The association between intravascular ultrasound-derived echo-attenuation and quantitative flow ratio in intermediate coronary lesions

被引:1
|
作者
Geng, Liang [1 ,2 ]
Yuan, Yuan [3 ]
Du, Peizhao [4 ]
Gao, Liming [1 ]
Wang, Yunkai [1 ]
Li, Jiming [1 ]
Guo, Wei [1 ]
Huang, Ying [1 ]
Zhang, Qi [1 ]
机构
[1] Tongji Univ, Shanghai East Hosp, Sch Med, Dept Cardiol, Shanghai 200092, Peoples R China
[2] JIan Hosp, Shanghai East Hosp, Dept Cardiol, Jian, Jiangxi, Peoples R China
[3] Putuo Dist Peoples Hosp, Dept Cardiol, Shanghai, Peoples R China
[4] Baoshan Hosp Integrated Tradit Chinese & Western, Dept Cardiol, Shanghai, Peoples R China
关键词
Coronary artery disease; intermediate coronary lesion; quantitative flow ratio (QFR); intravascular ultrasound (IVUS); echo-attenuation; PLAQUE; ANGIOGRAPHY; RESERVE; CALCIFICATION; INTERVENTION; MORPHOLOGY; ACCURACY; STENOSIS; IMPACT;
D O I
10.21037/cdt-21-402
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The clinical relevance of moderate coronary stenosis is determined by its morphological characteristics and physiological significance. We investigated the relationship between high-risk plaque characteristics detected by intravascular ultrasound and functional significance assessed with quantitative flow ratio (QFR) in intermediate coronary lesions. Methods: QFR was retrospectively analyzed in 352 intermediate lesions from 330 patients undergoing intravascular ultrasound examination. The functional significance was defined as QFR 50.8. High-risk plaque morphologies including plaque rupture, echo-lucent, echo-attenuation, and spotty calcification were identified, and attenuation indices including maximum angle, attenuation length, and superficial attenuation were determined. Clinically relevant echo-attenuation was defined as an attenuation with a minimum lumen area 54.0 mm(2) and plaque burden >= 70%. Results: The prevalence of echo-attenuation was higher (63.0% vs. 37.6%, P=0.001) and attenuation length was longer (12.8 +/- 10.3 vs. 8.0 +/- 5.8 mm, P=0.015) in lesions with QFR 50.8 compared to those with QFR >0.8, associated with a higher rate of clinically relevant echo-attenuation (35.2% vs. 10.4%, P<0.001). On multivariable analysis, the presence of echo-attenuation was an independent predictor of QFR 50.8 [odds ratio (OR) 3.162, 95% confidence interval (CI): 1.263-7.917, P=0.014], whereas attenuation length was weakly correlated with QFR value (beta=-0.185, B=-0.002, 95% CI: -0.004 to -0.001, P=0.001). Receiver operating characteristic curve analysis revealed that the best cutoff of QFR in predicting clinically relevant echo-attenuation was 0.82 [area under the curve (AUC) =0.696, 95% CI: 0.616-0.775, P<0.001]. Conclusions: The presence of intravascular ultrasound-derived echo-attenuation confers an increased risk of QFR-defined functional significance in intermediate coronary lesions.
引用
收藏
页码:1206 / 1216
页数:11
相关论文
共 50 条
  • [31] Correlation Between Fractional Flow Reserve and Intravascular Ultrasound Lumen Area in Intermediate Coronary Artery Stenoses
    Ben-Dor, Itsik
    Torguson, Rebecca
    Gaglia, Michael A.
    Gonzalez, Manuel A.
    Maluenda, Gabriel
    But, Anh B.
    Angelo, Manuel J.
    Syed, Asmir I.
    Wakabayashi, Kohei
    Weissman, Gaby
    Xue, Zhenyi
    Satler, Lowell F.
    Suddath, William O.
    Kent, Kenneth M.
    Lindsay, Joseph
    Pichard, Augusto D.
    Waksman, Ron
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (13) : B96 - B96
  • [32] Clinical potential of intravascular ultrasound for physiological assessment of coronary stenosis - Relationship between quantitative ultrasound tomography and pressure-derived fractional flow reserve
    Takagi, A
    Tsurumi, Y
    Ishii, Y
    Suzuki, K
    Kawana, M
    Kasanuki, H
    CIRCULATION, 1999, 100 (03) : 250 - 255
  • [33] Letter by Layland et al Regarding Article, "Validation of Intravascular Ultrasound-Derived Parameters With Fractional Flow Reserve for Assessment of Coronary Stenosis Severity"
    Layland, Jamie
    Wilson, Andrew
    Whitbourn, Robert
    MacIsaac, Andrew
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (03) : E16 - E16
  • [34] Accuracy of coronary computed tomography angiography-derived quantitative flow ratio for onsite assessment of coronary lesions
    Weng, Tingwen
    Ding, Daixin
    Li, Guanyu
    Guan, Shaofeng
    Han, Wenzheng
    Gan, Qian
    Li, Ming
    Qi, Lin
    Li, Cheng
    Chen, Yang
    Zhang, Liang
    Li, Tianqi
    Chang, Xifeng
    Chen, Yankai
    Wijns, William
    Qu, Xinkai
    Tu, Shengxian
    EUROINTERVENTION, 2024, 20 (20)
  • [35] Assessment of intermediate coronary lesions by fractional flow reserve and quantitative flow ratio in patients with small-vessel disease
    Erbay, Aslihan
    Steiner, Julia
    Lauten, Alexander
    Landmesser, Ulf
    Leistner, David M.
    Staehli, Barbara E.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 96 (04) : 743 - 751
  • [36] Assessment of intermediate coronary lesions by fractional flow reserve and quantitative flow ratio in patients with small-vessel disease
    Erbay, A.
    Steiner, J.
    Lauten, A.
    Landmesser, U.
    Leistner, D.
    Stahli, B. E.
    EUROPEAN HEART JOURNAL, 2018, 39 : 948 - 948
  • [37] Intracoronary ultrasound assessment of intermediate coronary lesions: Comparison with pressure-derived fractional flow reserve
    Legutko, J
    Dudek, D
    Zmudka, K
    Dubiel, JS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 23A - 24A
  • [38] Intravascular ultrasound and ultrasonic flow ratio-guided zero-contrast rotational atherectomy for calcified coronary lesions
    Chen, Tao
    Zhou, Hang
    Guo, Jun
    Chen, Yundai
    EUROPEAN HEART JOURNAL, 2023, 44 (02) : 166 - 166
  • [39] INTRAVASCULAR ULTRASOUND-DERIVED VIRTUAL FRACTIONAL FLOW RESERVE TO PREDICT 3-YEAR OUTCOMES OF UNTREATED NON-CULPRIT LESIONS: THE PROSPECT STUDY
    Seike, Fumiyasu
    Mintz, Gary
    Matsumura, Mitsuaki
    Ali, Ziad
    Liu, Mengdan
    Ben-Yehuda, Ori
    De Bruyne, Bernard
    Serruys, Patrick
    Yasuda, Kazunori
    Stone, Gregg
    Maehara, Akiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1119 - 1119
  • [40] Discordance between quantitative coronary angiography and fractional flow reserve or intravascular ultrasound: a substudy of the FLAVOUR trial
    Lee, J. H.
    Jeon, H. S.
    Lee, J. W.
    Youn, Y. J.
    Ahn, S. G.
    Kang, J. H.
    Koo, B. K.
    EUROPEAN HEART JOURNAL, 2023, 44