Long-term in vivo wear performance of porous-coated acetabular components sterilized with gamma irradiation in air or ethylene oxide

被引:10
|
作者
Orishimo, KF [1 ]
Hopper, RH [1 ]
Engh, CA [1 ]
机构
[1] Care of Janice Black, Anderson Orthopaed Res Inst, Alexandria, VA 22306 USA
来源
JOURNAL OF ARTHROPLASTY | 2003年 / 18卷 / 05期
关键词
total hip arthroplasty; polyethylene wear; long-term clinical outcome; time-dependent changes; MOLECULAR-WEIGHT POLYETHYLENE; TOTAL HIP-ARTHROPLASTY; LOW-FRICTION ARTHROPLASTY; GAS PLASMA; RADIOGRAPHIC EVALUATION; CLINICAL-PERFORMANCE; COBALT-CHROME; FEMORAL-HEAD; SHELF-LIFE; FOLLOW-UP;
D O I
10.1016/S0883-5403(03)00147-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study evaluated the long-term in vivo wear performance of 2 groups of well-functioning cementless acetabular cups sterilized by different methods. The first group included 31 hips that were implanted with AML TriSpike cups (DePuy, Warsaw, IN) sterilized by gamma-irradiation in air. The second group included 28 hips implanted with Arthropor cups (Joint Medical Products, Stamford, CT) that were sterilized with ethylene oxide. Time-dependent variations in the radiographic wear rates were compared within each group. Changes in the wear rates between 4- and 16-year follow-up times for the TriSpike cups were not significant (P=.09), and there was no evidence to suggest a trend toward substantially increasing wear rates with longer follow-up times. Among the Arthropor cups, the wear rates remained relatively constant between 2 and 14 years of follow-up evaluation. Although clinically apparent late increases in radiographic head penetration rates were not evident, we will continue to monitor all patients for evidence of accelerated wear at late follow-up.
引用
收藏
页码:546 / 552
页数:7
相关论文
共 23 条
  • [1] Clinical and radiographic results and wear performance in different generations of a cementless porous-coated acetabular cup
    E. García-Rey
    E. García-Cimbrelo
    International Orthopaedics, 2008, 32 : 181 - 187
  • [2] Clinical and radiographic results and wear performance in different generations of a cementless porous-coated acetabular cup
    Garcia-Rey, E.
    Garcia-Cimbrelo, E.
    INTERNATIONAL ORTHOPAEDICS, 2008, 32 (02) : 181 - 187
  • [3] Analysis of temporal wear patterns of porous-coated acetabular components: Distinguishing between true wear and so-called bedding-in
    Sychterz, CJ
    Engh, CA
    Yang, A
    Engh, CA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (06): : 821 - 830
  • [4] Long-term results of the cementless porous-coated anatomic total hip prosthesis
    Kim, YH
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (05): : 623 - 627
  • [5] Long-term results of porous-coated cementless total knee arthroplasty with screw fixation
    Azboy, Ibrahim
    Demirtas, Abdullah
    Bulut, Mehmet
    Ozturkmen, Yusuf
    Sukur, Erhan
    Caniklioglu, Mustafa
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2013, 47 (05) : 347 - 353
  • [6] Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old - Results at nine to fourteen years
    Crowther, JD
    Lachiewicz, PF
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (05): : 729 - 735
  • [7] Long-Term Results of Porous-Coated Anatomic Total Hip Arthroplasty for Patients With Osteoarthritis of the Hip
    Tezuka, Taro
    Inaba, Yutaka
    Kobayashi, Naomi
    Sato, Masaaki
    Mitsugi, Naoto
    Saito, Tomoyuki
    JOURNAL OF ARTHROPLASTY, 2014, 29 (12): : 2251 - 2255
  • [8] Extensively Porous-Coated Stems Demonstrate Excellent Long-Term Survivorship in Revision Total Hip Arthroplasty
    Dagneaux, Louis
    Sculco, Peter K.
    Haight, Holly J.
    Larson, Dirk R.
    Howard, James L.
    Abdel, Matthew P.
    Berry, Daniel J.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (07): : S217 - S222
  • [9] Rapid polyethylene failure of unicondylar tibial components sterilized with gamma irradiation in air and implanted after a long shelf life
    McGovern, TF
    Ammeen, DJ
    Collier, JP
    Currier, BH
    Engh, GA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (06): : 901 - 906
  • [10] Long-Term Results of Revision Total Hip Arthroplasty Using a Modern Extensively Porous-Coated Femoral Stem
    Wallace, Charles N.
    Chang, Justin S.
    Kayani, Babar
    Moriarty, Peter D.
    Tahmassebi, Jenni E.
    Haddad, Fares S.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (12): : 3697 - 3702