids (NAs) is crucial for the evolution of biosensing in the context of future healthcare technologies. The integration of NA extraction, purification, and detection modules, properly actuated by microfluidics technologies, is a key point for the development of portable diagnostic systems. In this paper, we describe an integrated biosensor platform based on a silicon-plastic hybrid lab-on-disk technology capable of managing NA extraction, purification, and detection processes in an integrated format. The sample preparation process is performed by solid-phase extraction technology using magnetic beads on a plastic disk, while detection is done through quantitative real-time polymerase chain reaction (qRT-PCR) on a miniaturized silicon device. The movement of sample and reagents is actuated by a centrifugal force induced by a disk actuator instrument. The assessment of the NA extraction and detection performance has been carried out by using hepatitis B virus (HBV) DNA genome as a biological target. The quantification of the qRT-PCR chip in the hybrid disk showed an improvement in sensitivity with respect to the qRT-PCR commercial platforms, which means an optimization of time and cost. Limit of detection and limit of quantification values of about 8 cps/reaction and 26 cps/reaction, respectively, were found by using analytical samples (synthetic clone), while the results with real samples (serum with spiked HBV genome) indicate that the system performs as well as the standard methods.
引用
收藏
页码:1554 / 1561
页数:8
相关论文
共 50 条
  • [31] Visual detection of nucleic acids based on lateral flow biosensor and hybridization chain reaction amplification
    Ying, Na
    Ju, Chuanjing
    Li, Zhongyi
    Liu, Wensen
    Wan, Jiayu
    TALANTA, 2017, 164 : 432 - 438
  • [32] Triple-Helix Molecular Switch Electrochemical Ratiometric Biosensor for Ultrasensitive Detection of Nucleic Acids
    Xiong, Erhu
    Li, Zhenzhen
    Zhang, Xiaohua
    Zhou, Jiawan
    Yan, Xiaoxia
    Liu, Yunqing
    Chen, Jinhua
    ANALYTICAL CHEMISTRY, 2017, 89 (17) : 8830 - 8835
  • [33] A new approach for the detection of DNA sequences in amplified nucleic acids by a surface plasmon resonance biosensor
    Wang, RH
    Minunni, M
    Tombelli, S
    Mascini, M
    BIOSENSORS & BIOELECTRONICS, 2004, 20 (03): : 598 - 605
  • [34] A novel hybrid biosensor for miRNA detection based on peptide nucleic acids and molecularly imprinted polymers
    Abdel-Hamied, Muhammed
    Guo, Min
    Wei, Yiming
    Bansmann, Joachim
    Nashar, Rasha M. El
    Oswald, Franz
    Mizaikoff, Boris
    Kranz, Christine
    BIOELECTROCHEMISTRY, 2025, 165
  • [35] Extraction of Total Nucleic Acids From Ticks for the Detection of Bacterial and Viral Pathogens
    Crowder, Chris D.
    Rounds, Megan A.
    Phillipson, Curtis A.
    Picuri, John M.
    Matthews, Heather E.
    Halverson, Justina
    Schutzer, Steven E.
    Ecker, David J.
    Eshoo, Mark W.
    JOURNAL OF MEDICAL ENTOMOLOGY, 2010, 47 (01) : 89 - 94
  • [36] Electrochemical Biosensor for PCR free Nucleic Acids Detection A novel biosensor containing three planar microelectrodes for melocular diagnostic applications
    Petralia, Salvatore
    Rundo, Francesco
    Conoci, Sabrina
    Di Pietro, Maria L.
    Sciuto, Emanuele L.
    Mirabella, Salvo
    2017 EUROPEAN CONFERENCE ON CIRCUIT THEORY AND DESIGN (ECCTD), 2017,
  • [37] An integrated microfluidic chip for nucleic acid extraction and continued cdPCR detection of pathogens
    Huang, Yaru
    Gao, Zehang
    Ma, Cong
    Sun, Yimeng
    Huang, Yuhang
    Jia, Chunping
    Zhao, Jianlong
    Feng, Shilun
    ANALYST, 2023, 148 (12) : 2758 - 2766
  • [38] Extraction of Nucleic Acids Comparison of automated and manual Extraction Methods from nucleic acid-based Detection Systems in the Food Laboratory
    Lorenzen, Erika
    DEUTSCHE LEBENSMITTEL-RUNDSCHAU, 2020, 116 (07) : 292 - 295
  • [39] Extraction of viral nucleic acids: Comparison of five automated nucleic acid extraction platforms
    Verheyen, Jens
    Kaiser, Rolf
    Bozic, Michael
    Timmen-Wego, Monika
    Maier, Barbara K.
    Kessler, Harald H.
    JOURNAL OF CLINICAL VIROLOGY, 2012, 54 (03) : 255 - 259
  • [40] Development of nucleic acid extraction and real-time recombinase polymerase amplification (RPA) assay integrated microfluidic biosensor for multiplex detection of foodborne bacteria
    Shang, Yuting
    Xing, Gaowa
    Lin, Haifeng
    Sun, Yucheng
    Chen, Shulang
    Lin, Jin-Ming
    FOOD CONTROL, 2024, 155