Sterilization of rotary NiTi instruments within endodontic sponges

被引:4
|
作者
Chan, H. W. A. [1 ]
Tan, K. H. [1 ,2 ]
Dashper, S. G. [1 ,2 ]
Reynolds, E. C. [1 ,2 ]
Parashos, P. [1 ]
机构
[1] Univ Melbourne, Melbourne Dent Sch, 720 Swanston St, Melbourne, Vic 3010, Australia
[2] Univ Melbourne, Oral Hlth Cooperat Res Ctr, Melbourne, Vic, Australia
关键词
autoclave; bacteria; infection; NiTi instrument contamination; rubber stoppers; sterilization; PORPHYROMONAS-GINGIVALIS; ENTEROCOCCUS-FAECALIS; SURGICAL-INSTRUMENTS; FILES; DECONTAMINATION; INFECTIONS; SURFACES; DEBRIS;
D O I
10.1111/iej.12521
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To determine whether the following can be sterilized by autoclaving - endodontic sponges, rotary nickel-titanium (NiTi) instruments within endodontic sponges, and rotary NiTi instruments with rubber stoppers. Methodology Sixty-four samples of eight different endodontic sponges (n = 512) were placed into brain heart infusion broth (BHI) for 72 h. An aliquot of this was then spread onto horse blood agar and cultured aerobically and anaerobically to test sterility at purchase. Bacterial suspensions of Enterococcus faecalis, Porphyromonas gingivalis and Geobacillus stearothermophilus in BHI were used to contaminate sterile sponges and rotary NiTi instruments (with and without rubber stoppers) inserted into sponges. The various samples were autoclaved and then cultured aerobically and anaerobically. Success of sterilization was measured qualitatively as no growth. The experiment was repeated with clinically used rotary NiTi instruments (n = 512). All experiments were conducted in quadruplicate. Results No sponges on purchase had microbial growth when anaerobically cultured but some did when aerobically cultured. All autoclaved sponges and instruments (within or without sponges, and with or without rubber stoppers) were associated with no microbial growth. All nonautoclaved positive control samples showed microbial growth. Conclusions Autoclaving was effective in the sterilization of sponges and endodontic instruments. Endodontic sponges should be autoclaved before clinical use. For clinical efficiency and cost-effectiveness, rotary NiTi instruments can be sterilized in endodontic sponges without removal of rubber stoppers.
引用
下载
收藏
页码:850 / 857
页数:8
相关论文
共 50 条
  • [41] A cleaning protocol for rotary nickel-titanium endodontic instruments
    Parashos, P
    Linsuwanont, P
    Messer, HH
    AUSTRALIAN DENTAL JOURNAL, 2004, 49 (01) : 20 - 27
  • [42] Cyclic fatigue testing of new and used NiTi rotary instruments
    Pompa, G
    Gambarini, G
    Pongione, G
    Floridi, G
    Di Carlo, F
    De Luca, M
    Quaranta, M
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 440 - 440
  • [43] Enhancement of NiTi superelastic endodontic instruments by TiO2 coating
    Aun, Diego Pinheiro
    da Cunha Peixoto, Isabella Faria
    Houmard, Manuel
    Lopes Buono, Vicente Tadeu
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 68 : 675 - 680
  • [44] Evaluation of biological debris on endodontic instruments after cleaning and sterilization procedures
    Popovic, J.
    Gasic, J.
    Zivkovic, S.
    Petrovic, A.
    Radicevic, G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (04) : 336 - 341
  • [45] Impact of endodontic irrigants on surface roughness of various nickel-titanium rotary endodontic instruments
    Hamdy, Tamer M.
    Alkabani, Yasmine Mohsen
    Ismail, Amira Galal
    Galal, Manar M.
    BMC ORAL HEALTH, 2023, 23 (01)
  • [46] Impact of endodontic irrigants on surface roughness of various nickel-titanium rotary endodontic instruments
    Tamer M. Hamdy
    Yasmine Mohsen Alkabani
    Amira Galal Ismail
    Manar M. Galal
    BMC Oral Health, 23
  • [47] Comparison of root canal preparation with two rotary NiTi instruments:: ProFile .04 and GT Rotary
    Roedig, T.
    Huelsmann, M.
    Kahlmeier, C.
    INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (07) : 553 - 562
  • [48] Fracture resistance of electropolished rotary nickel-titanium endodontic instruments
    Anderson, Margot E.
    Price, John W. H.
    Parashos, Peter
    JOURNAL OF ENDODONTICS, 2007, 33 (10) : 1212 - 1216
  • [49] Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic files
    Rapisarda, E
    Bonaccorso, A
    Tripi, TR
    Condorelli, GG
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 88 (03): : 343 - 347
  • [50] Cyclic fatigue of NiTi rotary instruments in a simulated apical abrupt curvature
    Plotino, G.
    Grande, N. M.
    Melo, M. C.
    Bahia, M. G.
    Testarelli, L.
    Gambarini, G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (03) : 226 - 230